LUCA1XBL
standard control unit LUCA - class 10 - 0.35...1.4 A - 24 V DC
SKU
LUCA1XBL
$276.55
User guide
CAD
Certificate
Declaration of conformity
End of life manual
Product environmental
REACh Declaration
RoHs Declaration
standard control unit LUCA - class 10 - 0.35...1.4 A - 24 V DC
[uc] control circuit voltage | 24 V |
---|---|
Control Circuit Voltage | 24 V |
thermal protection adjustment range | 0.35...1.4 A |
thermal overload class | Class 10 |
Write Your Own Review
Main
- Product or component type
- Standard control unit
- Product specific application
- Basic protection requirements for motor starters: overload and short-circuit
- Product compatibility
- ASILUFC5
ASILUFC51
LUFC00
LUFN.. - Utilisation category
- AC-41
AC-43
AC-44 - Motor power kW
- 0.25 kW at 400...440 V AC 50/60 Hz
- Thermal protection adjustment range
- 0.35...1.4 A
- [Uc] control circuit voltage
- 24 V DC
- Thermal overload class
- Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to IEC 60947-6-2
Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to UL 508 - Range
- TeSys
- Product name
- TeSys U
- Device short name
- LUCA
Complementary
- Function available
- Earth fault protection
Manual reset
Protection against overload and short-circuit
Protection against phase failure and phase imbalance - Mounting mode
- Plug-in
- Mounting location
- Front side
- Control circuit voltage limits
- 20...27 V for DC circuit 24 V in operation
- Typical current consumption
- 130 mA at 24 V DC I maximum while closing with LUB12
220 mA at 24 V DC I maximum while closing with LUB32
60 mA at 24 V DC I rms sealed with LUB12
80 mA at 24 V DC I rms sealed with LUB32 - Operating time
- 35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
70 ms closing with LUB12 for control circuit
70 ms closing with LUB32 for control circuit - Load type
- 3-phase motor - cooling: self-cooled
- Tripping threshold
- 14.2 x Ir +/- 20 %
- [Ui] rated insulation voltage
- 600 V conforming to CSA C22.2 No 14
600 V conforming to UL 508
690 V conforming to IEC 60947-1 - [Uimp] rated impulse withstand voltage
- 6 kV conforming to IEC 60947-6-2
- Safe separation of circuit
- 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 - Product weight
- 0.135 kg
Environment
- Heat dissipation
- 2 W for control circuit with LUB12
3 W for control circuit with LUB32 - Immunity to microbreaks
- 3 ms
- Immunity to voltage dips
- 70 % 500 ms conforming to IEC 61000-4-11
- Standards
- CSA C22.2 No 14 type E
EN 60947-6-2
IEC 60947-6-2
UL 508 type E with phase barrier - Product certifications
- ABS
ASEFA
ATEX
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
UL - IP degree of protection
- IP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1 - Protective treatment
- TH conforming to IEC 60068
- Ambient air temperature for operation
- -25...70 °C
- Ambient air temperature for storage
- -40...85 °C
- Operating altitude
- 2000 m
- Fire resistance
- 650 °C conforming to IEC 60695-2-12
960 °C parts supporting live components conforming to IEC 60695-2-12 - Shock resistance
- 10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27 - Vibration resistance
- 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-6
4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6 - Resistance to electrostatic discharge
- 8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2 - Resistance to radiated fields
- 10 V/m 3 conforming to IEC 61000-4-3
- Resistance to fast transients
- 2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 - Immunity to radioelectric fields
- 10 V conforming to IEC 61000-4-6
Offer Sustainability
- Sustainable offer status
- Green Premium product
- RoHS (date code: YYWW)
- Schneider Electric declaration of conformity
- REACh
- Reference not containing SVHC above the threshold
- Product environmental profile
- Product Environmental Profile
- Product end of life instructions
- End of Life Information
Contractual warranty
- Warranty period
- 18 months