XCKD2149G11

$258.26
Special Order-Generally ships in 14 to 21 Business Days
SKU
XCKD2149G11

limit switch XCKD - plastic roller lever Ø50 var.length - 1NC+1NO - snap - Pg11

Main
Range of product
OsiSense XC
Series name
Standard format
Product or component type
Limit switch
Device short name
XCKD
Sensor design
Compact
Body type
Fixed
Range of product
OsiSense XC
Head type
Rotary head
Series name
Standard format
Material
Metal
Product or component type
Limit switch
Body material
Zamak
Device short name
XCKD
Head material
Zamak
Sensor design
Compact
Fixing mode
By the body
Body type
Fixed
Movement of operating head
Rotary
Head type
Rotary head
Type of operator
Spring return roller lever thermoplastic (variable length, roller diameter 50 mm)
Material
Metal
Type of approach
Lateral approach 2 directions
Body material
Zamak
Number of poles
2
Head material
Zamak
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the body
Contact operation
Snap action
Movement of operating head
Rotary
Type of operator
Spring return roller lever thermoplastic (variable length, roller diameter 50 mm)
Type of approach
Lateral approach 2 directions
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Snap action
Complementary
Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Cable entry
1 entry tapped for Pg 11 cable gland
Contacts insulation form
Zb
Positive opening
With
Minimum torque for tripping
0.1 N.m
Switch actuation
By 30° cam
Maximum actuation speed
1.5 m/s
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Cable entry
1 entry tapped for Pg 11 cable gland
Contact code designation
A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN 60947-5-1

A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to IEC 60947-5-1 appendix A

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN 60947-5-1

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A
Contacts insulation form
Zb
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14

500 V degree of pollution 3 conforming to IEC 60947-1

300 V conforming to UL 508
Positive opening
With
Resistance across terminals
<= 25 MOhm conforming to IEC 60255-7 category 3
Minimum torque for tripping
0.1 N.m
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664

6 kV conforming to IEC 60947-1
Maximum actuation speed
1.5 m/s
Short-circuit protection
10 A cartridge fuse gG
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Contact code designation
A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN 60947-5-1

A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to IEC 60947-5-1 appendix A

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN 60947-5-1

Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A
Mechanical durability
10000000 cycles
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14

500 V degree of pollution 3 conforming to IEC 60947-1

300 V conforming to UL 508
Width
31 mm
Resistance across terminals
<= 25 MOhm conforming to IEC 60255-7 category 3
Height
65 mm
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664

6 kV conforming to IEC 60947-1
Depth
30 mm
Short-circuit protection
10 A cartridge fuse gG
Product weight
0.245 kg
Electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

5000000 cycles, DC-13, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Terminals description ISO n°1
(13-14)NO

(21-22)NC
Mechanical durability
10000000 cycles
Width
31 mm
Height
65 mm
Depth
30 mm
Product weight
0.245 kg
Terminals description ISO n°1
(13-14)NO

(21-22)NC
Environment
Shock resistance
50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
IK degree of protection
IK06 conforming to EN 50102
Electrical shock protection class
Class I conforming to IEC 61140

Class I conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Shock resistance
50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Protective treatment
TC
Vibration resistance
25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Product certifications
CCC

CSA

UL
IK degree of protection
IK06 conforming to EN 50102
Standards
EN 60204-1

EN 60947-5-1

IEC 60204-1

IEC 60947-5-1

UL 508

CSA C22.2 No 14
Electrical shock protection class
Class I conforming to IEC 61140

Class I conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Protective treatment
TC
Product certifications
CCC

CSA

UL
Standards
EN 60204-1

EN 60947-5-1

IEC 60204-1

IEC 60947-5-1

UL 508

CSA C22.2 No 14
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product end of life instructions
Need no specific recycling operations
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Warranty period
18 months
Write Your Own Review
You're reviewing:XCKD2149G11

   Frequently Asked Questions and Answers


  • Video: OsiSense XC standard - How to read the complete XCMD switch references

    Goals and Symptoms OsiSense XC standard - How to read the complete XCMD switch references Facts and Changes XCMD universal limit switch How to read a complete switch reference Causes and Fixes Attached document showing how to read a complete switch reference from the sub-assemblies indicated into the \'Detection for OsiSense solutions\' catalogue, in the XCMD limit switch series. On the complete XCMN switch series for OEM, the switch reference is indicated directly on the housing. XCM_Lim...
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKJ limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKJ limit switches produced in France, valid up to January 2020. CCC 2006010305196237_France_XCKJ,ZCKJ,ZCKZ_Valid up to january 2020 (1).pdf
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKS limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKS limit switches produced in France, valid up to January 2020. CCC 2006010305196240_France_XCKS,XCKSD,ZCKS,ZCKSD_Valid up to january 2020.pdf
    Read more

  • Osisense XC standard - Up-to-date CCC certificate for the XCKM limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCKM and XCKMD limit switches produced in France, valid up to January 2020. CCC 2006010305196231_France_XCKM,XCKMD,ZCKM,ZCKMD_Valid up to january 2020.pdf
    Read more

  • Osisense XC standard - up-to-date CCC certificate for the XCMD limit switches (origin Indonesia)

    Find attached the up-to-date CCC certificate for the XCMD and XCMN limit switches produced in Indonesia, valid up to December 2019. CCC 2003010305059244 Indonesia XCMN,XCMD,XCSM,ZCMD Valid up to dec 2019 V2 2016.pdf
    Read more

CAD
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dwf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dwg) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dxf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (wmf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dwf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dwg) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (dxf) download image`
  • file image Plastic or metal XCK P or XCK D, cable entry ISO 16/PG 11, variable length thermoplastic roller lever plunger dia. 50 mm (wmf) download image`
Certificate
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches (made in Indonesia) - Certificate for China compulsory product certification (pdf) download image`
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches (made in France) - Certificate for China compulsory product certification (pdf) download image`
  • file image XCKD/P/T..., ZCD/P/T..., XCDR..., XCPR..., XCTR... limit switches and XCSD/P... safety switches - CSA certificate of compliance (pdf) download image`
  • file image XC... limit switches - UL certification record (html) download image`
Declaration of conformity
  • file image XC... limit switches - EU declaration of conformity (pdf) download image`
Product environmental
  • file image XCKJ10541 Metal Limit Switch, Product Environmental Profile (pdf) download image`

Dimensions Drawings

Dimensions





(1)
Tapped entry for Pg 11 cable gland
(2)
2 elongated holes Ø 4.3 x 6.3 mm on 22 mm centres, 2 holes Ø 4.3 on 20 mm centres.
(3)
2 x Ø 3 holes for support studs, depth 4 mm.


Mounting and Clearance

Mounting with Cable Entry
Position of Cable Gland



(1)
Recommended
(2)
To be avoided


Mounting with Rotary Heads and Levers
Type of Cam



(1)
Recommended
(2)
To be avoided


Setting-up with Head ZCE01 and ZCE09



(1)
Tightening torque (Min : 1) (Max : 1.5)
(2)
Tightening torque (Min : 0.8) (Max : 1.2)


Connections and Schema

Wiring Diagram
2-pole NC + NO Snap Action





Technical Description

Characteristics of Actuation
Switch Actuation by 30° Cam





Functionnal Diagram



(1)
Closed
(2)
Open
(4)
Tripping
(5)
Resetting


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech