33467
circuit breaker Compact NS800H - Micrologic 2.0 - 800 A - 3 poles 3t
SKU
33467
$5,409.93
User guide
Catalogue
Instruction sheet
CAD
Certificate
End of life manual
circuit breaker Compact NS800H - Micrologic 2.0 - 800 A - 3 poles 3t
poles description | 3P |
---|---|
Current Rating | 800 A |
breaking capacity code | H |
trip unit name | Micrologic 2.0 |
control type | Rotary handle, Toggle |
Write Your Own Review
Main
- Range
- Compact
- Range of product
- NS630b...1600
- Product or component type
- Circuit breaker
- Device short name
- Compact NS800H
- Device application
- Distribution
- Poles description
- 3P
- Protected poles description
- 3t
- Network type
- AC
- Breaking capacity code
- H
- Suitability for isolation
- Yes conforming to IEC 60947-2
- Utilisation category
- Category B
- Trip unit name
- Micrologic 2.0
- Trip unit technology
- Electronic
- Trip unit rating
- 800 A ( 50 °C )
Complementary
- Network frequency
- 50/60 Hz
- Control type
- Rotary handle
Toggle - Mounting mode
- Fixed
- Mounting support
- Backplate
- Upside connection
- Front
- Downside connection
- Front
- [In] rated current
- 800 A ( 50 °C )
- [Ui] rated insulation voltage
- 800 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage
- 8 kV conforming to IEC 60947-2
- [Ue] rated operational voltage
- 690 V AC 50/60 Hz conforming to IEC 60947-2
- Circuit breaker CT rating
- 800 A
- Breaking capacity
- 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 - [Ics] rated service breaking capacity
- Ics 30 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Ics 40 kA 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2 - Auxiliary contact composition
- 1 NO/NC
- Mechanical durability
- 10000 cycles
- Electrical durability
- 2000 cycles IEC 60947-2 690 V In AC 50/60 Hz
4000 cycles IEC 60947-2 690 V In/2 AC 50/60 Hz
5000 cycles IEC 60947-2 440 V In AC 50/60 Hz
6000 cycles IEC 60947-2 440 V In/2 AC 50/60 Hz - Local signalling
- Positive contact indication
- [Icw] rated short-time withstand current
- 19.2 kA
- Trip unit protection functions
- LI
- Protection type
- Instantaneous short-circuit protection
Overload protection (long time) - Long time pick-up adjustment type Ir
- Adjustable
- Long time pick-up adjustment range
- 0.4...1 x In
- Long time delay adjustment type
- Adjustable 9 settings
- [tr] long-time delay adjustment range
- 0.5...24 s 6 x Ir
0.7...16.6 s 7.2 x Ir
12.5...600 s 1.5 x Ir - Thermal memory
- 20 mn
- Instantaneous pick-up adjustment type Ii
- Adjustable
- Instantaneous pick-up adjustment range
- 1.5...10 x Ir
- Integral instant protection
- 40 kA
- Height
- 327 mm
- Width
- 210 mm
- Depth
- 147 mm
Environment
- Standards
- IEC 60947-2
- Product certifications
- ASEFA
ASTA - Power losses
- 15 W
- IP degree of protection
- IP40 conforming to IEC 60529
- IK degree of protection
- IK07 conforming to EN 50102
- Pollution degree
- 3 conforming to IEC 60947
- Ambient air temperature for operation
- -25...70 °C
- Ambient air temperature for storage
- -50...85 °C
Offer Sustainability
- Sustainable offer status
- Green Premium product
- RoHS (date code: YYWW)
- Schneider Electric declaration of conformity
- REACh
- Reference not containing SVHC above the threshold
- Product environmental profile
- End of Life Information
- Product end of life instructions
- Need no specific recycling operations
Contractual warranty
- Warranty period
- 18 months