SR3XT43BD

$325.97
Special Order-Generally ships in 14 to 21 Business Days
SKU
SR3XT43BD

analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic

Main
Range of product
Zelio Logic
Product or component type
Analogue I/O extension module
Complementary
Analogue input number
2
Analogue input type
Common mode
Analogue input range
0...10 V

0...20 mA

-25...125 °C
Temperature probe type
Pt 100, 3-wire conforming to IEC 751
Maximum permissible voltage
30 V for analogue input circuit
[Imp] maximum permanent current
30 mA for analogue input circuit
Analogue input resolution
10 bits on the input range
Input impedance
18 kOhm, input range: 0...10 V for analogue input circuit

247 Ohm, input range: 0...20 mA for analogue input circuit
Analogue output number
2
Analogue output range
0...10 V
Analogue output resolution
10 bits on the output range
Load type
Resistive load for analogue output
Maximum load current
10 mA for analogue output
Short-circuit protection
With analogue output
LSB value
0.15 °C, - 25...125 °C for analogue input circuit

20 µA, 0...20 mA for analogue input circuit

9.8 mV, 0...10 V for analogue input circuit

9.8 mV, 0...10 V for analogue output
Conversion time
Smart relay cycle time for analogue input circuit

Smart relay cycle time for analogue output
Conversion error
+/- 1 % of the full scale value, input range: 0...10 V (25 °C) for analogue output

+/- 1 % of the full scale value, input range: 0...10 V (55 °C) for analogue output

+/- 1 %, input range: 0...10 V (25 °C) for analogue input circuit

+/- 1 %, input range: 0...10 V (55 °C) for analogue input circuit

+/- 1 %, input range: 0...20 mA (25 °C) for analogue input circuit

+/- 1 %, input range: 0...20 mA (55 °C) for analogue input circuit

+/- 1.5 °C, input range: - 25...125 °C (25 °C) for analogue input circuit

+/- 1.5 °C, input range: - 25...125 °C (55 °C) for analogue input circuit
Repeat accuracy
< +/- 0.3 °C, input range: - 25...125 °C at 25 °C for analogue input circuit

<= +/- 1 %, input range: 0...10 V at 25 °C for analogue input circuit

<= +/- 1 %, input range: 0...10 V at 55 °C for analogue output

<= +/- 1 %, input range: 0...20 mA at 25 °C for analogue input circuit
Operating distance
10 m with screened cable for analogue input circuit

10 m with screened cable for analogue output
Reverse polarity protection
With analogue input circuit
Connections - terminals
Screw terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, semi-solid cable

Screw terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, solid cable

Screw terminals, 2 x 0.25...2 x 1.5 mm², AWG 23...AWG 16, solid cable

Screw terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, flexible cable with cable end

Screw terminals, 2 x 0.25...2 x 0.75 mm², AWG 24...AWG 18, flexible cable with cable end
Tightening torque
0.5 N.m
Product weight
0.11 kg
Environment
Product certifications
CSA

C-Tick

GOST

UL
Standards
EN/IEC 60068-2-27 Ea

EN/IEC 60068-2-6 Fc

EN/IEC 61000-4-11

EN/IEC 61000-4-12

EN/IEC 61000-4-2 level 3

EN/IEC 61000-4-3

EN/IEC 61000-4-4 level 3

EN/IEC 61000-4-5

EN/IEC 61000-4-6 level 3
IP degree of protection
IP20 (terminal block) conforming to IEC 60529

IP40 (front panel) conforming to IEC 60529
Environmental characteristic
EMC directive conforming to EN/IEC 61000-6-2

EMC directive conforming to EN/IEC 61000-6-3

EMC directive conforming to EN/IEC 61000-6-4

EMC directive conforming to EN/IEC 61131-2 zone B

Low voltage directive conforming to EN/IEC 61131-2
Disturbance radiated/conducted
Class B conforming to EN 55022-11 group 1
Pollution degree
2 conforming to EN/IEC 61131-2
Ambient air temperature for operation
-20...55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2

-20...40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient air temperature for storage
-40...70 °C
Operating altitude
2000 m
Altitude transport
<= 3048 m
Relative humidity
95 % without condensation or dripping water
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:SR3XT43BD

   Frequently Asked Questions and Answers


  • Do Zelio Logic relays include software?

    Issue: Do Zelio Logic relays include software? Product Line: Logic relays Environment: Zelio Logic Cause: Product Features Resolution: Zelio soft Software is sold as a separate accessory: SR2SFT01. This can also be downloaded at no charge at  https://www.schneider-electric.com/download/ww/en/results/3541958-SoftwareFirmware/0/8336552-Zelio-Logic/0/?showAsIframe=false CTA-ID : 2025929
    Read more

  • Why does the Zelio Logic Relays turn automatically off.

    One of the main reasons for the Zelio Logic Relays turning off automatically is input supply voltage fluctuation. The voltage limit for Zelio Logic Relays like SR2 B121JD, SR2 B201JD and SR3 B261JD, with standard input voltage 12V DC, is  10.4 VDC to 14.4 VDC. The Zelio Logic Relays work properly within the band 10.4 VDC to 14.4 VDC. The moment the input voltage either falls below the lower limit (10.4 VDC) or goes above upper limi...
    Read more

  • What is the life span of the internal lithium battery of Zelio Logic Relays

    The life span of the internal lithium battery of Zelio Logic Relays is 10 years for temperature between -20 to 50 Degree Celsius and is counted from the date of manufacturing. 
    Read more

  • How to establish bluetooth communication for SR2/SR3 range of Zelio Logic Smart Relay.

    Bluetooth interface SR2BTC01 and Bluetooth Modbus Adapter VW3A8115 can be used for establishing wireless bluetooth communication between SR2/SR3 Zelio Logic Smart Relay and computer.Note:1. The maximum distance between the computer and the module with bluetooth interface is approximately 10 meters.2. The bluetooth interface SR2CBT01 is compatible with ZelioSoft2 V4.1 and higher.3. Also It is necessary to have a SR2/SR3 Zelio Logic Smart Relay with a firmware version V4.0 and higher.The User Manu...
    Read more

  • Will the sr1cbl02 programming cable from the older Zelio-Logic SRI relay work with the newer SR2?

    Issue: Will the SR1CBL02 programming cable from the older Zelio-Logic  SRI relay  work with the  newer SR2? Product Line: Zelio Relays and Timers Environment: All Products Cause: Product Features Resolution: No, cables are not interchangeable CTA-ID : 2025399
    Read more

User guide
  • file image Zelio Logic 2 Quick Start (pdf) download image`
Catalogue
  • file image Smart Relays - Zelio Logic (pdf) download image`
Instruction sheet
  • file image SR3XT43D I/O Zelio2 Analog I/O extension module (pdf) download image`
Certificate
  • file image RCM_SR2_SR3_Zelio_Relay (pdf) download image`
Declaration of conformity
  • file image EC_Declaration_SR2_SR3 (pdf) download image`
End of life manual
  • file image Zelio Logic SR2 - SR3 Smart Relays, Product End-of-Life Instructions (pdf) download image`
  • file image SR3 NET01BD, SR3 XT..., SR3 MBU01BD Network communication and I/O extension modules, Product End-of-Life Instructions (pdf) download image`
Marine certificate
  • file image DNV-GL Marine Certificate Zelio SR2 SR3 Smart Relays (pdf) download image`
Product environmental
  • file image Zelio Logic SR2 - SR3 Smart Relays, Product Environmental Profile (pdf) download image`

Dimensions Drawings

Analog I/O Extension Modules
Mounting on 35 mm/1.38 in. DIN Rail



Screw Fixing (Retractable Lugs)





Connections and Schema

Connection of Smart Relays on DC Supply, with Analog I/O Extension Module
Connection Alternatives

0 - 10 V

0 - 20 mA

Pt100

2

0

0

1

1

0

0

2

0

1

0

1

0

1

1

Application Example with 1 x 0 - 10 V Input and 1 x Pt100 Input



(1)
Screened cables, maximum length 10 m/32.80 ft.
Application Example with 1 x 0 - 20 mA Input and 1 x 0 - 10 V Input



(1)
Screened cables, maximum length 10 m/32.80 ft.


Performance Curves

Compact and Modular Smart Relays
Electrical Durability of Relay Outputs

(in millions of operating cycles, conforming to IEC/EN 60947-5-1)

DC-12 (1)



X:
Current (A)
Y:
Millions of operating cycles
(1)
DC-12: control of resistive loads and of solid state loads isolated by opto-coupler, L/R ≤ 1 ms.

DC-13 (1)



X:
Current (A)
Y:
Millions of operating cycles
(1)
DC-13: switching electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protection diode on the load, DC-12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles).


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech