ATS48C66Q
soft starter for asynchronous motor - ATS48 - 605 A - 230..415 V - 160..500 KW
SKU
ATS48C66Q
$19,144.13
Software - Released
User guide
Catalogue
CAD
Certificate
Marine certificate
Product environmental
soft starter for asynchronous motor - ATS48 - 605 A - 230..415 V - 160..500 KW
motor power kW | 160 kW, 315 kW, 355 kW, 400 kW, 500 kW |
---|---|
Icl nominal current | 660 A, 1143 A |
Write Your Own Review
Main
- Range of product
- Altistart 48
- Product or component type
- Soft starter
- Product destination
- Asynchronous motors
- Product specific application
- Heavy duty industry and pumps
- Device short name
- ATS48
- [Us] rated supply voltage
- 230...415 V (- 15...10 %)
- Motor power kW
- 160 kW at 230 V (connection in the motor supply line) for severe applications
315 kW at 230 V (connection to the motor delta terminals) for standard applications
315 kW at 400 V (connection in the motor supply line) for severe applications
355 kW at 400 V (connection in the motor supply line) for standard applications
400 kW at 400 V (connection to the motor delta terminals) for severe applications
500 kW at 400 V (connection to the motor delta terminals) for standard applications - Power dissipation in W
- For standard applications 1731 W
For severe applications 1958 W - Utilisation category
- AC-53A
- Type of start
- Start with torque control (current limited to 5 In)
- IcL starter rating
- 660 A (connection in the motor supply line) for severe applications
660 A (connection in the motor supply line) for standard applications
1143 A (connection to the motor delta terminals) for standard applications
1143 A (connection to the motor delta terminals) for severe applications - IP degree of protection
- IP00
Complementary
- Assembly style
- With heat sink
- Function available
- External bypass (optional)
- Supply voltage limits
- 195...456 V
- Supply frequency
- 50...60 Hz (- 5...5 %)
- Network frequency
- 47.5...63 Hz
- Device connection
- In the motor supply line
To the motor delta terminals - Factory setting current
- 605 A
- [Uc] control circuit voltage
- 220 - 15 % to 415 + 10 %, 50/60 Hz
- Control circuit consumption
- 80 W
- Discrete output number
- 2
- Discrete output type
- (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO - Output absolute accuracy precision
- +/- 5 %
- Minimum switching current
- Relay outputs 10 mA at 6 V DC
- Maximum switching current
- Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms - Discrete input number
- 5
- Discrete input type
- PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm - Discrete input voltage
- 24 V (<= 30 V)
- Discrete input logic
- Positive logic (Stop, Run, LI3, LI4) state 0 < 5 V and <= 2 mA, state 1 > 11 V and >= 5 mA
- Supply inrush current
- Adjustable 0.4...1.3 Icl
- Analogue output type
- (AO) current output 0-20 mA or 4-20 mA <= 500 Ohm
- Communication port protocol
- Modbus
- Connector type
- 1 RJ45
- Communication data link
- Serial
- Physical interface
- RS485 multidrop
- Transmission rate
- 4800, 9600 or 19200 bps
- Installed device
- 31
- Protection type
- Phase failure (line)
Thermal protection (motor)
Thermal protection (starter) - Marking
- CE
- Type of cooling
- Forced convection
- Operating position
- Vertical +/- 10 degree
- Height
- 670 mm
- Width
- 400 mm
- Depth
- 300 mm
- Product weight
- 51.4 kg
- Power range
- 110...220 kW at 200...240 V 3 phases
250...500 kW at 380...440 V 3 phases
250...500 kW at 200...240 V 3 phases - Motor starter type
- Soft starter
Environment
- Electromagnetic compatibility
- Conducted and radiated emissions conforming to IEC 60947-4-2 level A
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Electrostatic discharge conforming to IEC 61000-4-2 level 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3
Voltage/current impulse conforming to IEC 61000-4-5 level 3 - Standards
- EN/IEC 60947-4-2
- Product certifications
- CCC
CSA
C-Tick
DNV
GOST
NOM 117
SEPRO
TCF
UL - Vibration resistance
- 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6 - Shock resistance
- 15 gn for 11 ms conforming to EN/IEC 60068-2-27
- Noise level
- 55 dB
- Pollution degree
- Level 3 conforming to IEC 60664-1
- Relative humidity
- 0...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
- Ambient air temperature for operation
- 40...60 °C with current derating of 2 % per °C
-10...40 °C without derating - Ambient air temperature for storage
- -25...70 °C
- Operating altitude
- <= 1000 m without derating
> 1000...2000 m with current derating of 2.2 % per additional 100 m
Contractual warranty
- Warranty period
- 18 months