XPSVNE3742HSP
module XPSVN - zero speed detection - 230 V DC for motor power supply > 60 Hz
SKU
XPSVNE3742HSP
$1,430.29
Catalogue
Certificate
Declaration of conformity
End of life manual
Product environmental
module XPSVN - zero speed detection - 230 V DC for motor power supply > 60 Hz
auxiliary supply | 230 V |
---|---|
product destination | For motor power supply > 60 Hz |
[Us] rated supply voltage | 230 V |
Write Your Own Review
Main
- Range of product
- Preventa Safety automation
- Product or component type
- Preventa safety module
- Safety module name
- XPSVNE
- Safety module application
- For zero speed detection
- Function of module
- Monitoring 3-phase motor with variable number of poles and star-delta starting
Monitoring 3-phase motor + variable speed drive
Monitoring 3-phase motor with star-delta starting
Monitoring 3-phase motor
Monitoring dc motor
Monitoring XPS AK
Monitoring star-delta motor starter and guard switch type XCS E - Safety level
- Can reach PL d/category 3 conforming to EN/ISO 13849-1
Can reach SILCL 2 conforming to EN/IEC 62061 - Safety reliability data
- MTTFd = 124.1 years conforming to EN/ISO 13849-1
DC > 99 % conforming to EN/ISO 13849-1
PFHd = 9.26E-9 1/h conforming to EN/IEC 62061 - [Us] rated supply voltage
- 230 V AC (- 15...10 %)
- Output type
- Relay 1 NO + 1 NC, volt-free
- Number of additional circuits
- 2 solid state outputs
Complementary
- Product destination
- For motor power supply > 60 Hz
- Power consumption in VA
- <= 7 VA
- Input voltage
- 500 Vrms
- Input detection threshold
- 0.01...0.1 V
- Breaking capacity
- C300 : holding 180 VA AC-15 for relay output
C300 : inrush 1800 VA AC-15 for relay output - Breaking capacity
- 10 mA / 48 V for solid state output circuit
20 mA / 24 V for solid state output circuit
1.5 A / 24 V - L/R = 50 ms, DC-13 for NO relay output circuit
1.2 A / 24 V - L/R = 50 ms, DC-13 for NC relay output circuit - [Ith] conventional free air thermal current
- <= 2.5 A for relay output
- Associated fuse rating
- 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
- Minimum output current
- 10 mA for relay output
- Minimum output voltage
- 17 V for relay output
- [Ui] rated insulation voltage
- 300 V, degree of pollution 2 conforming to IEC 60947-5-1
300 V, degree of pollution 2 conforming to DIN VDE 0110 parts 1 and 2 - [Uimp] rated impulse withstand voltage
- 4 kV overvoltage category III, conforming to IEC 60947-5-1
4 kV overvoltage category III, conforming to DIN VDE 0110 parts 1 and 2 - Local signalling
- 4 LEDs
- Connections - terminals
- Captive screw clamp terminals, removable terminal block flexible cable : 0.2...1.5 mm² without cable end, 2 wires
Captive screw clamp terminals, removable terminal block flexible cable : 0.2...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals, removable terminal block flexible cable : 0.25...1 mm² with cable end, without bezel, 2 wires
Captive screw clamp terminals, removable terminal block flexible cable : 0.25...2.5 mm² with cable end, with bezel, 1 wire
Captive screw clamp terminals, removable terminal block flexible cable : 0.25...2.5 mm² with cable end, without bezel, 1 wire
Captive screw clamp terminals, removable terminal block flexible cable : 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Captive screw clamp terminals, removable terminal block solid cable : 0.2...1 mm² without cable end, 2 wires
Captive screw clamp terminals, removable terminal block solid cable : 0.2...2.5 mm² without cable end, 1 wire - Mounting support
- 35 mm symmetrical DIN rail
- Depth
- 114 mm
- Height
- 99 mm
- Width
- 45 mm
- Product weight
- 0.6 kg
Environment
- Standards
- EN/IEC 60204-1
EN/IEC 60947-5-1 - Product certifications
- CSA
TÜV
UL - IP degree of protection
- IP20(terminals) conforming to EN/IEC 60529
IP40(enclosure) conforming to EN/IEC 60529 - Ambient air temperature for operation
- -10...55 °C
- Ambient air temperature for storage
- -25...85 °C
Contractual warranty
- Warranty period
- 18 months