TBUP50-1200

$2,388.14
Special Order-Generally ships in 14 to 21 Business Days
SKU
TBUP50-1200

SP50 with Internal 3G Modem and External Antenna

Main
Range of product
SCADAPack 50
Product or component type
Wireless remote data logger
Function of module
Data logger

3G GSM modem with external antenna
Complementary
Battery type
Li-SOCl2 (Lithium-Thionyl Chloride) 2
Current consumption
<= 30 µA sleep mode

<= 30 mA measurement mode

<= 400 mA with GSM communication
Discrete input number
4 dry contact
Analogue input number
4
Analogue input type
Voltage 0...100 mV

Voltage 0...1 V

Resistor 0...2000 Ohm

Pt 100

Pt 1000

Current 0...20 mA

Current 4...20 mA

Voltage +/- 10 V
Communication service
SMS notifications
Integrated connection type
Modbus RS485
Transmission rate
38400 bit/s
Measurement resolution
16 bits
Standards
RoHS compliant

UL 61010-1
Marking
CE
Environment
Vibration resistance
1 gn 3.5 mm 5...150 Hz IEC 60068-2-6
Shock resistance
15 gn 11 ms 3 shocks/3 axis IEC 60068-2-27
IP degree of protection
IP68
Ambient air temperature for operation
-25...60 °C
Relative humidity
0...90 %
Operating altitude
0...2000 m
Offer Sustainability
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Write Your Own Review
You're reviewing:TBUP50-1200

   Frequently Asked Questions and Answers


  • Is There a Recommendation For Higher Capacity Shunts That Can Be Used With The Conext Battery Monitor?

    Issue Does Schneider have any recommendations for higher capacity shunts with the battery monitor? Environment Battery Monitor with a large DC system Product Family Conext Battery Monitor Cause  Current shunt is rated too low, and/or seems to be getting too hot while inverting or charging.   Resolution Below is a table from the Battery Monitor Owner's Guide recommending Deltec shunts for various capacities.   The shunt that comes with the Battery Monitor is rated for 350A continuou...
    Read more

  • What is the complete part number for the Branch Circuit Power Monitor (BCPM)?

    There are three monitoring options offered with the BCPM: BCPMA -- Advanced: power and energy per circuit and mains BCPMB -- Intermediate: current per circuit, power and energy per mains BCPMC -- Basic: current only per circuit and mains A complete part number includes the BCMP model, the CT spacing, the number of CTs, and the branding identifier. BCPM (A, B, or C) (0 or 1) (42 or 84) (S or D) A = Advanced B = Intermediate C = Basic 0 (zero) = 3/4\' spacing between CTs on strips 1 (one) = 1\' spacing...
    Read more

  • EcoBreeze Variable Speed Drive Technical Spec’s

                                                                                         &nbs...
    Read more

  • How do I add Hyesteresis Logic in ClearSCADA?

    If logic is being used to turn an output on/off based on the value of a process value compared to a setpoint there is the possibility that the process value may \'flutter\' just above and below the setpoint value.  This behaviour would cause the output to continuously cycle on and off which could potentially cause damage to the output and exhibit unwanted behaviour. Hysteresis logic can be used to provide an \'ON\' setpoint as well as an \'OFF\' setpoint.  The output would only turn on once the...
    Read more

  • Performing Online Changes on Scadapack Workbench CAM5

    How to edit online using CAM5. 1. Stop Debugging or (Shift+5). 2. Edit changes on workbench program. (see attached file of what can be edited). 3. Then In solution explorer Build solution or (CTRL+SHIFT+B) or use the build solution icon. 4. The online changes Icon should turn from grayed out to active. Click the online changes and then start debugging. Performing Online Changes CAM5.pdf
    Read more

Dimensions Drawings

Dimensions





© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech