XCKD2521G11

$177.41
Special Order-Generally ships in 14 to 21 Business Days
SKU
XCKD2521G11

limit switch XCKD - th.plastic roller lever plung. Hor - 1NC+1NO - slow - Pg11

Main
Range of product
OsiSense XC
Series name
Standard format
Product or component type
Limit switch
Device short name
XCKD
Sensor design
Compact form E conforming to CENELEC EN 50047
Body type
Fixed
Head type
Plunger head
Material
Metal
Body material
Zamak
Head material
Zamak
Fixing mode
By the body
Movement of operating head
Linear
Type of operator
Spring return roller lever plunger thermoplastic
Type of approach
Lateral approach 1 direction
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, break before make
Complementary
Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Cable entry
1 entry tapped for Pg 11 cable gland
Contacts insulation form
Zb
Positive opening
With
Positive opening minimum force
18 N
Minimum force for tripping
6 N
Maximum actuation speed
1 m/s
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Contact code designation
A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN 60947-5-1

A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to IEC 60947-5-1 appendix A

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN 60947-5-1

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14

500 V degree of pollution 3 conforming to IEC 60947-1

300 V conforming to UL 508
Resistance across terminals
<= 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664

6 kV conforming to IEC 60947-1
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
5000000 cycles, DC-13, 120 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 24 V, 13 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 48 V, 9 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
15000000 cycles
Width
31 mm
Height
65 mm
Depth
30 mm
Product weight
0.195 kg
Terminals description ISO n°1
(13-14)NO

(21-22)NC
Environment
Shock resistance
50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
IK degree of protection
IK06 conforming to EN 50102
Electrical shock protection class
Class I conforming to IEC 61140

Class I conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Protective treatment
TC
Product certifications
CCC

CSA

UL
Standards
EN 60204-1

EN 60947-5-1

IEC 60204-1

IEC 60947-5-1

UL 508

CSA C22.2 No 14
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XCKD2521G11

   Frequently Asked Questions and Answers


CAD
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dwf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dwg) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dxf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (wmf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dwf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dwg) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (dxf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, thermoplastic roller lever plunger horizontal actuation in 1 direction (wmf) download image`
Certificate
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches (made in Indonesia) - Certificate for China compulsory product certification (pdf) download image`
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches (made in France) - Certificate for China compulsory product certification (pdf) download image`
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches - CSA certificate of compliance (pdf) download image`
  • file image XC... limit switches - UL certification record (html) download image`
Declaration of conformity
  • file image XC... limit switches - EU declaration of conformity (pdf) download image`
Product environmental
  • file image XCKJ10541 Metal Limit Switch, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image limit switch XCKD - th.plastic roller lever plung. Hor - 1NC+1NO - slow - Pg11 (pdf) download image`
RoHs Declaration
  • file image limit switch XCKD - th.plastic roller lever plung. Hor - 1NC+1NO - slow - Pg11 (pdf) download image`

Dimensions Drawings

Dimensions





(1)
Tapped entry for Pg 11 cable gland
(2)
2 elongated holes Ø 4.3 x 6.3 mm on 22 mm centres, 2 holes Ø 4.3 on 20 mm centres.
(3)
2 x Ø 3 holes for support studs, depth 4 mm.


Mounting and Clearance

Mounting with Cable Entry
Position of Cable Gland



(1)
Recommended
(2)
To be avoided


Setting-up
Plunger or Multi-directional Heads





Connections and Schema

Wiring Diagram
2-pole NC + NO Break before Make, Slow Break





Technical Description

Characteristics of Actuation
Switch Actuation by 30° Cam





Functionnal Diagram



(P)
Positive opening point
(A)
Cam displacement
(1)
NC contact with positive opening operation
(2)
Closed
(3)
Open


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech