ABE7S16E2E0

$1,360.51
Special Order-Generally ships in 14 to 21 Business Days
SKU
ABE7S16E2E0

sub-base - soldered solid state output relay ABE7 - 16 inputs - 48 V AC

Main
Product or component type
Solid state input relay sub-base
[Us] rated supply voltage
24 V DC (PLC end)

48 V AC 50/60 Hz (sensor end)
Number of channels
16
Number of terminal per channel
2
Connections - terminals
Screw type terminals, clamping capacity: 1 x 0.09...1 x 1.5 mm², cable cross section: 0.09...1.5 mm² AWG 28...AWG 16 flexible with cable end

Screw type terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm², cable cross section: 0.14...2.5 mm² AWG 26...AWG 12 solid

Screw type terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm², cable cross section: 0.14...2.5 mm² AWG 26...AWG 14 flexible without cable end

Screw type terminals, clamping capacity: 2 x 0.09...2 x 0.75 mm², cable cross section: 0.09...0.75 mm² AWG 28...AWG 20 flexible with cable end

Screw type terminals, clamping capacity: 2 x 0.2...2 x 2.5 mm², cable cross section: 0.2...2.5 mm² AWG 24...AWG 14 solid
Range of product
Advantys Telefast ABE7
Complementary
Terminal block type
Removable
Supply voltage limits
19...30 V DC (PLC end) conforming to IEC 61131-2
Isolation PLC/operative part
Yes
Protection type
Internal fuse of 1 A (5 x 20 mm), fast blow type at PLC end

Adjustable by external fuse, fast blow type at sensor end
Fixing mode
By clips on 35 mm symmetrical DIN rail

By screws on solid plate with fixing kit
Current per channel
0.012 A
Current state 1 guaranteed
>= 5 mA (sensor end)
Voltage state 1 guaranteed
>= 32 V (sensor end)
Maximum switching current
15 mA (PLC end)
Minimum switching current
1 mA (PLC end)
Response time
<= 20 ms from state 0 to 1

<= 20 ms from state 1 to 0
Switching frequency
<= 25 Hz duty cycle: 50 %
[Uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
2000 V
Installation category
II conforming to IEC 60664-1
Tightening torque
0.6 N.m (with flat Ø 3.5 mm)
Product weight
0.386 kg
Environment
Dielectric strength
2000 V 50/60 Hz conforming to IEC 60947-1
Product certifications
BV

CSA

DNV

GL

LROS (Lloyds register of shipping)

UL
Standards
IEC 61131-2 Type 1
IP degree of protection
IP2x conforming to IEC 60529
Resistance to incandescent wire
750 °C conforming to IEC 60695-2-11
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
2 gn (f = 10...150 Hz) conforming to IEC 60068-2-6
Resistance to electrostatic discharge
4 kV (contact) conforming to IEC 61000-4-2 level 3

8 kV (air) conforming to IEC 61000-4-2 level 3
Resistance to radiated fields
10 V/m (26000000...1000000000 Hz) conforming to IEC 61000-4-3 level 3
Resistance to fast transients
2 kV conforming to IEC 61000-4-4 level 3
Ambient air temperature for operation
-5...60 °C conforming to IEC 61131-2
Ambient air temperature for storage
-40...80 °C conforming to IEC 61131-2
Pollution degree
2 conforming to IEC 60664-1
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
End of Life Information
Product end of life instructions
Available
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:ABE7S16E2E0

   Frequently Asked Questions and Answers


  • What are the part numbers for the low cost Telefast sub-base for the m340 discrete input / output modules?

    Given below are the part numbers for the low cost sub-base: Legacy KB System (APS) Data: RESL198410 V1.0, Originally authored by TVe on 05/01/2009, Last Edited by TVe on 05/01/2009 Related ranges: Modicon M340, Advantys Telefast ABE7
    Read more

  • Reverse PID mode in Modicon M241/M251

    There is no input to select between direct/inverse direction at the PID function block from the Util library. The FB_PID function block (Toolbox library) is from Schneider and has additional features. With FB_PID function block from the Toolbox library in SoMachine to change the regulation direction user can use negative P-factor (i_rKp) The basic PID function must remain the same.
    Read more

  • Can we use 800 IOs with Modicon m580 Safety System without impact TUV certification

    There is no issue to use 800 series IOs without any impact on TÜV certificate on a M580 Safety configuration. As a general rule, all of Remote Distributed equipments on Ethernet allowed in M580 system could be considered as “non-interfering” for Safety M580 modules. However, of course, 800 series IOs data are not supposed to be used to perform safety functions.
    Read more

  • Video: Setting Persistent Variables with the Modicon M221 in SoMachine Basic

    The video demonstrates how to set up persistent variables and save them in the memory words of SoMachine Basic.  
    Read more

  • Video: Creating IODDTs for Modicon m340 I/O Modules via Unity Pro

     The attached video will illustrate creating 3 IODDTs for an M340 IO module: One for the Module health itself. One for Channel 0 using T_DIS_OUT_GEN which has two components. One for Channel 1 using T_DIS_OUT_STD which has 22 components.  
    Read more

Catalogue
  • file image Telefast pre-wiring system: Modicon ABE7 and Modicon ABE9 (pdf) download image`
Instruction sheet
  • file image ABE7S16E2... Sub-bases with soldered solid state inputs, plug-in terminal blocks (pdf) download image`
CAD
  • file image Premium automation platform - Telefast 2 - Sub-bases (dwf) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (dwg) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (dxf) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (wmf) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (dwf) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (dwg) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (dxf) download image`
  • file image Premium automation platform - Telefast 2 - Sub-bases (wmf) download image`
Declaration of conformity
  • file image NHA4191010.xx_DeclarationOfConformity_ABE7_ABR7_ABS7 (pdf) download image`
End of life manual
  • file image ABE7.... Modicon Telefast, pre-wired system, Product End-of-Life Instructions (pdf) download image`
  • file image ABE7.... Modicon Telefast, pre-wired system, Product End-of-Life Instructions (pdf) download image`
Marine certificate
  • file image DNV GL Type Approval Telefast (pdf) download image`

Dimensions Drawings

Dimensions



(1)
ABE7BV20 / ABE7BV20E


Mounting and Clearance

Mounting





Connections and Schema

HE10 16 Channels





Wiring Diagram



ABE7

U1, U2

S16E2B1 / E2B1E

24 VDC

S16E2E1 / E2E1E

48 VDC

S16E2E0 / E2E0E

48 VAC

S16E2F0 / E2F0E

115 VAC

S16E2M0 / E2M0E

230 VAC



Performance Curves

Curves for Determining Cable Type and Length According to the Current
16-channel Sub-base



L
Cable length
IT
Total current per sub base (A)
IA
Average current per channel (mA)
(1)
TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).
(2)
TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).
(3)
Cables with c.s.a. 0.13 mm2 (AWG 26).

The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.



© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech