SKU:

ATV930C13N4F

variable speed drive, Altivar Process ATV900, floor standing ATV930, 132kW, 400 to 440V, without braking unit, IP21

Old price: $33,328.90 INC GST
$25,496.61 INC GST
Available for Shipping : 12-Mar-2026
variable speed drive, Altivar Process ATV900, floor standing ATV930, 132kW, 400 to 440V, without braking unit, IP21
Manufacturer: Schneider Electric
Delivery date: 12-Mar-2026
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 132kW for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 110kW for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 440Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.

Products specifications

Attribute name Attribute value
Main
Synchronous motor control profile synchronous reluctance motor, permanent magnet motor
Device application industrial application
EMC filter with EMC plate option, integrated
Nominal switching frequency 2.5 kHz
Continuous output current 211 A at 2.5 kHz for heavy duty, 250 A at 2.5 kHz for normal duty
Discrete input logic 16 preset speeds
Mounting mode floor-standing
[Us] rated supply voltage 380...440 V - 15...10 %, 380...440 V
Motor power kW 110.0 kW for heavy duty, 132.0 kW for normal duty
Range of product Altivar Process ATV900
Maximum output frequency 599 Hz
Option card communication module for Ethernet Powerlink, slot B: resolver encoder interface module, slot B: analog encoder interface module, slot B: 5/12 V digital encoder interface module, slot A/slot B/slot C: output relay extension module, slot A/slot B/slot C: digital and analog I/O extension module, slot A: communication module for CANopen screw terminals, slot A: communication module for CANopen SUB-D 9, slot A: communication module for CANopen daisy chain RJ45, slot A: communication module for EtherCAT, slot A: communication module for DeviceNet, slot A: communication module for PROFINET, slot A: communication module for Profibus DP V1
Number of output phases 3
Number of input phases 3
Design of frequency changer U converter
Product specific application process for industrial
Nominal output current 250.0 A
Communication port protocol EtherNet/IP, Modbus TCP, Modbus serial
Maximum transient current 317 A during 60 s (heavy duty), 300 A during 60 s (normal duty)
Switching frequency 2...8 kHz adjustable, 2.5...8 kHz with derating factor
Relative symmetric mains voltage tolerance 10 %
IP degree of protection IP21
Apparent power 136 kVA at 400 V (heavy duty), 161 kVA at 400 V (normal duty)
Product or component type variable speed drive
Variant without braking chopper, standard version
Asynchronous motor control profile variable torque standard, optimized torque mode, constant torque standard
Network number of phases 3 phases
Line current 179.0 A at 440 V (heavy duty), 210.0 A at 440 V (normal duty), 207.0 A at 380 V (heavy duty), 244.0 A at 380 V (normal duty)
Product destination asynchronous motors, synchronous motors
Network frequency 50...60 Hz
Prospective line Isc 50 kA
Complementary
With safety function Safely Limited Speed (SLS) True
Number of HW interfaces other 0
Supply internal supply for digital inputs and STO: 24 V DC (21-27 V), <200 mA, protection type: overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection, external supply for digital inputs: 24 V DC (19-30 V), <1.25 mA, protection type: overload and short-circuit protection
Number of HW interfaces serial TTY 0
Protection type break on the control circuit: drive, overspeed: drive, line supply phase loss: drive, line supply undervoltage: drive, line supply overvoltage: drive, overvoltages on the DC bus: drive, motor phase break: drive, short-circuit protection: drive, overload of output voltage: drive, overcurrent between output phases and earth: drive, overheating: drive, safe torque off: drive, thermal protection: drive, motor phase break: motor, safe torque off: motor, thermal protection: motor
Discrete input type STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm, DI7, DI8 programmable as pulse input: 0-30 kHz, 24 V DC (<= 30 V), DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
Braking to standstill by DC injection
Type of polarization no impedance for Modbus serial, no impedance
Supporting protocol for SUCONET False
Power loss static current independent 73.0 W
Quantity per set 1
Brake chopper integrated False
With safety function Safe programmable logic False
Isolation between power and control terminals
Number of inputs, bidirectional, not potential-free 0
Number of inputs, potential-free 0
Supporting protocol for EtherNet/IP True
Supporting protocol for DeviceNet False
Refresh time relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current relay output R1, R2, R3: 5 mA at 24 V DC
Physical interface 2-wire RS 485, Ethernet
Analogue output number 2
Operating element present True
Supporting protocol for PROFINET IO True
Supporting protocol for Data-Highway False
Connector type 1 RJ45, 2 RJ45
Input compatibility STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2, DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68, DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2
Number of HW interfaces serial RS232 0
Accuracy +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output, +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Number of HW interfaces serial RS485 1
Supporting protocol for PROFINET CBA True
Base load current at low overload 250.0 A
Supporting protocol for PROFIBUS True
Supporting protocol for ASI False
Data format 8 bits, configurable odd, even or no parity, 8 bits, configurable odd, even or no parity for Modbus serial
Number of HW interfaces USB 0
With safety function Safe torque off (STO) True
Relay output number 3
Supporting protocol for SERCOS False
With safety function Safe Speed Monitor (SSM) False
Supporting protocol for SafetyBUS P False
Supporting protocol for AS-Interface Safety at Work False
Transmission frame RTU
Base load current at high overload 211.0 A
Maximum output voltage 440.0 V
Encoder protocol TTL/HTL, SSI 5V, SSI 24V, RS 422, resolver, EnDat 2.2, 1 Vpp
Acceleration and deceleration ramps linear adjustable separately from 0.01...9999 s
Height 2150 mm
With safety function Safe brake management (SBC/SBT) True
Number of HW interfaces serial RS422 0
Supporting protocol for TCP/IP True
Optical interface present False
Electrical connection motor: M12 bar, line side: M12 bar, control: removable screw terminals 0.5...1.5 mm²
Supporting protocol for other bus systems False
Supporting protocol for Foundation Fieldbus False
Sampling duration 5 ms +/- 1 ms (AQ1, AQ2) - analog output, 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms (DI7, DI8) - pulse input, 2 ms +/- 0.5 ms (DI1...DI8) - discrete input
Computer port True
Application in industrial area permitted True
Supporting protocol for PROFIsafe False
Analogue input type AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits, AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
Depth 605 mm
Supporting protocol for KNX False
Transmission rate 19200 bit/s, 9600 bit/s, 4.8 kbps, 10, 100 Mbits, 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial, 10/100 Mbit/s for Ethernet IP/Modbus TCP
Width 400 mm
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
Housing material sheet steel
Supporting protocol for LON False
Supporting protocol for BACnet False
Number of addresses 1-247 for Modbus serial, 1-247
Linearity error AQ1, AQ2: +/- 0.2 % for analog output, AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Number of HW interfaces parallel 0
Power loss per device current dependent 2992.0 W
Discrete input number 10
With safety function Safe Operating Stop (SOS) False
Method of access slave Modbus TCP
With safety function Safely Limited Position (SLP) False
With safety function Safe Position (SP) False
Supporting protocol for DeviceNet Safety False
Discrete output number 2
Supporting protocol for MODBUS True
Motor slip compensation automatic whatever the load, can be suppressed, adjustable, not available in permanent magnet motor law
Analogue input number 3
Application in domestic and commercial area permitted False
Supporting protocol for CAN True
1 phase low current possible False
Relay output type configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles, configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles, configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
With safety function Safe Direction (SDI) False
Net weight 310 kg
EMC limit value (complied) True
Nominal output power 132.0 W
Relative symmetric network frequency tolerance 5 %
Supporting protocol for INTERBUS-Safety False
Local signalling presence of voltage: 1 LED (red), communication module status: 2 LED (dual colour), embedded communication status: 5 LED (dual colour), local diagnostic: 3 LED (mono/dual colour)
Supporting protocol for INTERBUS False
Exchange mode half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
4 quadrant operation possible False
Maximum switching current relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 30 V DC, relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 250 V AC, relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1 on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1 on resistive load, cos phi = 1 : 3 A at 250 V AC
Number of HW interfaces industrial Ethernet 2
Discrete output type logic output DQ- 0-1 kHz <= 30 V DC 100 mA, programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA, logic output DQ+ 0-1 kHz <= 30 V DC 100 mA
Number of HW interfaces PROFINET 0
Analogue output type software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits, software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Power dissipation in W 2520 W, switching frequency 2.5 kHz (heavy duty), 3150 W, switching frequency 2.5 kHz (normal duty)
Discrete input logic positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1), positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1), negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1), positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Environment
Maximum deflection under vibratory load (during storage) 1.5 mm at 2...13 Hz
Ambient air transport temperature -40-70 °C
Maximum acceleration under shock load (during storage) 150 m/s² at 11 ms
Maximum THDI <48 % full load conforming to IEC 61000-3-12
Operating position vertical +/- 10 degree
Assembly style in floor-standing enclosure
Relative humidity 5-95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for storage -40-70 °C
Permitted relative humidity (during transport) class 2K5 according to EN 60721-3
Noise level 69 dB, 69 dB conforming to 86/188/EEC
Maximum acceleration under vibratory load (during storage) 10 m/s² at 13...200 Hz
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Marking CE
Environmental class (during transport) class 2S1 according to EN 60721-3-2, class 2C3 according to EN 60721-3-2
Volume of cooling air 720 m3/h
Ambient air temperature for operation 40-50 °C (with derating factor), -15-40 °C (without derating), 0-50 °C
Electromagnetic compatibility conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree 2
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 150 m/s² at 11 ms
Maximum acceleration under vibratory load (during transport) 10 m/s² at 13...200 Hz
Environmental class (during operation) class 3S3 according to IEC 60721-3-3, class 3C3 according to IEC 60721-3-3
Environmental class (during storage) class 1S2 according to EN 60721-3-1, class 1C3 according to EN 60721-3-1
Overvoltage category III
Operating altitude 1000...4800 m with current derating 1 % per 100 m, <= 1000 m without derating
Permitted relative humidity (during operation) class 3K5 according to EN 60721-3
Regulation loop adjustable PID regulator
Permitted relative humidity (during storage) class 1K5 according to EN 60721-3
Vibration resistance 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
Environmental characteristic dust pollution resistance class 3S3 conforming to IEC 60721-3-3, chemical pollution resistance class 3C3 conforming to IEC 60721-3-3
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Maximum deflection under vibratory load (during transport) 1.5 mm at 2...13 Hz
Standards IEC 61800-5-1, IEC 61800-3, IEC 61800-2, IEC 60204-1
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Product certifications C-Tick, EAC, ATEX
Maximum input current 244.0 A
Packing Units
Unit Type of Package 1 1
Number of Units in Package 1 1
Package 1 Height 238.5 cm
Package 1 Width 120.0 cm
Package 1 Length 110.0 cm