SKU:

GV2RT05

TeSys Deca, Motor circuit breaker,TeSys Deca,3P,0.63-1A,thermal magnetic,screw clamp terminals,toggle handle

Old price: $391.60 INC GST
$246.71 INC GST
Available for Shipping : 12-Jan-2026
TeSys Deca, Motor circuit breaker,TeSys Deca,3P,0.63-1A,thermal magnetic,screw clamp terminals,toggle handle
  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents
  • Maintenance guide via EcoStruxureTM Facility Expect
Manufacturer: Schneider Electric
Delivery date: 12-Jan-2026
TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for high starting current peak motor applications 0.25-0.37kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.63-1A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Products specifications

Attribute name Attribute value
Main
Device short name GV2RT
Device application transformer, motor protection
Range TeSys Deca
Range of product TeSys GV2
Trip unit technology thermal-magnetic
Product name TeSys Deca, TeSys GV2
Product or component type motor circuit breaker
Complementary
Compatibility code GV2RT
Mechanical durability 100000 cycles
Tightening torque 1.7 N.m - on screw clamp terminal
Suitability for isolation yes conforming to IEC 60947-1 § 7-1-6
Breaking capacity 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
Electrical durability 100000 cycles for AC-3e at 415 V In, 100000 cycles for AC-3 at 415 V In
Power dissipation per pole 2.5 W
Control type toggle
Fixing mode panel: screwed (with adaptor plate), 35 mm symmetrical DIN rail: clipped
Maximum operating rate 25 cyc/h
Magnetic tripping current 22-22 A
Height 89 mm
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Depth 78.5 mm
Width 45 mm
Poles description 3P
Direct connector without
Thermal protection adjustment range 0.63-1 A conforming to IEC 60947-4-1
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Utilisation category AC-3e conforming to IEC 60947-4-1, AC-3 conforming to IEC 60947-4-1, category A conforming to IEC 60947-2
Motor power kW 1-1 kW at 690 V AC 50/60 Hz transformer protection, 0.63-0.63 kW at 500 V AC 50/60 Hz transformer protection, 0.63-0.63 kW at 440 V AC 50/60 Hz transformer protection, 0.55-0.55 kW at 690 V AC 50/60 Hz motor protection high peak current, 0.37-0.37 kW at 500 V AC 50/60 Hz motor protection high peak current, 0.37-0.37 kW at 440 V AC 50/60 Hz motor protection high peak current, 0.25-0.25 kW at 440 V AC 50/60 Hz motor protection high peak current, 0.37-0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current, 0.25-0.25 kW at 400/415 V AC 50/60 Hz motor protection high peak current, 0.12-0.12 kW at 220/230 V AC 50/60 Hz motor protection high peak current, 0.09-0.09 kW at 220/230 V AC 50/60 Hz motor protection high peak current
[Ith] conventional free air thermal current 1 A conforming to IEC 60947-4-1
Network type AC
Rated duty continuous conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[In] rated current 1 A
Environment
Fire resistance 960 °C conforming to IEC 60695-2-11
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for storage -40-80 °C
Climatic withstand conforming to IACS E10
Ambient air temperature for operation -20-60 °C
Mechanical robustness vibrations: 5 Gn, 5...150 Hz, shocks: 30 Gn for 11 ms
IK degree of protection IK04
Operating altitude 2000 m
Standards EN/IEC 60947-4-1, EN/IEC 60947-2
Product certifications UKCA, BV, LROS (Lloyds register of shipping), EAC, CSA, UL, CCC
Packing Units
Unit Type of Package 1 1
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 9.300 cm
Package 1 Length 8.700 cm
Package 1 Weight 229.000 g
Unit Type of Package 2 2
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.799 kg
Unit Type of Package 3 3
Number of Units in Package 3 384
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 102.564 kg