power base - TeSys U - 32 A - screw clamps control

Main
Range
TeSys
Product name
TeSys U
Device short name
LUB
Product or component type
Non reversing power base
Device application
Motor
Poles description
3P
Suitability for isolation
Yes
[Ith] conventional free air thermal current
32 A
Utilisation category
AC-41

AC-43

AC-44
[Uc] control circuit voltage
110...220 V DC

110...240 V AC 50/60 Hz

24 V AC 50/60 Hz

24 V DC

48 V AC 50/60 Hz

48...72 V DC
Complementary
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1

Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
[Ue] rated operational voltage
230 V

440 V

500 V

690 V
Network frequency
40...60 Hz
[Ie] rated operational current
21 A at 690 V

23 A at 500 V

32 A at <= 440 V
[Ics] rated service breaking capacity
10 kA 500 V

4 kA 690 V

50 kA 230 V

50 kA 440 V
Typical current consumption
200 mA at 24 V DC I maximum while closing with LUCM

220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD

220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD

25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD

25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD

280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD

280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD

280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD

280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD

45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD

45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD

75 mA at 24 V DC I rms sealed with LUCM

80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD

90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
Safety reliability level
B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time
35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit

50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit

60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit

65 ms closing with LUCM for control circuit

70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
Mechanical durability
15000000 cycles
Operating rate
60 cyc/mn
[Ui] rated insulation voltage
600 V conforming to CSA C22.2 No 14

600 V conforming to UL 508

690 V conforming to IEC 60947-1 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N

400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Connections - terminals
Power circuit : screw clamp terminals 2 cable 1.5...6 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 1 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end

Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end

Control circuit : screw clamp terminals 2 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end

Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end

Power circuit : screw clamp terminals 1 cable 1...10 mm² - cable stiffness: rigid - without cable end

Power circuit : screw clamp terminals 1 cable 1...6 mm² - cable stiffness: flexible - with cable end

Power circuit : screw clamp terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end

Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: flexible - with cable end

Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: rigid - without cable end
Tightening torque
Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm flat

Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm Philips no 1

Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm flat

Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm Philips No 2
Width
45 mm
Height
145 mm
Depth
126 mm
Product weight
0.9 kg
Environment
Heat dissipation
3 W for control circuit with LUCA, LUCB, LUCC, LUCD

1.8 W for control circuit with LUCM
Immunity to microbreaks
3 ms
Immunity to voltage dips
70 % 500 ms conforming to IEC 61000-4-11
Product certifications
ABS

ASEFA

ATEX

BV

CCC

CSA

DNV

GL

GOST

LROS (Lloyds register of shipping)

UL
Standards
CSA C22.2 No 14 type E

EN 60947-6-2

IEC 60947-6-2

UL 508 type E with phase barrier
IP degree of protection
IP20 front panel and wired terminals conforming to IEC 60947-1

IP20 other faces conforming to IEC 60947-1

IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-25...60 °C with LUCM

-25...70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage
-40...85 °C
Fire resistance
650 °C conforming to IEC 60695-2-12

960 °C parts supporting live components conforming to IEC 60695-2-12
Operating altitude
2000 m
Shock resistance
10 gn power poles open conforming to IEC 60068-2-27

15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance
2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27

4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge
8 kV level 3 in open air conforming to IEC 61000-4-2

8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields
10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients
2 kV class 3 serial link conforming to IEC 61000-4-4

4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Non-dissipating shock wave
1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2

1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2

2 kV common mode 24...240 V AC conforming to IEC 60947-6-2

2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
Immunity to radioelectric fields
10 V conforming to IEC 61000-4-6
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:LUB32

   Frequently Asked Questions and Answers


  • Can the LUB32 use the smaller (less than 12 amps) control units?

    Issue:​ Can the LUB32 use the smaller (less than 12 amps) control units?  Product Line: Tesys U Line Motor Starters Environment: North American Products   Resolution: Yes, it can. That being said the LUB12 cannot use the larger (greater than 12 amps) control modules.
    Read more

  • Can the LUB12 with a LUCA*** control unit operate at 50hz ?

    Yes , the product control rating is 50/60Hz, the frequency limits are 40-60hz CTA-ID : 2054376
    Read more

  • Using TeSys U with Grounded Neutral

    Issue: Can the TeSys U motor starters be used on a single phase system with a grounded neutral? Product Line: TeSys U - GIC Product LUB12, LUB32 Environment: US Product Cause: Product Application Resolution: Yes, these starters can be used in this type of setup.  If the power wiring is grounded at the motor as well, an imbalance between hot and neutral can result which can cause nuisance tripping.
    Read more

  • What is the difference between an LUB12 32 & lub120 320 Tesys U starter?

    What is the difference between an LUB12 32 & LUB120 320 Tesys U starter? The Tesys U non reversing starter controller offers two types of power base units in its range LUB12 & LUB120 (0 – 12A, 5.5kw at 400V) LUB32 & LUB320 (0 – 32A, 15kW at 400V)   LUB12 & LUB32 power bases have gone through an evolutionary change. Pre 2010 wk36, the base unit was coloured black\white & the contact block LU9BN11 was removable. Post 2010 wk 36, the base unit is black, to de...
    Read more

  • What are the operating and storage temperatures for a TeSys U-line starter?

    Issue: What are the operating and storage temperatures for a U-line starter? Product Line:  Digest 177 Section 18 : Contactors and Starters IEC Environment: North American Products Resolution: Storage temperature: -40 to +185 degrees F (-40 to +85 degrees C). Operation: Power bases with standard and advanced control units: -13 to +158 degrees F (-25 to +70 degrees C). (At temperatures above 60ï¾°C and up to 70ï¾°C, for starter-controller LUB32, leave a minimum gap of 9 mm between products). Power...
    Read more

User guide
  • file image ASILUFC5-C51, AS-interface communication module (EN) (pdf) download image`
  • file image LULC031 Modbus communication module (pdf) download image`
  • file image TeSys U CANopen - Quick Start Guide (pdf) download image`
  • file image TeSysU Communication Variables (EN) (pdf) download image`
  • file image TeSys U - Use in explosive atmospheres (pdf) download image`
Instruction sheet
  • file image LUB.+LUCA/LUCB/LUCC/LUCD - TeSys U power base + control units (pdf) download image`
CAD
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith parallel link module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith AS-i communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith prewired control circuit components (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith multifunction control units (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith Modbus communication module (wmf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dwg) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (dxf) download image`
  • file image Starter-controlers on-reversing power baseswith phase barrier (wmf) download image`
  • file image SCREW CLAMP BASE (zip) download image`
  • file image SCREW CLAMP BASE (stp) download image`
Certificate
  • file image ATEX TeSys U - TeSys U Atex (pdf) download image`
Declaration of conformity
  • file image EU Declaration TeSys U - TeSys U (pdf) download image`
  • file image EU Declaration TeSys U - TeSys U Atex (pdf) download image`
End of life manual
  • file image TeSys U Power Base - EoLi (pdf) download image`
  • file image End-of-Life Instructions TeSys U (pdf) download image`
Product environmental
  • file image TeSys U, power base (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech