H723LC
Current Sensor: 0-10 VDC Output, 0-10/20/40 Amperage Range, Solid-Core Housing, CE
H923
Current Sensor: 0-10 VDC Analog Output, 0-20/100/150A field selectable Amp Range, Split-Core Housing, CE
H723HC
Current Sensor: 0-10 VDC Output, 0-50/100/200 Amperage Range, Solid-Core Housing, CE
H822
Current Sensor: 0-5VDC Analog Output, 0-10 Amerage Range, Solid-Core Housing, UL Listed, RoHS Compliant
H822-20
Current Sensor: 0-5VDC Analog Output, 0-20 Amperage Range, Solid Core Housing, UL Listed, RoHS Compliant
H922
Current Sensor: 0-5VDC Analog Output, 0-30/60/120A field selectable Amp Range, Split-Core Housing, UL Listed for use on 75 deg. C insulated conductors
H722HC
Current Sensor: 0-5VDC Analog Output, 0-50/100/200 Amperage Range, Solid-Core Housing, UL Listed, CE
H721LC
Current Sensor: 4-20mA Analog Output, 0-10/20/40 Amperage Range, Solid-Core Housing, UL Listed, CE
H921
Current Sensor: 4-20mA Analog Output, 0-30/60/120A field selectable Amp Range, Split-Core Housing, UL Listed for use on 75 deg. C insulated conductors
H721HC
Current Sensor: 4-20mA Analog Output, 0-50/100/200 Amperage Range, Solid-Core Housing, UL Listed, CE
H421
Current Sensor: 4-20mA Loop Powered Output, Split-Core, 1000 to 2400 Amps, Split-Core Housing, RoHS Compliant
$1,092.87 inc GST
Buy Now
H221
Current Sensor: 4-20mA Loop Powered Output, Split-Core, 100-300 Amps, UL Listed for use on 75 deg. C insulated conductors, CE, RoHS Compliant
H748
Current Switch w/Relay: Adjustable Trip Point, 1-135 Amp, 1.0A@30VAC/DC, 1A or less Min Trip Point, SPDT, 24VAC/DC, Solid-Core, Relay Power LED
H758
Current Switch w/Relay: Adjustable Trip Point, 1-135 Amp, N.O. 1.0A@30VAC/DC, 1A or less, SPST, 12 VDC nom., Solid-Core, Status LED, Relay Power LED
H730
Current Switch w/Relay: Fixed Trip Point, 0.5 - 200 Amp Range, Normally Open 1.0A@30VAC/DC, 0.5A or less Minimum Trip Point, Solid-Core Housing, LED
H930
Current Switch w/Relay: Fixed Trip Point, 1.5-200 Amp, N.O. 1.0A@30VAC/DC, 1.5A or less Fixed Trip Point, SPST, N.O. Relay, 24VAC/DC Relay Coil
H608
Current Switch: Adjustable Trip Point, 0.5-175 Amp Range, Normally Open 1.0A@30VAC/DC, 0.5A or less Minimum Trip Point, Split-Core Housing, Status LED
H308
Current Switch: Adjustable Trip Point, 0.75 - 50 Amp Range, Normally Open 1.0A@30VAC/DC, 0.75A or less Minimum Trip Point, Split-Core Housing