LC1K0910E7

$96.59
Special Order-Generally ships in 14 to 21 Business Days
SKU
LC1K0910E7

TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 48 V AC coil

Main
Range
TeSys
Product or component type
Contactor
Product name
TeSys K
Device short name
LC1K
Device application
Control
Contactor application
Motor control

Resistive load
Complementary
Utilisation category
AC-1

AC-3

AC-4
Poles description
3P
Pole contact composition
3 NO
[Ie] rated operational current
9 A at <= 440 V AC AC-3 for power circuit

20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit

16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
48 V AC 50/60 Hz
Motor power kW
2.2 kW at 400 V AC 50/60 Hz AC-4

2.2 kW at 220...230 V AC 50/60 Hz AC-3

4 kW at 380...415 V AC 50/60 Hz AC-3

4 kW at 440 V AC 50/60 Hz AC-3

4 kW at 480 V AC 50/60 Hz AC-3

4 kW at 500...600 V AC 50/60 Hz AC-3

4 kW at 660...690 V AC 50/60 Hz AC-3
Auxiliary contact composition
1 NO
Overvoltage category
III
[Ith] conventional free air thermal current
20 A at <= 50 °C for power circuit

10 A at <= 50 °C for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110

110 A AC for power circuit conforming to IEC 60947

110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
110 A at 415 V conforming to IEC 60947

110 A at 440 V conforming to IEC 60947

80 A at 500 V conforming to IEC 60947

110 A at 220...230 V conforming to IEC 60947

110 A at 380...400 V conforming to IEC 60947

70 A at 660...690 V conforming to IEC 60947
Associated fuse rating
25 A gG at <= 440 V for power circuit

25 A aM for power circuit

10 A gG for signalling circuit conforming to IEC 60947

10 A gG for signalling circuit conforming to VDE 0660
Average impedance
3 mOhm at 50 Hz - Ith 20 A for power circuit
Insulation resistance
> 10 MOhm for signalling circuit
Inrush power in VA
30 VA at 20 °C
Hold-in power consumption in VA
4.5 VA at 20 °C
Heat dissipation
1.3 W
Control circuit voltage limits
0.2...0.75 Uc at <= 50 °C drop-out

0.8...1.15 Uc at <= 50 °C operational
Operating rate
3600 cyc/h
Auxiliary contacts type
Type instantaneous (1 NO)
Signalling circuit frequency
<= 400 Hz
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Operating time
10...20 ms coil de-energisation and NO opening

10...20 ms coil energisation and NO closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance
0.5 mm
Mechanical robustness
Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27

Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27

Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27

Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27

Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27

Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27

Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6

Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Environment
Product certifications
CSA

UL
Protective treatment
TC conforming to IEC 60068

TC conforming to DIN 50016
Operating altitude
2000 m without derating in temperature
Flame retardance
V1 conforming to UL 94

Requirement 2 conforming to NF F 16-101

Requirement 2 conforming to NF F 16-102
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:LC1K0910E7

   Frequently Asked Questions and Answers


  • Is our Tesys K contactor a double break pole type contactor

    Tesys K (LC1K*) uses linear translation movement of contacts,hence double break pole type operation is obtained.
    Read more

  • Are the TeSys K 3 pole reversing mini-contactors and overloads designed with provision for panel and din rail mounting capacities?

    Issue: Are the TeSys K 3 pole reversing mini-contactors and overloads designed with provision for panel and din rail mounting capacities? Is there an accessory available that provides the separate mounting of the TeSys K overload modules which positions the overload block on the same din rail track as the contactor? Product Line: TeSys K 3 Pole Reversing & Non-Reversing Contactors, TeSys K accessories Environment: TeSys K Cause: Assembly/wiring Resolution: TeSys K mini-contactors are provided with...
    Read more

  • What does the *01 or *10 indicate at the end of the part number on the K-Line contactors?

    Issue: What does the *01 or *10 indicate at the end of the part number on the K-Line contactors? Product Line: TeSys K-Line Contactors Environment: All Product Lines Cause: The Digest does not specify. Resolution: the *10 will indicate a normally open auxiliary contact the *01 will indicate a normally closed auxiliary contact (example: LC1K0910 has one normally open auxiliary contact)
    Read more

  • Is the CA2KN22G7 DIN rail mountable?

    Issue: Is the CA2KN22G7 DIN rail mountable? Product Line: Industrial Relays Environment: Tesys K IEC Style Relays Cause: Determine how to mount for application.                              Resolution:                             ...
    Read more

  • Do you offer a remote reset for LR2K overload relays?

    Issue: Do you offer a remote reset for LR2K overload relays? Product Line: TeSys K Overload Relays Environment: All Product Lines Cause: Can not find it in the Digest Resolution: We do not offer a remote reset for the LR2K overload relays.
    Read more

Catalogue
  • file image Tesys catalogue 2018 - Motor control and protection components (pdf) download image`
Instruction sheet
  • file image LC1-K contactor (pdf) download image`
CAD
  • file image CONTACTOR (zip) download image`
  • file image CONTACTOR (pdf) download image`
  • file image CONTACTOR (stp) download image`
Certificate
  • file image CCC Cert TeSys K - LC.K-LP.K, Indonesia (pdf) download image`
  • file image CCC Cert TeSys K - LC.K,LP.K, LC1KT, France (pdf) download image`
  • file image CB TeSys K - LC.K-LP.K (pdf) download image`
Declaration of conformity
  • file image EU Declaration TeSys K - LC.K-LP.K (pdf) download image`
End of life manual
  • file image TeSys LC1K09-K16 - EoLi (pdf) download image`
Product environmental
  • file image TeSys LC1K09-K16 - PEP (pdf) download image`
REACh Declaration
  • file image TeSys K contactor - 3P - AC-3 download image`
RoHs Declaration
  • file image TeSys K contactor - 3P - AC-3 download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech