A9D10810

iC60H - earth leakage circuit breaker - 1P + N - C curve - 10 A - 10 mA - 240 V
SKU
A9D10810
$265.69
Documents and Downloads
Instruction sheet
  • iC60N - RCBO instruction sheet (pdf)
CAD
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (dwf)
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (dwg)
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (dxf)
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (wmf)
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (pdf)
  • iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection (stp)
Certificate
  • CB Certificate SE-87253 for iC60N-H RCBO according to IEC 61009-1:2010 +A1 +A2 and IEC 61009-2-2:1991 (pdf)
  • CB Test Certificate (pdf)
  • Certificate of Approval (pdf)
Declaration of conformity
  • EU Declaration FD16040504B for iC60N-H RCBO (pdf)
End of life manual
  • iC60 RCBO - EoLi (pdf)
Product environmental
  • iC 60 RCBO - PEP (pdf)
REACh Declaration
  • iC60H - earth leakage circuit breaker - 1P + N - C curve - 10 A - 10 mA - 240 V (pdf)
RoHs Declaration
  • iC60H - earth leakage circuit breaker - 1P + N - C curve - 10 A - 10 mA - 240 V (pdf)
Description
iC60H - earth leakage circuit breaker - 1P + N - C curve - 10 A - 10 mA - 240 V
More Information
More Information
poles description1P + N
Current Rating10 A
Interrupt Rating10000 A
earth-leakage sensitivity10 mA
Reviews
Write Your Own Review
Characterstics
Main
Circuit breaker application
Distribution
Range
Acti 9
Product name
Acti 9 iC60 RCBO
Product or component type
Residual current breaker with overcurrent protection (RCBO)
Device short name
IC60H RCBO
Poles description
1P + N
[In] rated current
10 A at 50 °C
Earthing system
TN
Curve code
C
Earth-leakage sensitivity
10 mA
Breaking capacity
Icn : 10000 A - 240 V - AC at 50/60 Hz
Complementary
Neutral position
Left
Number of protected poles
1
Device location in system
Outgoer
Network type
AC
Network frequency
50 Hz
[Ue] rated operational voltage
Ue: 240 V - AC at 50/60 Hz
Trip unit technology
Thermal-magnetic
Residual current tripping technology
Voltage dependent
Earth-leakage protection time delay
Instantaneous
Earth-leakage protection class
Type A
[Icw] rated short-time withstand current
Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity
Ics: 7500 A - 240 V - AC at 50/60 Hz
Limitation class
3
[Ui] rated insulation voltage
Ui: 400 V - AC at 50/60 Hz
[Uimp] rated impulse withstand voltage
Uimp: 4 kV
Suitability for isolation
Yes
Contact position indicator
Yes
Control type
Toggle
Local signalling
ON/OFF indication
Mounting mode
Clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
NO
9 mm pitches
2
Height
110 mm
Width
18 mm
Depth
77.5 mm
Product weight
205 g
Colour
White
Mechanical durability
20000 cycles
Electrical durability
5000 cycles
Provision for padlocking
Padlockable with padlock Ø 4 mm
Locking options description
ON/OFF locking facilities
Connections - terminals
Screw clamp terminal connection on top - 1...25 mm² - rigid - without cable end

Screw clamp terminal connection on top - 1...16 mm² - flexible

Screw clamp terminal connection on bottom - 1...16 mm² - rigid - without cable end

Screw clamp terminal connection on bottom - 1...10 mm² - flexible
Wire stripping length
13 mm on bottom of power circuit

14 mm on top of power circuit
Tightening torque
3.5 N.m on top of power circuit

2 N.m on bottom of power circuit
Earth-leakage protection
Integrated
Environment
Standards
IEC 61009-1

BS EN 61009-1

IEC 61009-2-2

AS/NZS 61009.1
IP degree of protection
IP20
Tropicalisation
2
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-15...60 °C
Ambient air temperature for storage
-40...85 °C
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Go to CaP for more details
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information