LR9D01

$147.92
Special Order-Generally ships in 14 to 21 Business Days
SKU
LR9D01

TeSys LRD - electronic thermal overload relay - 3P - 0.1...0.5 A

Main
Range
TeSys
Product name
TeSys LRD
Device short name
LR9D
Product or component type
Electronic thermal overload relay
Relay application
Motor protection
Product compatibility
LC1D09

LC1D12

LC1D18

LC1D25

LC1D32

LC1D38
Thermal overload class
Class 5…30
Thermal protection adjustment range
0.1...0.5 A
Power consumption in W
<= 300 mW
Mounting support
Plate with specific accessories

Rail with specific accessories

Under contactor
Complementary
[Ue] rated operational voltage
690 V for power circuit

660 V for signalling circuit
[Ui] rated insulation voltage
1000 V power circuit

690 V signalling circuit
Tripping threshold
1.25 In conforming to IEC 60947-4-1
Control type
Red push-button stop and manual reset

White 2 microswitches adjustable trip class

Red knob for automatic reset mode

White dial for full-load current adjustment mode
Time range
1.5...4 min - automatic reset time
[Ith] conventional free air thermal current
5 A for signalling circuit
[Uimp] rated impulse withstand voltage
6 kV
Phase failure sensitivity
Phase difference > 40% 3 s conforming to IEC 60947-4-1
Electromagnetic compatibility
Surge withstand 2 kV common mode IEC 61000-4-5

Resistance to electrostatic discharge 8 kV IEC 61000-4-2

Immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3

Immunity to fast transients 2 kV IEC 61000-4-4
Connections - terminals
Power circuit : screw clamp terminals 1 cable 16 mm² - cable stiffness: solid or flexible - without cable end

Control circuit : screw clamp terminals 1 cable 2.5 mm² - cable stiffness: solid or flexible - without cable end
Tightening torque
Control circuit : 0.8 N.m - on screw clamp terminals

Power circuit : 3.1 N.m - on screw clamp terminals
Height
72.5 mm
Width
45 mm
Depth
79.9 mm
Product weight
0.18 kg
Environment
Standards
IEC 60947-4-1

CSA C22.2

GB 14048.4

UL 60947-4-1
Product certifications
CCC

CSA

TÜV

UL
IP degree of protection
IP20 front face conforming to IEC 60529

IP20 front face conforming to VDE 0106
Ambient air temperature for operation
-25...70 °C conforming to IEC 60255-8
Ambient air temperature for storage
-55...80 °C
Operating altitude
2000 m without derating
Mechanical robustness
Vibrations 10...150 Hz 6 Gn IEC 60068-2-6 IEC 60068-2-6

Shocks 11 ms 15 gn IEC 60068-2-7 IEC 60068-2-7
Dielectric strength
6 kV at 50 Hz conforming to IEC 60255-5
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Write Your Own Review
You're reviewing:LR9D01

   Frequently Asked Questions and Answers


  • r030_Nuisance tripping on TeSys GV and LRD

    Goals and Symptoms Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Facts and Changes Nuisance tripping, LRD, GV2, GV3, GV7 Causes and Fixes Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Attachments (Removed File URL: 191721_5CB2/R030_How_to_trouble_Shoot_a_Nuisance_tripping_on_GV_and_LRD.pdf)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/92d280a779478116c125757d00422c40/fl_bl...
    Read more

  • Can the TeSys range overload relays be used in DC application?

    The overload relay with the bimetal technology (Thermal Overload) only can be used in DC application.  Tesys LRD Range Tesys LRD thermal overload relays can be used in a DC application. Series up the connections through the contactor and overload. Tesys LR9 Range Do not use the Tesys LR9 Electronic overload relay because under phase failure condition there will be nuisance tripping.
    Read more

  • What is the replacement for LR2D3357?

    The replacement for LR2D3357 is a - LRD3357 LRD350  TeSys LRD thermal overload relays - 37...50 A - class 10A For further information see:https://www.schneider-electric.com.au/en/product-range-selector/1885-tesys-lrd/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D1885%26prd_id%3DLRD3357%26scp_id%3DAU_en
    Read more

  • What is the part number for overload 37-50a for lc1d50u7?

    The part number for overload 37-50A for LC1D50U7 is LRD3357 LRD3357 TeSys LRD thermal overload relays - 37...50 A - class 10A For more information see: https://eshop.schneider-electric.com/product.aspx?prod_id=LRD3357&org=21&lang=1&dist=276&tab=10&ses_id
    Read more

  • What is the overload with 55-70a range for lc1d80 contactor?

    The overload with 55-70A range for LC1D80 contactor is LRD3361. LRD3361 TeSys LRD thermal overload relays - 55...70 A - class 10A For further information see: https://www.schneider-electric.us/en/product-range-selector/1885-tesys-lrd/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3DUS%26el_typ%3Dproduct%26range_id%3D1885%26prd_id%3DLRD3361%26scp_id%3DUS_en
    Read more

Instruction sheet
  • file image TeSys LR9D, electronic thermal overload relays (pdf) download image`
CAD
  • file image Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps (pdf) download image`
  • file image Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps (stp) download image`
  • file image Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps with accessorie LAD7B205 (pdf) download image`
  • file image Electronic thermal overload protection TeSys LR9D 0.1... 32 Amps with accessorie LAD7B205 (stp) download image`
Certificate
  • file image CCC Certificate TeSys LRD - LR9D01-32 (pdf) download image`
  • file image Certificate TeSys LRD - LR9D01-32 (pdf) download image`
Declaration of conformity
  • file image EU Declaration TeSys LR9 - LR9D-LR9D110s-LAD7B205 (pdf) download image`
End of life manual
  • file image TeSys LR9D - EoLi (pdf) download image`
Product environmental
  • file image TeSys LR9D Solid State Overload Relay - PEP (pdf) download image`
REACh Declaration
  • file image TeSys LRD - electronic thermal overload relay - 3P - 0.1...0.5 A (pdf) download image`
RoHs Declaration
  • file image TeSys LRD - electronic thermal overload relay - 3P - 0.1...0.5 A (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech