Dimensions in mm
b | c | H |
---|---|---|
130 | 131.2 | 120 |
Dimensions in in.
b | c | H |
---|---|---|
5.12 | 5.16 | 4.72 |
Dimensions in mm
c1 |
---|
63 |
Dimensions in in.
c1 |
---|
2.48 |
Issue: What is part number for an EMC filter for the Altivar 12 drives? Product Line: Altivar 12, ATV12, ATV11 Environment: ATV12H018F1 ATV12H037F1 ATV12H018M2 ATV12H037M2 ATV12H055M2 ATV12H075M2 ATV12P037F1 ATV12P037M2 ATV12P055M2 ATV12P075M2 Cause: EMC Filter Resolution: Part number VW3A4416 is an externally mounted EMC filter that will fit these drives.
Read more
Issue: What does the scrolling LEDs mean on the ATV312? Product Line: Altivar 312, Altivar 12 Environment: All serial numbers Cause: N/A Resolution: The scrolling LEDs mean the drive is in Local Operation mode. To switch into Local Programming, push and hold the ESC button for 2s. Then all three LED's will be flashing at the same time and the programming can be changed. When programming is finished, push and hold the ESC button again for 2s to en...
Read more
Issue: What size speed potentiometer to use on Schneider Electric VFDs? Product Line: Altivar 61, Altivar 71, Altivar 312, Altivar 12, Altivar 212, Altivar 32, Altivar 58 Environment: All serial numbers Cause: N/A Resolution: The Schneider Electric VFDs will work with any potentiometer with a rating from 1k Ohms to 10k Ohms.
Read more
What Communication option are standard on the Schneider drives? Issue: What Communication option are standard on the Schneider drives? Product Line: ALTIVAR 61, ALTIVAR 71, ALTIVAR 312, ALTIVAR 32, ALTIVAR 212, ALTIVAR 12, Environment: All drives all serial number Cause: N/A Resolution : The standard communication protocols are Modbus on all Schneider Drives. However, on the ALTIVAR 61, ALTIVAR 71, ALTIVAR 312, and ALTIVAR 32, CanOpen is standard.
Read more
What causes FST on the display of the Altivar drives? Issue: What causes FST on the display of the Altivar drives? Product Line: Altivar 61, Altivar 71, Altivar 312, Altivar 12, Altivar 31, Altivar 58, Altivar 66 Environment: All serial number Cause: What causes the drive status to show FST? Resolution: FST is fast stop. This status happens if a logic input is assigned to FST and the logic input is active. The second option is when the VFD is in a deceleratin...
Read more
Dimensions in mm
b | c | H |
---|---|---|
130 | 131.2 | 120 |
Dimensions in in.
b | c | H |
---|---|---|
5.12 | 5.16 | 4.72 |
Dimensions in mm
c1 |
---|
63 |
Dimensions in in.
c1 |
---|
2.48 |
Remove the protective cover from the top of the drive.
Remove the protective cover from the top of the drive.