TM3SAF5R

$713.86
Special Order-Generally ships in 14 to 21 Business Days
SKU
TM3SAF5R

SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS

Main
Range of product
Modicon TM3 Safety
Product or component type
Safety module
Device short name
TM3SAF
Safety module application
For emergency stop and switch monitoring
Function of module
Emergency stop monitoring 1-channel wiring

Emergency stop monitoring 2-channel wiring

Monitoring of a movable guard with 2 switches and automatic start
Safety level
Can reach PL e/category 4 EN/ISO 13849-1:2008

Can reach PL e/category 4 EN/ISO 13849-2:2012

Can reach SILCL 3 EN/IEC 62061:2005

Can reach SIL 3 EN/IEC 61508:2010
Complementary
Input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
Cable distance between devices
30 m
Breaking capacity
360 VA holding AC-15 B300 relay output

3600 VA inrush AC-15 B300 relay output
Breaking capacity
4 A 24 V 50 ms DC-13 relay output
Output thermal current
6 A per relay relay output
[Ith] conventional free air thermal current
18 A
Associated fuse rating
4 A gG or gL relay output EN/IEC 60947-5-1

6 A fast blow relay output EN/IEC 60947-5-1
Minimum output current
10 mA relay output
Output voltage
10 V relay output
Response time on input open
<= 40 ms
[Ui] rated insulation voltage
300 V 2 IEC 60647-5-1
[Uimp] rated impulse withstand voltage
4 kV III IEC 60647-5-1
Current consumption
100 mA 24 V DC external supply
Local signalling
8 LEDs green/red user
Electrical connection
Screw terminal
Standards
EN/ISO 13849-1:2008

EN/ISO 13849-2:2012

EN/IEC 62061:2005

EN/IEC 61508:2010

EN/IEC 60947-5-1:2010

EN/IEC 61131-2:2007

EN/IEC 60204-1:2005

EN/IEC 60204-1:2009/A1

IEC 61010-1:2010

EN 50581:2012
Product certifications
TÜV

RCM

EAC

UL 61010-2-201

CSA 61010-2-201 (pending)

ANSI Haz Loc Class 1 Division 2 (pending)

CSA Haz Loc Class 1 Division 2 (pending)
Marking
CE

CSA

UL

EFUP 10

REACH

TÜV

EAC

RCM
Electromagnetic compatibility
Electrostatic discharge immunity test 8 kV air discharge conforming to EN/IEC 61000-4-2

Electrostatic discharge immunity test 6 kV contact discharge conforming to EN/IEC 61000-4-2

Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3

Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3

Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3

Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8

Electrical fast transient/burst immunity test 3 kV power lines (DC) conforming to EN/IEC 61000-4-4

Electrical fast transient/burst immunity test 2 kV I/O conforming to EN/IEC 61000-4-4

1.2/50 µs shock waves immunity test 1 kV power lines (DC) conforming to EN/IEC 61000-4-5

Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6

Radiated emission 40 dBµV/m class A 24 V conforming to EN 55011

Radiated emission 47 dBµV/m class A 24 V conforming to EN 55011
Mounting support
Wall mount using attached fasteners

Rail top hat type TH35-7.5 IEC 60715

Rail top hat type TH35-15 IEC 60715
Height
94 mm
Depth
73 mm
Width
43.7 mm
Product weight
0.19 kg
Safety reliability data
DC = 95 % EN/ISO 13849-1

PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A

PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A

MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A

MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A

SFF = 95 % IEC 61508-1

HFT = 1 IEC 61508-1

Type = A IEC 61508-1
Synchronisation time between inputs
Unlimited
Connections - terminals
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34

Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals

Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals

Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Output type
Relay instantaneous opening 3 NO potential free
Number of safety circuits
3 NO (relay instantaneous opening)
Maximum switching voltage
230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)

24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage
24 V DC - 15...20 %
Power consumption in W
0.2 W 5 V DC

3.6 W 24 V DC
Environment
Standards
EN 1088/ISO 14119

EN 60204-1

EN/IEC 60947-1

EN/IEC 60947-5-1

EN/ISO 13850
Resistance to electrostatic discharge
6 kV on contact EN/IEC 61000-4-2

8 kV in air EN/IEC 61000-4-2
Resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3

3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3

1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3
Resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Resistance to fast transients
3 kV power lines (DC) EN/IEC 61000-4-4 DC

2 kV I/O lines EN/IEC 61000-4-4
Surge withstand
1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC

1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC
Resistance to conducted disturbances
10 V 0.15...80 MHz EN/IEC 61000-4-6
Electromagnetic emission
Radiated emissions 50 dBµV/m class A 24 V DC 30...230 Hz IEC 61131-3

Radiated emissions 57 dBµV/m class A 24 V DC 230...1000 Hz IEC 61131-3
Ambient air temperature for operation
-10...55 °C horizontal installation
Ambient air temperature for storage
-25...70 °C
Relative humidity
10...95 % without condensation in operation

10...95 % without condensation in storage
IP degree of protection
IP20 EN/IEC 60529 terminals
Pollution degree
2
Operating altitude
0...2000 m
Storage altitude
0...3000 m
Vibration resistance
+/- 3.5 mm 5...150 Hz IEC 60068-2-6
Shock resistance
15 gn 11 ms IEC 60068-2-27
Mechanical robustness
Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Write Your Own Review
You're reviewing:TM3SAF5R

   Frequently Asked Questions and Answers


  • Can I disable a TM3 module in SoMachine?

    Issue: Set the TM3 module as optional in SoMachine Product Line: Modicon TM3 Resolution: It's possible to set a TM3 module as optional in SoMachine. This will allow you to run your program without faulting the TM3 bus even if the TM3 module is not physically present on the rack.  See attached screenashot for how to do that in SoMachine.  TM3.png
    Read more

  • What is the maximum number of expansion modules for M221 controllers

    Local I/O Maximum configuration: 7 Modicon TM3 expansion modules associated with an M221 logic controller. Depending on the expansion module references, there may be fewer than 7. Remote I/O Maximum configuration: 14 Modicon TM3 expansion modules (7 local modules + 7 remote modules) with the Modicon TM3 bus expansion system (transmitter module and receiver module is not included in the maximum number of modules). TM3 expansion modules are powered by logic controllers via the bus connector on the side ...
    Read more

  • Reverse PID mode in Modicon M241/M251

    There is no input to select between direct/inverse direction at the PID function block from the Util library. The FB_PID function block (Toolbox library) is from Schneider and has additional features. With FB_PID function block from the Toolbox library in SoMachine to change the regulation direction user can use negative P-factor (i_rKp) The basic PID function must remain the same.
    Read more

  • Can we use 800 IOs with Modicon m580 Safety System without impact TUV certification

    There is no issue to use 800 series IOs without any impact on TÜV certificate on a M580 Safety configuration. As a general rule, all of Remote Distributed equipments on Ethernet allowed in M580 system could be considered as “non-interfering” for Safety M580 modules. However, of course, 800 series IOs data are not supposed to be used to perform safety functions.
    Read more

  • Video: Setting Persistent Variables with the Modicon M221 in SoMachine Basic

    The video demonstrates how to set up persistent variables and save them in the memory words of SoMachine Basic.  
    Read more

User guide
  • file image Modicon TM3 - Safety Modules, Hardware Guide (pdf) download image`
  • file image Modicon TM3 - Expansion Modules, Programming Guide (pdf) download image`
  • file image SoMachine Basic - Operating guide (pdf) download image`
Catalogue
  • file image Modicon TM3 I/O expansion modules for Modicon controllers (pdf) download image`
Instruction sheet
  • file image TM3SAF5R, TM3SAF5RG TM3 Safety Modules, Instruction Sheet (pdf) download image`
  • file image TM3SAF5R, TM3SAF5RG TM3 Safety Modules, Instruction Sheet (pdf) download image`
Certificate
  • file image EC_TypeExamination_Certificate_TUEVNORD (pdf) download image`
  • file image UL Certificate TM3 Safety (FS) (pdf) download image`
  • file image CSA Certificate TM3 Safety (pdf) download image`
  • file image UL Certificate TM3 Safety (pdf) download image`
Declaration of conformity
  • file image Modicon DoC TM3 Safety (pdf) download image`
  • file image Modicon DoC TM3 Accessory (pdf) download image`
End of life manual
  • file image TM3... Safety Module, Product End-of-Life Instructions (pdf) download image`
Product environmental
  • file image TM3... Safety Module, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS (pdf) download image`
RoHs Declaration
  • file image SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS (pdf) download image`

Dimensions Drawings

Dimensions



(*)
8.5 mm/0.33 in when the clamp is pulled out.


Mounting and Clearance

Spacing Requirements





Mounting on a Rail



Incorrect Mounting





Mounting on a Panel Surface



(1)
Install a mounting strip
Mounting Hole Layout





Connections and Schema

Emergency Stop Wiring Diagram



S1 :
Emergency stop switch
S2 :
Start switch
(1)
Safety outputs
(2)
Monitored start
(3)
Non-monitored start
(4)
For automatic start, directly connect [S33] and [S39] terminals
(5)
Second external device monitoring channel. Connect [S41] and [S42] terminals if not used
(6)
Fuses. Refer to technical specifications for fuse values
(7)
Non-safety related TM3 Bus communication with logic controller


Protective Guard Wiring



(1)
Protective guard