A9MEM2150

$593.86
Generally ships in 1 to 2 days
SKU
A9MEM2150

modular single phase power meter iEM2150 - 230V - 63A with comm Modbus

Main
Range
Acti 9
Product name
Acti 9 iEM2100
Device short name
IEM2150
Product or component type
Energy meter
Complementary
Poles description
1P + N
Type of measurement
Active and reactive power

Active and reactive energy

Voltage

Current
Metering type
Active, reactive, apparent energy (signed, four quadrant)
Device application
Sub billing

Partial meter
Accuracy class
Active energy : class 1 according to IEC 62053-21

Reactive energy : class 2 according to IEC 62053-23
Analogue input type
Direct input
[In] rated current
63 A
Rated voltage
230 V +/- 20 %
Network frequency
50 Hz

60 Hz
Frequency measurement range
45...65 Hz
Technology type
Electronic
Display type
LCD display
Sampling rate
32 samples/cycle
Measurement current
0...63 A
Display digits
8
Maximum value measured
999999.99 kWh
Information displayed
1 tariff
Communication port protocol
Modbus RTU 3 wires, : 1.2, 2.4, 4.8, 9.6, 19.2 and 38.4 kbauds, even/odd or none, insulation: 4000 V
Communication port support
RS485 (screw terminals)
Local signalling
LED (red) : accuracy checking 1...1000 p/kWh
Number of inputs
0
Number of outputs
0
[Us] rated supply voltage
96...276 V AC 50 Hz
Power consumption in VA
<= 2 VA
Power consumption in W
<= 1 W
[Uimp] rated impulse withstand voltage
6 kV 1.2/50 µs
Mounting mode
Clip-on
Mounting support
DIN rail
Connections - terminals
Power circuit : bottom tunnel type terminals for 1 1.65...33 mm² solid cable(s)

Power circuit : bottom tunnel type terminals for 1 1.65...33 mm² stranded cable(s) with cable end

Communication : top screw clamp terminals for 1 1...4 mm² solid cable(s)

Communication : top screw clamp terminals for 1 1...2.5 mm² stranded cable(s) with cable end
Tightening torque
Power circuit : 2 N.m with PZ2

Communication : 0.5 N.m (3.5 mm blade)
Wire stripping length
Power circuit : 17 mm

Communication : 7 mm
Standards
IEC 62053-21

IEC 62053-23

IEC 62052-11

IEC 62052-31
Product certifications
CE
Environment
IP degree of protection
IP20 conforming to IEC 60529
Overvoltage category
III
Pollution degree
2
Flame retardance
V0 conforming to UL 94
Ambient air temperature for operation
-25...55 °C
Ambient air temperature for storage
-25...70 °C
Relative humidity
95 %
Colour
White
9 mm pitches
4
Width
36 mm
Height
90 mm
Depth
64 mm
Product weight
0.175 kg
Offer Sustainability
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Write Your Own Review
You're reviewing:A9MEM2150

   Frequently Asked Questions and Answers


  • Do we have single pole Watt hour meter in 63 amp and resettable?

    Part number A9MEM2105 has a resettable counter in the front . Please refer the below linkhttps://www.schneider-electric.com.au/en/product-range-selector/61083-acti-9-iem2000-series/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D61083%26prd_id%3DA9MEM2105%26scp_id%3DAU_en
    Read more

  • Is there a D-Curve RCBO available?

    No, unfortunately we do not have this part in our range. However, we can offer a D-Curve breaker in the Acti 9 Series (A9F55***) as well as a add-on Vigi block RCD.  *** = Number of poles followed by the amp rating E.g. 4 pole 32Amp would be A9F55432. See Below for List of  Blocks:
    Read more

  • What is the physical difference between the c120h and the ic120h?

    There are no physical differences. They are same dimensions will fit in the same spot. It is just the part name change to match the Acti 9 series.
    Read more

  • What is the replacement for ME3ZR, 17076 Meter?

    The replacement for ME3ZR, 17076 Meter is A9MEM3110 A9MEM3110 For more information see : https://www.schneider-electric.com.au/en/product-range-selector/61273-acti-9-iem3000-series/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D61273%26prd_id%3DA9MEM3110%26scp_id%3DAU_en
    Read more

  • Which KWH meter will measure Solar inputs with Modbus connections?

    Can go with part number A9MEM3255 , unless it is DC input. Please refer the below link for more information, https://www.schneider-electric.com.au/en/product-range-selector/61273-acti-9-iem3000-series/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D61273%26prd_id%3DA9MEM3255%26scp_id%3DAU_en
    Read more

User guide
  • file image iEM2100 series user manual (pdf) download image`
Catalogue
  • file image PowerLogic Selection Guide - Print Version (pdf) download image`
  • file image PowerLogic Selection Guide - Web Version (pdf) download image`
  • file image PowerLogic Catalogue - 266 pages - Print File (NO PRINTED VERSION AVAILABLE) (pdf) download image`
  • file image PowerLogic Catalog - 266 pages Web (NO PRINTED VERSION AVAILABLE) (pdf) download image`
Instruction sheet
  • file image iEM2100 series installation sheet (pdf) download image`
Technical leaflet
  • file image iEM2000 & iEM2100 Series Technical Datasheet - Print Version (pdf) download image`
  • file image iEM2000 & iEM2100 Series Technical Datasheet - Web Version (pdf) download image`
Declaration of conformity
  • file image ECDiEM21xx -V1a (pdf) download image`
REACh Declaration
  • file image modular single phase power meter iEM2150 - 230V - 63A with comm Modbus (pdf) download image`
RoHs Declaration
  • file image modular single phase power meter iEM2150 - 230V - 63A with comm Modbus (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech