33015

$883.05
Special Order-Generally ships in 14 to 21 Business Days
SKU
33015

6 Crimp lugs - for copper cable 300mm2 - for Masterpact NT NS630b..1600

Main
Poles description
3P
Quantity per set
Set of 6
[In] rated current
1600 A
Device short name
Crimp lugs
Accessory / separate part category
Connection accessory
Range compatibility
Compact Compact NS630b...1600

Masterpact Masterpact NT
Offer type
C4
Complementary
Mounting mode
Fixed

Drawout
Location of connection
Front

Rear
Connections - terminals
Cable connector 300 mm²
Accessory / separate part category
Spare part Compact NS630b...1600
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:33015

   Frequently Asked Questions and Answers


  • Is it necessary to use the protection shield on the top side of the Compact NS>630 if the breaker is mounted in horizontal position.

    The white protection shield at the top side of the breaker is for protection and isolation of the bare cable connectors against gas exhaust.   Hence it is always necessary to use protection shield irrespective of the breaker mounting position.   Note: It is not necessary at the down side because the hot gas exhaust is always from the top.
    Read more

  • How to connect the Vigi Module with Compact NS MCCB?

    Refer the Vigi Installation Guide for the instruction to connect the Vigi module on the Compact NS Moulded Case Circuit Breaker (MCCB). Caution: Before adapting the Vigi module on Compact NS MCCB, exchange the downstream nuts of the MCCB and the downstream nuts of the Vigi Module. Refer page 3, figure 2 of attachment. Vigi Installation.pdf
    Read more

  • In Compact NS circuit breakers is it possible to install M2C programmable contacts?

    The M2C programmable contacts are not compatible for installation in Compact NS circuit breaker. For signalization the I/O module can be considered, or the M6C contact with Micrologic P.
    Read more

  • Does Compact NS/NSX Switch Disconnector (NA) have the Reflex Tripping.

    Yes, Reflex Tripping is available in all Compact NS/NSX Switch Disconnectors. The threshold of the Reflex Tripping auto-protection is about 20xIn and time delay is less than 10 ms, as shown in the attached tripping curves. The Reflex Tripping is due to \'Piston - which is purely mechanical” and not due to the trip unit.   Thus the Reflex Tripping being a mechanical controlled function is also available in the Compact NS/NSX Switch Disconnectors. Reflex Tripping Curve.pdf
    Read more

  • How can I obtain the manufacturing date of the Compact NS or NSX circuit-breakers ?

    To obtain the manufacturing date of Compact NS or NSX circuit-breakers, read the screen-printed marking at the top of the front panel. The code P07351, for example, provides the following information:   The 1st letter corresponds to the manufacturing site: P (Montmélian in France), PL (Poland) or N (Naples) The next 2 numbers correspond to the year: 2007 in this example The next 2 numbers correspond to the week: week 35 in this example Finally the last number corresponds to the day of the we...
    Read more

User guide
  • file image Guide d'exploitation Masterpact NT06-16 CEI (pdf) download image`
  • file image User manual Masterpact NT06-16 IEC (pdf) download image`
Catalogue
  • file image Catalogue COMPACT NS 630b to 3200A Circuit breakers and switch-disconnectors (pdf) download image`
Instruction sheet
  • file image Masterpact NT: Circuit-Breaker accessories (pdf) download image`
  • file image Compact NS630b-1600 : Fixed and withdrawable remote control Circuit-Breaker + Accessories (pdf) download image`
  • file image Compact NS630b-1600 : Fixed and withdrawable Circuit-Breaker + Accessories (pdf) download image`
  • file image Fixed and drawout circuit breaker - Masterpact NT (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech