GV2MC02

$89.43
Generally ships in 1 to 2 days
SKU
GV2MC02

TeSys GV2 - Enclosure for TeSys GV2ME - IP55

Main
Range
TeSys
Product or component type
Enclosure
Device short name
GV2MC
Accessory / separate part category
Mounting accessory
Product compatibility
GV2ME
Enclosure/cubicle description
Surface mounting
Complementary
Auxiliary mounting location
Left

Right
Height
147 mm
Width
93 mm
Depth
84 mm
Product weight
0.3 kg
Environment
IP degree of protection
IP55
Environmental characteristic
Standard environment
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:GV2MC02

   Frequently Asked Questions and Answers


  • Is it possible to use TeSys GV2 and TeSys GV3 Range MPCB in DC applications.

    The TeSys GV2 and TeSys GV3 range MPCB can be used in DC applications as per their technical specifications.  Refer the below wiring connection for TeSys GV range MPCB in DC network.     1.jpg
    Read more

  • Is it possible to use the current Limiter la9lb920 or GV1L3 with Tesys GV3 range of MPCB to increase the breaking capacity.

    LA9LB920 and GV1L3 current limiter are dedicated to Tesys GV2 Motor Protection Circuit Breaker (MPCB) product range and can be used with MPCB rated up to 32A (maximum current range of Tesys GV2 products).   The new Tesys GV3 range does not have current limiter to increase its breaking capacity.   If higher breaking capacity for Tesys GV3 is needed, use in association with fuses can increase the breaking capacity of the system up to the fuse performance breaking capacity.
    Read more

  • r030_Nuisance tripping on TeSys GV and LRD

    Goals and Symptoms Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Facts and Changes Nuisance tripping, LRD, GV2, GV3, GV7 Causes and Fixes Use this troubleshooting guide if you experience nuisance tripping on TeSys GV and TeSys LRD Attachments (Removed File URL: 191721_5CB2/R030_How_to_trouble_Shoot_a_Nuisance_tripping_on_GV_and_LRD.pdf)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/92d280a779478116c125757d00422c40/fl_bl...
    Read more

  • What is the replacement for gv1m10?

    The replacement for GV1M10 is GV2ME10. GV2ME10  TeSys GV2-Circuit breaker-thermal-magnetic - 4...6.3 A - screw clamp terminals  For more information see: https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=GV2ME10
    Read more

  • Can GVAU225 operate on 60 HZ?

    No GVAU225 cannot be used on 60 HZ but GVAU226 can. GVAU226  TeSys GV2 & GV3 - undervoltage trip - 220...240 V AC 60 Hz For further information see;https://www.schneider-electric.com.au/en/product-range-selector/684-tesys-gv2/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D684%26prd_id%3DGVAU226%26scp_id%3DAU_en
    Read more

Instruction sheet
  • file image Instruction sheet - GV2 MC/MP Enclosures and accessories (pdf) download image`
CAD
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dwf) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dwg) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dxf) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (wmf) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dwf) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dwg) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (dxf) download image`
  • file image Enclosures for thermal-magnetic circuit-breakers GV2 ME, double insulated with protective, L=93 mm H=147 mm P=84 mm, surface mounting (wmf) download image`
  • file image SURFACE MOUNTING.ENCLOSURE (zip) download image`
  • file image SURFACE MOUNTING.ENCLOSURE (stp) download image`
  • file image TeSys GV2 - Enclosure for TeSys GV2ME (pdf) download image`
  • file image TeSys GV2 - Enclosure for TeSys GV2ME (stp) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech