K50B001UP

$235.62
Special Order-Generally ships in 14 to 21 Business Days
SKU
K50B001UP

cam changeover switch - 1 pole - 60° - 50 A - screw mounting

Main
Range of product
Harmony K
Product or component type
Complete cam switch
Component name
K50
[Ith] conventional free air thermal current
50 A
Mounting location
Front
Fixing mode
4 holes
Cam switch head type
With front plate 64 x 64 mm
Type of operator
Black handle
Rotary handle padlocking
Without
Presentation of legend
With metallic legend, 1 - 0 - 2 black marking
Cam switch function
Changeover switch
Return
Without
Off position
With Off position
Poles description
1P
Switching positions
Left: 0° - 300°

Right: 0° - 60°
IP degree of protection
IP40 conforming to IEC 529

IP40 conforming to NF C 20-010
Complementary
CAD overall height
64 mm
CAD overall depth
85 mm
Product weight
0.215 kg
Switching angle
60 °
[Ui] rated insulation voltage
690 V degree of pollution 3 conforming to EN 60947-1

690 V degree of pollution 3 conforming to IEC 60947-1
Short-circuit current
5000 A
Short-circuit protection
63 A by cartridge fuse, type gG
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 947-1

6 kV conforming to IEC 947-1
Contact operation
Slow-break
Positive opening
With
Electrical connection
Captive screw clamp terminals flexible, 2 x 6 mm²

Captive screw clamp terminals solid, 2 x 10 mm²
Tightening torque
2 N.m
Switching capacity in mA
15000 mA DC at 120 V 2 contact(s) for inductive load (T = 50 ms)

15000 mA DC at 180 V 3 contact(s) for inductive load (T = 50 ms)

15000 mA DC at 60 V 1 contact(s) for inductive load (T = 50 ms)

20000 mA DC at 140 V 3 contact(s) for inductive load (T = 50 ms)

20000 mA DC at 48 V 1 contact(s) for inductive load (T = 50 ms)

20000 mA DC at 95 V 2 contact(s) for inductive load (T = 50 ms)

30000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms)

30000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms)

30000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms)

3500 mA DC at 110 V 1 contact(s) for inductive load (T = 50 ms)

3500 mA DC at 220 V 2 contact(s) for inductive load (T = 50 ms)

3500 mA DC at 330 V 3 contact(s) for inductive load (T = 50 ms)

37000 mA DC at 120 V 2 contact(s) for resistive load (T = 1 ms)

37000 mA DC at 180 V 3 contact(s) for resistive load (T = 1 ms)

37000 mA DC at 60 V 1 contact(s) for resistive load (T = 1 ms)

40000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms)

40000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms)

40000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms)

40000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms)

40000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms)

40000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms)

50000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms)

50000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms)

50000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms)
Mechanical durability
300000 cycles
CAD overall width
64 mm
Environment
Standards
EN/IEC 60947-3
Product certifications
CULus 120 V 3 hp 1 phase

CULus 480 V 25 hp 3 phases

CULus 240 V 7.5 hp 1 phase

CULus 240 V 7.5 hp 3 phases
Protective treatment
TC
Ambient air temperature for operation
-25...55 °C
Ambient air temperature for storage
-40...70 °C
Overvoltage category
Class II conforming to IEC 60536

Class II conforming to NF C 20-030
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:K50B001UP

   Frequently Asked Questions and Answers


Certificate
  • file image K10, K30, K50, K63, K115, K150 Cam switches (html) download image`
  • file image K1 K2 K10 K30 K50 K63 K115 K150 Cam switches (pdf) download image`
Declaration of conformity
  • file image K30, K50, K63, K115, K150 Cam switches (pdf) download image`

Dimensions Drawings

Dimensions
Front Mounting



e
support panel thickness 0.5 to 5.5 mm / 0.02 to 0.22 in in.

a

b

c

D1

mm

in.

mm

in.

mm

in.

mm

in.

45.8

1.80

60

2.36

64

2.52

4.1

0.16



Mounting and Clearance

Panel Cut-Out
Front Mounting



D2

D3

G1

mm

in.

mm

in.

mm

in.

4.5

0.18

10

0.39

48

1.89



Technical Description

Link Positions (Factory Mounted)
Diagram for 1 to 4-pole Switches

Select the number of poles according to the product characteristics



I1
Input 1
I2
Input 2


Marking





Angular Position of Switch





Switching Program



(1)
1-pole
(2)
2-pole
(3)
3-pole
(4)
4-pole


Convention Used for Switching Program Representation

Contact closed

Contact closed in 2 positions and maintained between the 2 positions

Sealed assembly for auto-maintain control

Overlapping contacts

Spring return position: for a switching angle of 90°, spring return is over 30° after the last position (for a maximum of 3 simultaneous contacts).

Example:





© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech