XRBA42100

$995.42
Special Order-Generally ships in 14 to 21 Business Days
SKU
XRBA42100

standard duty screw limit switch - bare drive shaft - 4 C/O - 17:1 - right-hand

Main
Range of product
XR and XF
Product or component type
Standard duty screw limit switch
Device short name
XRBA
Product specific application
Liquid level control in pumping systems

Position control of moving parts of hoisting or materials handling equipment
Material
Aluminium alloy (body housing)

Aluminium alloy (cover)

Stainless steel (input drive shaft)
Type of operator
Bare drive shaft
Operating position
Right-hand side
Maximum revolution speed
1000 rpm of input drive shaft
Number of poles
1
Contact operation
Snap action
[Ie] rated operational current
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
Product compatibility
XRBZ900
Complementary
Reduction ratio
17:1
Operating torque
5 N.m at 20 °C
Mechanical durability
15000000 cycles
Contacts type and composition
4 C/O
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
250 V conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Resistance across terminals
<= 25 MOhm
Short-circuit protection
10 A cartridge fuse type gG
Connections - terminals
Captive screw clamp terminals, connection capacity: 2 x 1.5 mm² with cable end
Electrical durability
500000 cycles AC-15 50/60 Hz inductive at 12 V, 65 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz inductive at 127 V, 450 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz inductive at 220 V, 530 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz inductive at 24 V, 108 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz inductive at 48 V, 216 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz resistive at 12 V, 18 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz resistive at 127 V, 165 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz resistive at 220 V, 220 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz resistive at 24 V, 35 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles AC-15 50/60 Hz resistive at 48 V, 700 VA, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 inductive at 110 V, 130 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 inductive at 12 V, 55 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 inductive at 220 V, 135 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 inductive at 24 V, 84 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 inductive at 48 V, 110 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 resistive at 110 V, 65 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 resistive at 12 V, 27 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 resistive at 220 V, 67 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 resistive at 24 V, 39 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1

500000 cycles DC-13 resistive at 48 V, 50 W, operating rate 3600 cyc/h, load factor 0.5 EN/IEC 60947-5-1
Adaptation for potentiometer
With, ratio 1
Cable entry
1 entry tapped for Pg 16 cable gland, clamping capacity: 10...14 mm

1 entry tapped for Pg 9 cable gland, clamping capacity: 5...8 mm
Product weight
1.5 kg
Environment
Standards
EN/IEC 60947-5-1
Protective treatment
TC
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Shock resistance
80 gn for 11 ms
Vibration resistance
> 5 gn (10...60 Hz)
IP degree of protection
IP55 conforming to EN/IEC 60529

IP557 conforming to NF C 20-010
Offer Sustainability
RoHS (date code: YYWW)
Will be compliant  on  4Q2014
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XRBA42100

   Frequently Asked Questions and Answers


  • Osisense XC special_XCRT115 XCRT215 Mechanical stop of the roller arm_How to adjust

    Please find attached a document showing the mechanical stop of the roller arm and how to adjust. Such function is not documented into the catalogue pages. XCRT115 XCRT215_Mechanical stop of the roller arm.pdf
    Read more

  • Osisense XC special - Up-to-date CCC certificate for the XCR limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCR limit switches produced in France, valid up to January 2020. CCC 2008010305268106_France_XCR valid up to january 2020.pdf
    Read more

  • What is the ZC4CC reference? How to order?

    ZC4CC is not a commercial reference, but the marking on the contact ZC4CC2, sold in spare parts for the obsolete XR2PA* safety screw limit switch for mechanical press. See attached picture. ZC4CC2 is still available to order in 2015. It is a slow break contact type. ZC4CC picture.jpg
    Read more

  • Osisense XC_Obsolete XCKP9279 switch with reset : how to replace it

    The obsolete XCKP9279 switch was a roller lever plunger switch with 2 NC contacts, snap action block, for vertical direction (special model), having reset function, plastic casing in black colour. The equivalent switch in the Osisense XC offer is the XCPR2927G13 commercial reference with 2NC contacts positive opening, snap action. Attached corresponding datasheet downloaded from \'tesensors.com\' site. OsiSense XC_XCPR2927G13 datasheet.pdf
    Read more

  • Osisense XC - Datasheet of the adapted limit switch xcmn2115t1l0

    Please find attached the datasheet of the adapted limit switch XCMN2115T1L0, using a special cable halogen free for railway equipments, complying to EN 50306 and EN 45545 standards. Cable lenght = 1m. This reference is available to order without any restriction. It is not in stock, it is produced at order reception by the assembly plant. A second similar reference exists with 50cm cable lenght only : XCMN2115T05L0. Adapted switch XCMN2115T1L0 datasheet.pdf
    Read more

Declaration of conformity
  • file image XR2A/B/PA... and XRB... screw limit switches, XR2C... cyclic programmers - EU declaration of conformity (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech