limit switch XCKL - metal end plunger - 1NC+1NO - snap action - Cable gland

Main
Range of product
OsiSense XC
Series name
Standard format
Product or component type
Limit switch
Device short name
XCKL
Body type
Fixed
Head type
Plunger head
Material
Metal
Body material
Zamak
Fixing mode
By the body
Movement of operating head
Linear
Type of operator
Spring return plunger metal
Type of approach
Vertical approach 1 direction
Cable entry
1 metal cable gland entry, cable outer diameter: 6...13.5 mm
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Snap action
Complementary
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation form
Zb
Number of steps
1
Positive opening
With
Positive opening minimum force
45 N
Minimum force for tripping
15 N
Minimum actuation speed
0.01 m/min
Maximum actuation speed
0.5 m/s
Repeat accuracy
0.05 mm on the tripping points with 1 million operating cycles
Contact code designation
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A AC
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14

500 V degree of pollution 3 conforming to IEC 60947-1

300 V conforming to UL 508
Resistance across terminals
<= 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664

6 kV conforming to IEC 60947-1
Short-circuit protection
10 A by gG cartridge fuse
Electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
20000000 cycles
Width
52 mm
Height
72 mm
Depth
30 mm
Product weight
0.255 kg
Terminals description ISO n°1
(13-14)NO

(21-22)NC
Switch actuation
On end
Environment
Shock resistance
50 gn (duration = 11 ms) conforming to EN/IEC 60068-2-27
Vibration resistance
25 gn (f = 10...500 Hz) conforming to EN/IEC 60068-2-6
IP degree of protection
IP66 conforming to EN/IEC 60529
IK degree of protection
IK05 conforming to EN 50102
Electrical shock protection class
Class I conforming to IEC 61140

Class I conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Protective treatment
TC
Product certifications
CSA

UL
Standards
EN 60204-1

EN 60947-5-1

IEC 60204-1

IEC 60947-5-1

UL 508

CSA C22.2 No 14
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XCKL110

   Frequently Asked Questions and Answers


  • Video: OsiSense XC standard - How to read the complete XCMD switch references

    Goals and Symptoms OsiSense XC standard - How to read the complete XCMD switch references Facts and Changes XCMD universal limit switch How to read a complete switch reference Causes and Fixes Attached document showing how to read a complete switch reference from the sub-assemblies indicated into the \'Detection for OsiSense solutions\' catalogue, in the XCMD limit switch series. On the complete XCMN switch series for OEM, the switch reference is indicated directly on the housing. XCM_Lim...
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKJ limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKJ limit switches produced in France, valid up to January 2020. CCC 2006010305196237_France_XCKJ,ZCKJ,ZCKZ_Valid up to january 2020 (1).pdf
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKS limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKS limit switches produced in France, valid up to January 2020. CCC 2006010305196240_France_XCKS,XCKSD,ZCKS,ZCKSD_Valid up to january 2020.pdf
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKM limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKM and XCKMD limit switches produced in France, valid up to January 2020. CCC 2006010305196231_France_XCKM,XCKMD,ZCKM,ZCKMD_Valid up to january 2020.pdf
    Read more

  • Osisense XC standard - up-to-date CCC certificate for the XCMD limit switches (origin Indonesia)

    Find attached the up-to-date CCC certificate for the XCMD and XCMN limit switches produced in Indonesia, valid up to December 2019. CCC 2003010305059244 Indonesia XCMN,XCMD,XCSM,ZCMD Valid up to dec 2019 V2 2016.pdf
    Read more

Catalogue
  • file image Limit switches OsiSense XC Standard (pdf) download image`
CAD
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dwf) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dwg) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dxf) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (wmf) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dwf) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dwg) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (dxf) download image`
  • file image metalcomplete switches with 1 cable entry incorporating cable glandmetal end plunger (wmf) download image`
Certificate
  • file image XCKB..., XCKL/M/ML/MR..., ZCKL/M/ML..., XCKP/T..., XCKS... and ZCKS/SD... limit switches - CSA certificate of compliance (pdf) download image`
  • file image XC... limit switches - UL certification record (html) download image`
Declaration of conformity
  • file image XC... limit switches - EU declaration of conformity (pdf) download image`
Marine certificate
  • file image XCKJ/L/M... limit switches - BV type approval certificate (pdf) download image`
Product environmental
  • file image XCKJ10541 Metal Limit Switch, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image limit switch XCKL - metal end plunger - 1NC+1NO - snap action - Cable gland (pdf) download image`
RoHs Declaration
  • file image limit switch XCKL - metal end plunger - 1NC+1NO - snap action - Cable gland (pdf) download image`

Dimensions Drawings

Dimensions



(1)
Pg 13.5 cable gland
Ø :
2 elongated holes Ø 5.2 x 6.2


Mounting and Clearance

Mounting with Cable Entry
Position of Cable Gland



(1)
Recommended
(2)
To be avoided


Connections and Schema

Wiring Diagram
2-pole NC + NO Snap Action





Technical Description

Characteristics of Actuation
Switch Actuation on End





Functionnal Diagram



(P)
Positive opening point
(1)
NC contact with positive opening operation
(2)
Closed
(3)
Open
(4)
Tripping
(5)
Resetting