LAD96560

$19.33
Generally ships in 1 to 2 days
SKU
LAD96560

Everlink Size 3 Power Termination Block

Main
Range
TeSys
Device short name
LAD9
Product or component type
Terminal block
Accessory / separate part category
Connection accessory
Poles description
3P
Product compatibility
LC1D40A...D65A

LR3D3

LRD3

LRD3..L
Complementary
Connections - terminals
EverLink BTR screw connectors
Product weight
0.087 kg
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:LAD96560

   Frequently Asked Questions and Answers


  • Is it possible to use TeSys GV2 and TeSys GV3 Range MPCB in DC applications.

    The TeSys GV2 and TeSys GV3 range MPCB can be used in DC applications as per their technical specifications.  Refer the below wiring connection for TeSys GV range MPCB in DC network.     1.jpg
    Read more

  • Is it possible to use the current Limiter la9lb920 or GV1L3 with Tesys GV3 range of MPCB to increase the breaking capacity.

    LA9LB920 and GV1L3 current limiter are dedicated to Tesys GV2 Motor Protection Circuit Breaker (MPCB) product range and can be used with MPCB rated up to 32A (maximum current range of Tesys GV2 products).   The new Tesys GV3 range does not have current limiter to increase its breaking capacity.   If higher breaking capacity for Tesys GV3 is needed, use in association with fuses can increase the breaking capacity of the system up to the fuse performance breaking capacity.
    Read more

  • What is the significance of two arrows on the knob of Tesys GV3P Current Setting Dial.

    The first black arrow needs to be set at the rated current of Motor, when Tesys GV3 MPCB is used with contactor separately mounted or not used at all.   The second white arrow needs be set at rated current of Motor, when the Tesys GV3 MPCB and contactor are used in combination. This setting gives allowance for the heat dissipation in the thermal characteristics of MPCB due to the combined use of the Tesys GV3P and Tesys LC1D at the rated current.   See below diagram for clarity.
    Read more

  • r030_Nuisance tripping on TeSys GV and LRD

    Goals and Symptoms Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Facts and Changes Nuisance tripping, LRD, GV2, GV3, GV7 Causes and Fixes Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Attachments (Removed File URL: 191721_5CB2/R030_How_to_trouble_Shoot_a_Nuisance_tripping_on_GV_and_LRD.pdf)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/92d280a779478116c125757d00422c40/fl_bl...
    Read more

  • What is the part number for padlock device for GV3ME motor CB?

      The part number for padlock device for GV3ME motor CB is GV1V02 GV1V02  TeSys GV3 - padlocking device
    Read more

Instruction sheet
  • file image LRD3.., LRD3..3, LRD3..L, LRD3..L3, LR3D3.., LR3D3..3 - Everlink 3-pole thermal overload relays 18.5 to 37 kW (pdf) download image`
Technical leaflet
  • file image Control Panel Technical Guide - How to quickly design optimized contactor assemblies (pdf) download image`
CAD
  • file image D40A-D65A EVERLINK TERMINAL BLOCK 3P (zip) download image`
  • file image D40A-D65A EVERLINK TERMINAL BLOCK 3P (stp) download image`
End of life manual
  • file image End-of-Life Instructions TeSys GV3P (pdf) download image`
Product environmental
  • file image TeSys GV3 motor circuit breakers (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech