RPF2AP7

$26.83
Special Order-Generally ships in 14 to 21 Business Days
SKU
RPF2AP7

power relay plug-in - Zelio RPF - 2 NO - 230 V AC - 30 A

Main
Range of product
Zelio Relay
Series name
Power
Product or component type
Plug-in relay
Device short name
RPF
Contacts type and composition
2 NO
[Uc] control circuit voltage
230 V AC
Control type
Without lockable test button
Shape of pin
Flat
Contacts material
Silver tin oxide
[Ithe] conventional enclosed thermal current
25 A at -40...55 °C for relays side by side without a gap

30 A at -40...55 °C for 13 mm gap between two relays
Load current
25 A at 28 V DC

30 A at 250 V AC
Utilisation coefficient
10 %
Complementary
Mounting support
DIN rail

Panel
Control circuit voltage limits
184...253 V
[Ie] rated operational current
30 A at 250 V AC (for NO) conforming to IEC

30 A at 277 V AC (for NO) conforming to UL

20 A at 28 V DC (for NO) conforming to UL

25 A at 28 V DC (for NO) conforming to IEC
[Ui] rated insulation voltage
250 V conforming to IEC

300 V conforming to UL
[Uimp] rated impulse withstand voltage
4 kV 1.2/50 µs
Maximum switching voltage
250 V conforming to IEC
Maximum switching capacity
7500 VA/700 W
Minimum switching capacity
6000 mW (500 mA / 12 V) for NO
Operating rate
<= 18000 cycles/hour no-load

<= 1200 cycles/hour under load
Mechanical durability
5000000 cycles
Electrical durability
100000 cycles for resistive load
Average consumption
4 VA at 60 Hz
Drop-out voltage threshold
>= 0.15 Uc
Operating time
25 ms
Reset time
25 ms
Average resistance
15600 Ohm (tolerance +/- 15 %) at 20 °C
Safety reliability data
B10d = 100000
Protection category
RT II
Operating position
Any position
Product weight
0.082 kg
Device presentation
Complete product
Environment
Dielectric strength
2000 V AC between poles with basic insulation

1500 V AC between contacts with micro disconnection insulation

4000 V AC between coil and contact with reinforced insulation
Standards
EN/IEC 61810-1

UL 508

CSA C22.2 No 14
Product certifications
CE

CSA

GOST

UL
Ambient air temperature for storage
-40...85 °C
Ambient air temperature for operation
-40...55 °C
Vibration resistance
3 gn (+/- 1 mm, f = 10...150 Hz) 5 cycles in operation

10 gn (+/- 1 mm, f = 10...150 Hz) 5 cycles not operating
IP degree of protection
IP40 conforming to EN/IEC 60529
Shock resistance
10 gn in operation

30 gn not operating
Pollution degree
3
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:RPF2AP7

   Frequently Asked Questions and Answers


  • What is the base for the Zelio relay RPM22B7?

    The part name is as follows: RPZF2
    Read more

  • Compatibility Zelio Relays - LC1 contatactors

    Goals and Symptoms Compatibility Zelio Relays - LC1 contactors Facts and Changes RSB, RXM, RUM, RPM, RPF Causes and Fixes See the compatibility Relais-contatactors LC1 in attached file Attachments (Removed File URL: 202897_F286/Compatibility_Relays_-__LC1_contactors_-EN.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/c15014bdccbc8581c125775f003cba78/fl_block_5/0.524?OpenElement&FieldElemFormat=gif) Legacy KB System (APS) Data: RESL202897 V1.0, Originally a...
    Read more

  • What is the alternative for the RM4UA33MW zelio relay?

    The Zelio relay RM22UA33MR. Data sheet attached.   RM22UA33MR.pdf
    Read more

  • What is the Zelio relay SR1*201bd scan frequency?

    Issue: What is the Zelio relay SR1*201BD scan frequency? Product Line: Zelio Relays and Timers Environment: All Products Cause: Product Features Resolution: The cycle time is 8ms and has a response time of 14 - 26ms. CTA-ID : 2012071
    Read more

  • Are SR1 Zelio relays NPN/PNP selectable in the inputs?

    Issue: Are SR1 Zelio relays NPN/PNP selectable in the inputs? Product Line: Zelio Relays and Timers Environment: All Products Cause: Product Features Resolution: They are a PNP input only CTA-ID : 2002575
    Read more

Catalogue
  • file image Zelio Relay - Electromechanical relays Catalog (pdf) download image`
Certificate
  • file image EAC Certificate RPF (pdf) download image`
  • file image UL LISTED Certificate RPM, RUMC, RUMF, RXM, RPF (htm) download image`
  • file image UL LISTED Certificate RPM, RUMC, RUMF, RXM, RPF (htm) download image`
  • file image CSA Certificate RXM, RHK, RHN, RHZ, RPF (htm) download image`
  • file image UL Recognized RPF, RSL1, RPM, RSB, RUMC, RUMF, RXM (htm) download image`
  • file image UL Recognized RPF, RSL1, RPM, RSB, RUMC, RUMF, RXM (htm) download image`
Declaration of conformity
  • file image EU DOC - Zelio Relays RPF (pdf) download image`

Dimensions Drawings

Dimensions





Connections and Schema

Wiring Diagram



Symbols shown in blue correspond to Nema marking.



Performance Curves

Electrical Durability of Contacts
AC Resistive load



X
Switching capacity (kVA)
Y
Durability (number of operating cycles)
AC Reduction coefficient for inductive load (depending on power factor cos Ï•)

Durability (inductive load) = durability (resistive load) x reduction coefficient.



Y
reduction coefficient
Maximum switching capacity on DC resistive load



A
30 A
B
25 A

Note : These are typical curves, actual durability depends on load, environment, duty cycle, etc.



© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech