time delay relay 10 functions - 1 s..100 h - 12 V AC/DC - 1 OC

Main
Range of product
Zelio Time
Product or component type
Modular timing relay
Discrete output type
Relay
Width
17.5 mm
Device short name
RE17R
Time delay type
At

D

A

B

Ac

H

Ht

C

Bw

Di
Time delay range
1...10 s

6...60 s

10...100 h

1...10 h

0.1...1 s

6...60 min

1...10 min
Nominal output current
8 A
Complementary
Contacts material
Cadmium free
Control type
Selector switch on front panel
[Us] rated supply voltage
12 V AC/DC at 50/60 Hz
Voltage range
0.9...1.2 Us
Supply frequency
50...60 Hz (+/- 5 %)
Input voltage
5 V
Connections - terminals
Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable end

Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable end

Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable end

Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable end
Tightening torque
0.6...1 N.m conforming to IEC 60947-1
Housing material
Self-extinguishing
Repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
Temperature drift
+/- 0.05 %/°C
Voltage drift
+/- 0.2 %/V
Setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Impulse duration
100 ms with load in parallel typical

30 ms typical
Insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time
120 ms on de-energisation typical
On-load factor
100 %
Power consumption in VA
0...0.7 VA at 12 V AC
Power consumption in W
<= 0.5 W at 12 V DC
Minimum switching current
10 mA at 5 V DC
Maximum switching current
8 A AC/DC
Maximum switching voltage
250 V AC
Breaking capacity
<= 2000 VA
Operating rate in Hz
10 Hz
Electrical durability
100000 cycles for resistive load (8 A at 250 V AC maximum)
Mechanical durability
10000000 cycles
Dielectric strength
2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage
5 kV (1.2/50 µs)
Delay response
< 100 ms
Marking
CE
Creepage distance
4 kV/3 conforming to IEC 60664-1
Safety reliability data
MTTFd = 296.8 years

B10d = 270000
Mounting position
Any position in relation to normal vertical mounting plane
Mounting support
35 mm DIN rail conforming to EN/IEC 60715
Local signalling
LED indicator on steady: relay energised, no timing in progress

LED indicator flashing: timing in progress (80 % ON and 20 % OFF)

LED indicator pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) (5 % ON and 95 % OFF)
Product weight
0.07 kg
Environment
Immunity to microbreaks
<= 20 ms
Standards
EN 61000-6-4

EN 61000-6-1

2006/95/EC

IEC 61812-1

2004/108/EC

EN 61000-6-3

EN 61000-6-2
Product certifications
GL

cULus

CSA
Ambient air temperature for storage
-30...60 °C
Ambient air temperature for operation
-20...60 °C
IP degree of protection
IP20 (terminal block) conforming to IEC 60529

IP40 (housing) conforming to IEC 60529

IP50 (front panel) conforming to IEC 60529
Vibration resistance
20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Relative humidity
93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility
Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3

Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3

Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3

Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3

Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3

1.2/50 µs shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3

1.2/50 µs shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3

Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3

Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11

Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11

Conducted and radiated emissions conforming to EN 55022 class B
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
End of Life Information
Product end of life instructions
Available
Write Your Own Review
You're reviewing:RE17RMJU

   Frequently Asked Questions and Answers


Catalogue
  • file image Zelio Time Timing Relays catalog (pdf) download image`
Instruction sheet
  • file image RE17R... / RE17L.... Timing modular rlays with solid state or relay output, Instruction Sheet (pdf) download image`
Certificate
  • file image CCC Certificate Timer RE10 RE17 iRT (pdf) download image`
  • file image UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (htm) download image`
  • file image UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (htm) download image`
Declaration of conformity
  • file image EU DOC - Zelio Timer RE17 (pdf) download image`
End of life manual
  • file image RE17... Timer Relays, Product End-of-Life Instructions (pdf) download image`
REACh Declaration
  • file image time delay relay 10 functions - 1 s..100 h - 12 V AC/DC - 1 OC (pdf) download image`
RoHs Declaration
  • file image time delay relay 10 functions - 1 s..100 h - 12 V AC/DC - 1 OC (pdf) download image`

Dimensions Drawings

Width 17.5 mm





Connections and Schema

Internal Wiring Diagram





Wiring Diagram



1) Contact Y1:

  • Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.

  • Partial stop for functions At, Ht and Pt.

  • Function D if Di selected.

  • Not used for functions A, H and P.



Technical Description

Function A : Power on Delay Relay
Description

The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function Ac : On- and Off-Delay Relay with Control Signal
Description

After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes.

When control contact C re-opens, the timing T starts.

At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).

The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function At : Power on Delay Relay (Summation) with Control Signal
Description

After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.

Function: 1 Output



T = t1 + t2 +...



Function B : Interval Relay with Control Signal
Description

After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state.

Function: 1 Output





Function Bw : Double Interval Relay with Control Signal
Description

On closing and opening of control contact C, the output R closes for the duration of the timing period T.

Function: 1 Output





Function C : Off-Delay Relay with Control Signal
Description

After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function D : Symmetrical Flasher Relay (Starting Pulse Off)
Description

Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.

The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function Di : Symmetrical Flasher Relay (Starting Pulse On)
Description

Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.

The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function H : Interval Relay
Description

On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

Function: 1 Output



Function: 2 Outputs



2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)



Function Ht : Interval Relay (Summation) with Control Signal
Description

On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.

Pulsing or maintaining control contact C will again close the output R.

Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 +...

The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state.

Function: 1 Output



T = t1 + t2 +...



Legend

Relay de-energised

Relay energised

Output open

Output closed

C

Control contact

G

Gate

R

Relay or solid state output

R1/R2

2 timed outputs

R2 inst.

The second output is instantaneous if the right position is selected

T

Timing period

Ta -

Adjustable On-delay

Tr -

Adjustable Off-delay

U

Supply



© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech