SKU:

MTZ225H15X3PMD

Circuit breaker, MasterPact MTZ2 25H1 (66kA/415VAC), 3P, 2500A, drawout, manually operated, MicroLogic 5.0X control unit

Old price: $29,304.00 INC GST
$23,443.20 INC GST
Available for Shipping : 07-Jan-2026
Circuit breaker, MasterPact MTZ2 25H1 (66kA/415VAC), 3P, 2500A, drawout, manually operated, MicroLogic 5.0X control unit
  • Enhanced performance and connectivity with MasterPact MTZ
  • Available from 630A up to 6300A rated current
  • MasterPact MTZ is completely integrated in EcoStruxure Power architectures
  • Enhanced sustainability with Green Building certification and Green Premium compliancy
  • Easy installation using established architectures
  • Intuitive EcoStruxure Power Device smartphone app for easy operation and maintenance
  • Precise Class 1 metering built in for energy saving capabilities
  • Intuitive MicroLogic X control unit
  • Easy customization of MicroLogic control units with digital modules
  • Designed and tested to applicable standards for IEC, ANSI and UL
Manufacturer: Schneider Electric
Delivery date: 07-Jan-2026
This device is a complete 3 poles circuit breaker MasterPact MTZ2 25H1 in withdrawable version (drawout), equipped with a MicroLogic 5.0X control unit. MasterPact MTZ is the last generation of high current air circuit breakers from 630A up to 6300A, embedding advanced digital technologies. The operational current rating (In) is 2500A. The breaking capacity (Icu) is 66kA at 415VAC 50/60Hz (H1 performance level). It is manually operated (there is no integrated motor mechanism). It is equipped with a 3 poles chassis for drawout version. MicroLogic 5.0X is an electronic control unit with an adjustable long time protection against overloads (ANSI 49RMS/51). It embeds as well adjustable short-time protection (ANSI 50TD/51) and instantaneous protection (ANSI 50) against short-circuits. The information processed by the MicroLogic 5.0X may be displayed on its embedded HMI, or on a smartphone using EcoStruxure Power device application. Protections can be set with the embedded display, a smartphone or with a PC and additionally via Ethernet and Modbus SL communication, using EcoStruxure softwares. It is possible to customize MicroLogic X control unit anytime with digital modules to add new protection, measurement or diagnosis functionalities. MicroLogic X control units incorporate several channels of communication, including Ethernet, Modbus SL and wireless communication facilities. Power connection is made through rear horizontal connections for the top side and rear vertical connections for the bottom side. There are four OF auxiliary contacts (ON/OFF breaker status), 1 SDE auxiliary contact (fault trip indication) and 1 PF auxiliary contact (ready to close indication). An ULP port module is part of the configuration and mounted on the chassis enabling connection with Ethernet or Modbus communication modules. The dimensions are 439mm (H) x 441mm (W) x 403mm (D). It ensures compliance with international standards IEC 60947-1 and IEC60947-2. MasterPact MTZ circuit breakers prepare you for the future of power distribution with smart connectivity, remote monitoring, and easy customization via digital modules. MasterPact MTZ is the first air circuit breaker with built-in, third party certified Class 1 active power meter (IEC 61557-12). MasterPact MTZ circuit breaker is integrated in EcoStruxure Power architecture enabling valuable data generation. MasterPact MTZ allows you to stay connected and avoid downtime using the smartphone EcoStruxure Power Device App and EcoStruxure softwares. MasterPact MTZ is a Green Premium product, and helps to enhance sustainability by reducing CO2 emissions, utility and operating costs.

Products specifications

Attribute name Attribute value
Main
Device application distribution
Suitability for isolation yes conforming to EN/IEC 60947-2
Trip unit technology electronic
Utilisation category category B
Device short name MTZ2 25 H1
Breaking capacity code H1 66 kA 415 V AC
Mounting mode drawout
Control type ON/OFF push-button, manually operated
Range MasterPacT
Protected poles description 3D
Range of product MasterPact MTZ2
Trip unit name MicroLogic 5.0 X
Poles description 3P
Product name MasterPact MTZ2
Product or component type circuit breaker
Trip unit protection functions LSI
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[In] rated current 2500 A at 40 °C
Complementary
[Isd] short-time pick-up adjustment range 1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
Provision for padlocking 3 padlocks
[Uimp] rated impulse withstand voltage 12 kV conforming to EN/IEC 60947-2
Energy management measurement ,energy (standard), measurement ,electrical network (standard), measurement ,active, reactive and apparent energy (standard)
Trip unit rating 2500-2500 A at 40 °C
Width 422 mm
Measurement accuracy current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A, current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A, current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A, reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %, active power P, P1, P2, P3, Pdemand: +/- 1 %, apparent power S, S1, S2, S3, Sdemand: +/- 1 %, voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V, voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V, frequency: +/- 0.005 Hz, unbalance current: +/- 0.5 %, apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh, reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh, active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh, power factor: +/- 1 %
Electrical durability 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2, 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Commissioning interface EcoStruxure Power Commission
Depth 300 mm
Zone selective interlocking ZSI with
Display type LCD display - 128 x 96 pixels
Communication port protocol USB peer to peer 115 kbauds, NFC peer to peer 28800 bauds conforming to ISO 15963, Bluetooth 4.0 LE peer to peer 30 kbit/s conforming to IEEE 802.15.1
Downside connection vertical, rear
Locking options description keylock in OFF position, padlock in OFF position
Earth-leakage protection without
Thermal memory yes
[Ics] rated service breaking capacity 66 kA at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Accuracy class class 2: total voltage harmonic distortion THD (V), class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h), class 0.5: unbalance voltage, class 5: total current harmonic distortion THD (I)
End user smartphone application EcoStruxure Power Device
Data recording data logs, time stamping, event logs, maintenance logs, alarm logs, min/max of instantaneous values
Mechanical durability 20000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to EN/IEC 60947-2
[tsd] short-time delay adjustment range 0-0.4 s I²t=off, 0.1-0.4 s I²t=on
[tr] long-time delay adjustment range 0.34-16.6 s at 7.2 x Ir, 0.5-24 s at 6 x Ir, 12.5-600 s at 1.5 x Ir
Maximum closing response time 70 ms
Net weight 90 kg
Maximum breaking time 25-25 ms
Long time delay adjustment type adjustable in step of 0.5 s
Power dissipation per pole 600 W
[Icw] rated short-time withstand current 66 kA 3 s conforming to EN/IEC 60947-2, 66 kA 1 s conforming to EN/IEC 60947-2, 66 kA 0.5 s conforming to EN/IEC 60947-2
Protection type short time short-circuit protection conforming to ANSI 51, instantaneous short-circuit protection conforming to ANSI 50, overload protection (long time) conforming to ANSI 49
Connection pitch 115 mm
Breaking capacity 66 kA Icu at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA Icu at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 66 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Upside connection horizontal, rear
Operating time 20...50 ms in standard
Instantaneous pick-up adjustment range Ii enable on/off, 2...15 x In adjustable in step of 0.5 x In with embedded HMI
Short-time delay adjustment type adjustable
Metering type demand power P, Q, S standard), demand current I1, I2, I3, In, Iavg standard), total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard), total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard), voltage V21, V32, V13, V1, V2, V3: maximum standard), voltage V21, V32, V13, V1, V2, V3: minimum standard), voltage V21, V32, V13, V1, V2, V3: instantaneous standard), total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard), total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard), frequency standard), power factor standard), apparent power S, S1, S2, S3 standard), reactive power Q, Q1, Q2, Q3 standard), active power P, P1, P2, P3 standard), average voltage Vavg standard), current I1, I2, I3, In, Ig: maximum standard)
Frequency measurement range 45-250 Hz
Network and machine diagnosis type breaker service life: circuit breaker health state standard), operation: advanced diagnostic standard), trip context information: crisis management standard), selectivity test: test standard), protection test: test standard), MicroLogic test: test standard), operation: diagnostic data standard), monitored function: diagnostic data standard), configured alarms synthesis: diagnostic data standard), identification card: diagnostic data standard), tripping cause indication: circuit breaker tripping cause standard), MicroLogic service life: circuit breaker health state standard), contacts state: circuit breaker health state standard), system (HMI) health state overview: circuit breaker health state standard)
Local signalling 1 LED (red/orange) for service, 1 LED (green) for ready to operate, 1 LED (red/orange) for overload, 3 LEDs (red) for trip causes
Height 352 mm
[Icm] rated short-circuit making capacity 145 kA (Icm) at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2, 145 kA (Icm) at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2, 145 kA (Icm) at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 145 kA (Icm) at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Long time pick-up adjustment range 0.4...1 x In adjustable in step of 1 A
Type of measurement power meter
Mounting support rails, base plate
Measurement voltage 145.6-828 V AC 50/60 Hz per phase
Environment
Relative humidity 0-95 % conforming to IEC 60068-2-30
Ambient air temperature for storage -40-85 °C
Operating altitude <= 5000 m 94 % of In, <= 4000 m 96 % of In, <= 3000 m 99 % of In, <= 2000 m without derating
Product certifications IECEE CB Scheme
Measurement category category IV conforming to IEC 61010-2-30
Pollution degree 3 conforming to EN/IEC 60947-1
IP degree of protection IP30 conforming to EN/IEC 60529
Ambient air temperature for operation -35--35 °C (for start-up of product), -25-70 °C (operating)
Electromagnetic compatibility conducted and radiated emissions conforming to CISPR 22, conducted RF disturbances A conforming to EN/IEC 61000-4-6, 1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5, electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4, susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3, electrostatic discharge immunity test conforming to EN/IEC 61000-4-2
IK degree of protection IK07 conforming to EN/IEC 62262
Overvoltage category IV conforming to EN/IEC 61010-1
Environmental characteristic wet location not approved for use conforming to EN/IEC 61010-1
Standards EN/IEC 61010-1, EN/IEC 60947-2, EN/IEC 60947-1
Packing Units
Unit Type of Package 1 1
Number of Units in Package 1 1
Package 1 Height 62.000 cm
Package 1 Width 60.000 cm
Package 1 Length 80.000 cm
Package 1 Weight 92.999 kg