XY2AU1

$850.08
Generally ships in 1 to 2 days
SKU
XY2AU1

enabling switch - 2 NO + 1 NC - double insulated

Main
Range of product
Preventa XY2
Product or component type
Enabling switch
Component name
XY2AU
Enclosure type
Double insulated
Complementary
Contacts type and composition
2 NO + 1 NC
Operator position information
3 positions
Enclosure material
PA66
Connections - terminals
Terminal block : 1 x 0.34...1 x 1.5 mm²
Mechanical durability
1000000 cycles
Cable entry
1 entry, 7...13 mm
Contact code designation
C300 with AC-15 utilisation category at 125 V, 0.75 A AC current conforming to IEC 60947-5-1 appendix A

C300 with AC-15 utilisation category at 250 V, 1.5 A AC current conforming to IEC 60947-5-1 appendix A

R300 with DC-13 utilisation category at 125 V, 0.22 A DC current conforming to IEC 60947-5-1 appendix A

R300 with DC-13 utilisation category at 250 V, 0.1 A DC current conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
5 A
[Ui] rated insulation voltage
250 V inside (degree of pollution: 2) conforming to IEC 60947-1

250 V outside (degree of pollution: 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
2.5 kV conforming to EN 60947-1
Positive opening
With conforming to IEC 60947-5-1 appendix K
Contact operation
Slow-break
Operating force
12 N

50 N
Short-circuit protection
4 A fuse protection by cartridge fuse type gG
Product weight
0.31 kg
Environment
Standards
CULus 508

EN/IEC 60947-1

EN/IEC 60947-5-1

CSA C22.2 No 14
Protective treatment
TC
Ambient air temperature for operation
-10...60 °C
Ambient air temperature for storage
-40...70 °C
Vibration resistance
6 gn (f = 5...55 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class II conforming to EN/IEC 61140
IP degree of protection
IP66 conforming to IEC 60529
IK degree of protection
IK06 conforming to EN 50102
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XY2AU1

   Frequently Asked Questions and Answers


  • CAD file for XY2SB.

    Goals and Symptoms CAD file for XY2SB. Causes and Fixes Select attachment Legacy KB System (APS) Data: RESL203137 V1.0, Originally authored by LaBe on 08/19/2010, Last Edited by LaBe on 08/19/2010 Related ranges: Preventa XY2 SB
    Read more

  • What is the RAL-color of a XY2SB714 ?

    Goals and Symptoms What is the RAL-color of a XY2SB714 ? Facts and Changes XY2SB714 XY2SB RAL Causes and Fixes The RAL is orange 2008. Legacy KB System (APS) Data: RESL171519 V2.0, Originally authored by ViRe on 07/24/2007, Last Edited by JeLe on 07/26/2013 Related ranges: Preventa XY2 SB
    Read more

  • Do we do any 110 volt AC safety module in XPSAC series?

    We do an 115 Volt AC module with part no XPSAC3421. Please refer the below link for more details. https://www.schneider-electric.com.au/en/product-range-selector/626-preventa-xps/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecat%2Fbrowse.do%3Fconf%3Dnull%26el_typ%3Dproduct%26range_id%3D626%26prd_id%3DXPSAC3421%26scp_id%3DAU_en
    Read more

  • What are the details for the heat dissipation for the Preventa XPSAC and XPSECME safety modules?

    Criterion for relay contacts to be worn out electrically is contact resistance is >= 100 mOhm. Given two contacts with 100 mOhm each in line and the thermal sum current of 10,5 A distributed over 3 channels in case of XPSAC gives a maximum heat dissipation of 7,35 W in the output channels of the XPSAC. Given two contacts with 100 mOhm each in line and the thermal sum current of 12 A distributed over 6 channels in case of XPSECME gives a maximum heat dissipation 4,8 W in the output channels of the XPSECME...
    Read more

  • Preventa XY2C - Dimensions of the xy2cz402 turnbuckle

    Find attached dimensions of the XY2CZ402 turnbuckle. XY2CZ402 dimensions.pdf
    Read more

Catalogue
  • file image Enabling movement -Enabling switches for safety circuits XY2AU (pdf) download image`
Instruction sheet
  • file image XY2AU1 / XY2AU2 Enabling switches (pdf) download image`
Certificate
  • file image XY2AU Enabling grip switch (html) download image`
  • file image XY2AU Enabling grip switch (html) download image`
Declaration of conformity
  • file image XY2AU Enabling switch (pdf) download image`

Dimensions Drawings

Dimensions





Connections and Schema

Wiring Diagram Example
With XPSVC Safety Module



ESC
external start conditions
(1)
2 solid state outputs
(2)
2 safety outputs
(3)
supply A1/A2
(4)
fault
(5)
logic
(6)
to PLC



contact closed

contact open

N/C contact with positive opening operation



© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech