3”5 color touch controller panel - Dig 16 inputs/10 outputs

Main
Range of product
Magelis SCU
Product or component type
Controller
Device presentation
Basic element
Complementary
Supply
External source
[Us] rated supply voltage
24 V at 20.4...28.8 V DC
Immunity to microbreaks
<= 10 ms
Inrush current
<= 30 A
Power consumption in W
15 W
Local signalling
No indicator
Number of pages
Limited by internal memory capacity
Software designation
SoMachine
Operating system
Magelis
Processor name
CPU RISC
Processor frequency
333 MHz
Memory description
128 MB flash memory, type: NAND

128 kB internal data storage memory, type: FRAM

128 MB application run memory, type: DRAM
Integrated connection type
1 RJ45 connector serial link with RS232/RS485 interface at <= 115.2 kbits/s

1 RJ45 connector Ethernet TCP/IP

1 USB 2.0 type mini B

1 USB 2.0 type A

SUB-D 9 connector CANopen master bus
Realtime clock
Built-in
Downloadable protocols
Modbus

Modbus TCP/IP

CANopen
Fixing mode
By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel
Enclosure material
PC/PBT
Shock resistance
147 m/s² (duration=11 ms) conforming to IEC 60068-2-27 on DIN rail

294 m/s² (duration=6 ms) conforming to IEC 60068-2-27 on panel mounting
Vibration resistance
+/- 3.5 mm (f=5...9 Hz) conforming to IEC 60068-2-6

1 gn (f=9...150 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 8 kV, air discharge conforming to IEC 61000-4-2

Electrostatic discharge immunity test - test level: 6 kV, contact discharge conforming to IEC 61000-4-2

Susceptibility to electromagnetic fields - test level: 10 V/m, 80 MHz...3 GHz conforming to IEC 61000-4-3

Electrical fast transient/burst immunity test - test level: 2 kV, power lines conforming to IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 1 kV, between analogue I/O and operating voltage conforming to IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 2 kV, relay wires conforming to IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 1 kV, Ethernet line conforming to IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 1 kV, COM line conforming to IEC 61000-4-4

Electrical fast transient/burst immunity test - test level: 1 kV, CAN line conforming to IEC 61000-4-4

Surge immunity test - test level: 2 kV, power supply (common mode) conforming to IEC 61000-4-5

Surge immunity test - test level: 1 kV, power supply (differential mode) conforming to IEC 61000-4-5

Surge immunity test - test level: 1 kV common mode, digital I/O conforming to IEC 61000-4-5

Surge immunity test - test level: 0.5 kV differential mode, digital I/O conforming to IEC 61000-4-5

Conducted RF disturbances - test level: 10 V, 0.15...80 MHz conforming to IEC 61000-4-6

Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011

Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011
Discrete input number
2 for fast input (normal mode) conforming to IEC 61131-2 Type 1

6 for digital input conforming to IEC 61131-2 Type 1
Discrete input voltage
24 V DC discrete input logic:sink or source (positive/negative)
Number of common point
1 for fast input (HSC mode)

1 for digital input
Discrete input current
7.83 mA for fast input

5 mA for digital
Input impedance
4.7 kOhm

2.81 kOhm
Sensor power supply
15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1.5 mA

15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 2.5 mA, voltage (state 0): <= 5 V, current (state 0): <= 1 mA
Configurable filtering time
0 ms no filter (none)

0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2))

3...12 ms integrator (none/run/stop)
Input frequency
100 kHz for fast input (encoder mode) - control type A/B

100 kHz for fast input - control type single phase

100 kHz for fast input - control type pulse/direction
Cable distance between devices
Shielded cable: 10 m for fast input

Shielded cable: 100 m for digital input

Unshielded cable: 50 m for digital input
Connection pitch
3.5 mm
Overvoltage protection
With
Isolation between channels and internal logic
500 V DC
Isolation between channels
None
Discrete output number
2 fast output (normal mode), output logic: source

6 digital output, output logic: source
Discrete output voltage
24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s)

24 V DC (voltage limit: 5...30 V) with relay discrete output(s)

220 V AC (voltage limit: 100...250 V) with relay discrete output(s)
Input/output number
2 for fast input, terminal(s): FI0...FI1

2 for fast output, terminal(s): FQ0...FQ1

6 for digital input, terminal(s): DI0...DI5

6 for digital output, terminal(s): DQ0...DQ5
Discrete output current
300 mA, response time 2 ms for fast output (normal mode)

50 mA, response time 2 ms for fast output (PWM or PTO mode)

2 A (current per output common:4 A), response time 5 ms with opening contact for digital output

2 A (current per output common:4 A), response time 2 ms with closing contact for digital output
Insulation resistance
> 10 MOhm between the I/O and internal logic

> 10 MOhm between power supply and earth
Output frequency
<= 100 kHz for fast output (PTO mode)

<= 1 kHz for fast output (PWM mode)
Absolute accuracy error
+/- 0.1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode)

1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode)

+/- 5 % of full scale of cyclic ratio 10...90% for fast output (PWM or PTO mode)

+/- 10 % of full scale of cyclic ratio 20...80% for fast output (PWM or PTO mode)

+/- 15 % of full scale of cyclic ratio 30...70% for fast output (PWM or PTO mode)
Analogue input number
2 for analog input

2 for RTDs
Analogue input range
0...20 mA/4...20 mA - resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %)

-10...+10 V or 0...10 V - resolution: 12 bits + sign, input impedance: >= 1 MOhm
Analogue input type
RTD at - 200...600 °C - resolution: 16 bits temperature probe: Pt 100/Pt 1000

RTD at - 50...200 °C - resolution: 16 bits temperature probe: Ni 100/Ni 1000

RTD at - 200...760 °C - resolution: 16 bits (thermocouple J)

RTD at - 240...1370 °C - resolution: 16 bits (thermocouple K)

RTD at 0...1600 °C - resolution: 16 bits (thermocouple R)

RTD at 200...1800 °C - resolution: 16 bits (thermocouple B)

RTD at 0...1600 °C - resolution: 16 bits (thermocouple S)

RTD at - 200...400 °C - resolution: 16 bits (thermocouple T)

RTD at - 200...900 °C - resolution: 16 bits (thermocouple E)

RTD at - 200...1300 °C - resolution: 16 bits (thermocouple N)
Analogue output number
2 resistive load for 12 bits + sign
Analogue output range
0...20 mA/4...20 mA (> 300 Ohm) for open-circuit

-10...10 V/0...10 V (> 2 kOhm) for short-circuit
Height
50.65 mm
Width
128 mm
Depth
102 mm
Product weight
0.398 kg
Environment
Standards
EN 61131-2

FCC Class A

IEC 61000-6-2

RoHS compliant

UL 508

ANSI/ISA 12-12-01

WEEE directive 2002/96/EC

CSA C22.2 No 213 Class I Division 2

RoHS China SJ/T 11363-2006
Product certifications
C-Tick

CULus 508

GOST

CUL 1604 Class 1 Division 2

KCC

CULus CSA 22-2 No 142
Marking
CE
Ambient air temperature for operation
0...50 °C
Ambient air temperature for storage
-20...60 °C
Relative humidity
5...85 % without condensation
Operating altitude
<= 2000 m
Storage altitude
0...10000 m
Maximum pressure
800...1114 hPa
IP degree of protection
IP65 for front panel conforming to IEC 60529

IP20 for rear panel conforming to IEC 60529
NEMA degree of protection
NEMA 4X for front panel
Pollution degree
2 conforming to IEC 60664
Environmental characteristic
Corrosive gas free
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Write Your Own Review
You're reviewing:HMISCU6A5

   Frequently Asked Questions and Answers


  • What is the minimum version of SoMachine and Vijeo Designer that supports HMISCU6A5, HMISCU8A5, HMISCU6B5 and HMISCU8B5?

    Magelis SCU (HMISCU6A5, HMISCU8A5, HMISCU6B5, HMISCU8B5) is available in SoMachine software version V3.1 and VijeoDesigner V6.1 with SP3.1 installed.
    Read more

  • Does the Magelis hmiscuxa5/hmiscuxb5 support drivers for Emerson Process Management?

     Title  Does the Magelis HMISCUxA5/HMISCUxB5 support drivers for Emerson Process Management?  Issue   Product Line Magelis HMISCU6A5; HMISCU6B5; HMISCU8A5; HMISCU8B5 Environment   Cause Resolution The Magelis HMISCU targets does not support drivers from Emerson Process Management.  The third party drivers are are supported by the HMISCU are: Generic, Omron, Rockwell, Siemens.
    Read more

  • What are the part numbers for SoMachine version 4.3?

    Issue: Need to know the part numbers for the programming Software SoMachine version 4.3. Product Line: PLC Programming software Resolution: The part numbers for SoMachine version 4.3 are: - SOMNACS43 + trial license for V4.3 (21days) - USB flash drive. The USB flash drive is mandatory and supplied with a trial license. - SOMNACCZXSPAZZ 1 (Single License) - SOMNACCZXTPAZZ 10 (Team License) - SOMNACCZXEPAZZ 100 (Entity License) Supported controllers: - Logic controllers: Modicon M238, Modicon M241, Mod...
    Read more

  • There is a download security set on my Magelis HMI, but I do not remember the password in order to be able to download to it. How can I recover or download an application to the target?

    Issue There is a download security set on my Magelis HMI, but I do not remember the password in order to be able to download to it.  How can I recover or download an application to the target? Product Line Magelis XBTGK/GT/GC/GH, HMIGTO/GTU/STO/STU/SCU, iPC, Box PC, Panel PC Environment Windows XP, Windows 7, Windows 10 Resolution There is no method to recover the password from the Magelis HMI, however new Security Settings can be downloaded to the HMI. Option 1: Modify the security settings in t...
    Read more

  • Are there any IO expansions for the Magelis HMISCU HMI controller?

    Issue: Are there any IO expansions for the Magelis HMISCU HMI controller? Product Line: HMISCU, HMISCU8B5, HMISCU8A5, HMISCU6B5, HMISCU6A5, IO expansion, I/O expansion Resolution: The HMISCU does not have any IO expansion modules that connect directly to it. The options would be to use: Advantys OTB island Advantys STB island use a small PLC (M221) with a Magelis (HMISTU) instead of the HMISCU.   There are three Advantys OTB options (they differ in terms of connectivity to the PLC): OTB1C0DM9LP ...
    Read more

User guide
  • file image Magelis SCU - HMI Controller, Quick Reference Guide (pdf) download image`
  • file image Magelis SCU - HMI Controller, PTO/PWM Library Guide (pdf) download image`
  • file image Magelis SCU - HMI Controller, PLCSystem Library Guide (pdf) download image`
  • file image Magelis SCU - HMI Controller, HSC Library Guide (pdf) download image`
  • file image Magelis SCU - HMI Controller, Quick Reference Guide (pdf) download image`
  • file image Magelis SCU HMI Controller, Hardware Guide (pdf) download image`
  • file image Magelis SCU - HMI Controller, Programming guide (pdf) download image`
Catalogue
  • file image Magelisâ„¢ SCU Small HMI Controllers (pdf) download image`
Instruction sheet
  • file image HMIZSURDP.. Remote Controller Module Connection Cable, Instruction Sheet (pdf) download image`
  • file image Magelis HMISTU and HMISCU Terminals ATEX/IECEx, Instruction Guide (pdf) download image`
CAD
  • file image Compact CANopen HMI Controller SCU - - Wiring Diagram (zip) download image`
Certificate
  • file image HazLoc_cUL_NRAG7.E486185 _ALL_JUL2018 (pdf) download image`
  • file image HazLoc_UL_NRAG.E486185 _ALL_JUL2018 (pdf) download image`
Marine certificate
  • file image LR_C1210041E2_GTO_STO_SCU_STU_XBTGT (pdf) download image`
REACh Declaration
  • file image 3”5 color touch controller panel - Dig 16 inputs/10 outputs (pdf) download image`
RoHs Declaration
  • file image 3”5 color touch controller panel - Dig 16 inputs/10 outputs (pdf) download image`
System user guide
  • file image Compact CANopen HMI Controller SCU (pdf) download image`
  • file image Compact CANopen HMI Controller SCU (zip) download image`

Dimensions Drawings

Dimensions





Mounting and Clearance

Recommended Mounting position



(1)
Horizontal mounting
(2)
Vertical mounting


No Recommended Mounting Position





Mounting on a Slanted Panel



(1)
30° or less


Clearance



Keep adequate spacing for proper ventilation to maintain an ambient temperature between 0...50 °C (32...122 °F) for horizontal installation and 0...40 °C (32...104 °F) for vertical installation.



Connections and Schema

Wiring Diagram



(1)
Slow-blow 2A type T fuse


Wiring Diagram of Digital Inputs



(1)
HSC inputs with pin assignment of terminal blocks C,D.
(2)
Digital inputs with pin assignment of terminal blocks C,D.


Wiring Diagram of Digital Outputs



(1)
Digital outputs with pin assignment of terminal blocks A,B.
(2)
PWM outputs with pin assignment of terminal blocks C,D.
(L)
Load


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech