28902

$199.54
Generally ships in 1 to 2 days
SKU
28902

switch-disconnector Compact INS63 - 3 poles - 63 A

Main
Range
Compact
Product name
Compact INS
Product or component type
Switch disconnector
Poles description
3P
Network type
AC

DC
Network frequency
50/60 Hz
[Ie] rated operational current
63 A AC 50/60 Hz for 220/240 V in category AC-22A

63 A AC 50/60 Hz for 380/415 V in category AC-22A

63 A AC 50/60 Hz for 440/480 V in category AC-22A

63 A AC 50/60 Hz for 500 V in category AC-22A

40 A AC 50/60 Hz for 500 V in category AC-23A

63 A AC 50/60 Hz for 220/240 V in category AC-23A

63 A AC 50/60 Hz for 380/415 V in category AC-23A

63 A AC 50/60 Hz for 440/480 V in category AC-23A

63 A DC for 125 V in category DC-22A (2 poles in series)

63 A DC for 125 V in category DC-23A (2 poles in series)
[Ui] rated insulation voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
63 A ( 60 °C )
[Icm] rated short-circuit making capacity
15 kA 500 V AC 50/60 Hz switch-disconnector alone

75 kA 500 V AC 50/60 Hz with upstream protection circuit breaker
[Ue] rated operational voltage
125 V DC

500 V AC 50/60 Hz
Suitability for isolation
Yes
Contact position indicator
Yes
Visible break
No
Pollution degree
3
Complementary
Control type
Rotary handle
Handle colour
Black
Mounting mode
Fixed
Mounting support
DIN rail

Plate
Upside connection
Front
Downside connection
Front
Cable cross section
1.5...50 mm²
Maximum power
15 kW AC 50/60 Hz for 220/240 V in category AC-23

22 kW AC 50/60 Hz for 500/525 V in category AC-23

30 kW AC 50/60 Hz for 380/415 V in category AC-23

30 kW AC 50/60 Hz for 440 V in category AC-23
Rated duty
Uninterrupted
Intermittent duty class
Class 120 - 60 %
Enclosure dimensions for Ithe
190 mm x 115 mm x 55 mm
[Icw] rated short-time withstand current
0.067 kA ( 20 s ) conforming to IEC 60947-3

1.73 kA ( 3 s ) conforming to IEC 60947-3

3 kA ( 1 s ) conforming to IEC 60947-3

5.5 kA ( 30 s ) conforming to IEC 60947-3
Mechanical durability
20000 cycles
Electrical durability
1500 cycles for 220/240 V AC 50/60 Hz in category AC-22A

1500 cycles for 380/415 V AC 50/60 Hz in category AC-22A

1500 cycles for 440 V AC 50/60 Hz in category AC-22A

1500 cycles for 500 V AC 50/60 Hz in category AC-22A

1500 cycles for 220/240 V AC 50/60 Hz in category AC-23A

1500 cycles for 380/415 V AC 50/60 Hz in category AC-23A

1500 cycles for 440 V AC 50/60 Hz in category AC-23A

1500 cycles for 500 V AC 50/60 Hz in category AC-23A

1500 cycles for 250 V DC in category DC-22A (2 poles in series)

1500 cycles for 250 V DC in category DC-23A (2 poles in series)
Connection pitch
18 mm
Height
85 mm
Width
90 mm
Depth
62.5 mm
Product weight
0.5 kg
Environment
Standards
IEC 60947-1

IEC 60947-3
Product certifications
CCC

KEMA-KEUR
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to EN 50102
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-50...85 °C
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:28902

   Frequently Asked Questions and Answers


  • Are the individual enclosures for INS/INV switches equipped with a locking mechanism?

    The heavy-duty metal individual enclosures for Compact INS/INV switches are equipped from the factory with a triangle key lock and key. The lock can afterwards be changed by the user with one of the types from the attached illustration.   spare lock.JPG
    Read more

  • ETSNZ - What control voltages are available for Compact/Masterpact automatic source changeovers?

    In New Zealand we only offer 400V control for our automatic source changeovers.
    Read more

  • What is the Modbus port pinout for the Compact PC-E984-241 PLC?

    Please see attached Modbus port pinout. ASW952012.bmp  
    Read more

  • How do I add support to Concept for the Compact BVIC and BVRC I/O modules?

    A Modconnect .MDC file must be loaded through Concept's ModConnect Tool to add support for these modules. Go to IANET or the Schneider Services (Eclipse) websites and choose Software - Concept - Resolutions to download the necessary files. Follow the installation instructions. Legacy KB System (APS) Data: RESL163988 V1.0, Originally authored by on , Last Edited by on Related ranges: Concept
    Read more

  • How can I lock the direct rotary handle on a Compact ns400 / ns630 circuit-breaker?.

    The direct rotary handle can either be locked with padlocks or a keylock. Locking with Padlocks: Up to three padlocks can be fitted. The shackle diameter must be between 5 to 8mm. Locking with a keylock: Install: a keylock adaptor (without lock), part number 32604, and either a Ronis lock, part number 41940 or a Profalux lock 42888 The locks have random key numbers and come complete with two keys.
    Read more

Catalogue
  • file image COMPACT NSX, COMPACT INS INV and MASTERPACT NW - DC- DC PV catalogue (pdf) download image`
Instruction sheet
  • file image Compact INS40–160 - Switch disconnector (pdf) download image`
CAD
  • file image Auxiliary contactEarly-make contact CAF (dwf) download image`
  • file image Auxiliary contactEarly-make contact CAF (dwg) download image`
  • file image Auxiliary contactEarly-make contact CAF (dxf) download image`
  • file image Auxiliary contactEarly-make contact CAF (wmf) download image`
  • file image switchdisconnec to r Interpact (zip) download image`
  • file image switchdisconnec to r Interpact (stp) download image`
  • file image Compact INS40 to INS80 3P; Switch Disconnector (pdf) download image`
  • file image Compact INS40 to INS80 3P; Switch Disconnector (stp) download image`
Product environmental
  • file image PEP Interpact INS40 to INS80 (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech