XC1AC116

$644.03
Special Order-Generally ships in 14 to 21 Business Days
SKU
XC1AC116

limit switch XC1AC - roller lever - 1C/O

Main
Range of product
OsiSense XC
Series name
Special format
Product or component type
Limit switch
Product specific application
Materials handling
Device short name
XC1AC
Sensor design
-
Body type
Fixed
Head type
Plunger head
Material
Metal
Fixing mode
By the body
Movement of operating head
Linear
Type of operator
Spring return roller lever metal -
Switch actuation
By 30° cam
Type of approach
Lateral approach 2 directions
Electrical connection
Screw-clamp terminals, 1 x 0.5...1 x 2.5 mm²
Cable entry
3 entries tapped for Pg 13.5 cable gland, cable outer diameter: 9...12 mm
Number of poles
1
Contacts type and composition
1 C/O
Contact operation
Slow-break
Number of steps
1
Positive opening
Without
Minimum force for tripping
23 N
Complementary
Terminals description ISO n°1
(11-12)NC

(13-14)NO
Contacts insulation form
Za
Maximum actuation speed
0.5 m/s
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
600 V AC CSA C22.2 No 14

600 V DC CSA C22.2 No 14

500 V AC IEC 60947-5-1

500 V AC NF C 20-040

600 V DC IEC 60947-5-1

600 V DC NF C 20-040
Resistance across terminals
<= 8 mOhm
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
1000000 cycles AC-15, 110 V 900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

1000000 cycles AC-15, 230 V 1900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

1000000 cycles AC-15, 48 V 450 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

1000000 cycles DC-13, 110 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type

1000000 cycles DC-13, 230 V 95 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type

1000000 cycles DC-13, 48 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type

3000000 cycles AC-15, 110 V 350 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

3000000 cycles AC-15, 230 V 430 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

3000000 cycles AC-15, 48 V 170 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type

3000000 cycles DC-13, 110 V 40 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type

3000000 cycles DC-13, 230 V 33 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type

3000000 cycles DC-13, 48 V 35 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type
Mechanical durability
10000000 cycles
Width
77 mm
Height
130 mm
Depth
44 mm
Product weight
0.53 kg
Environment
Shock resistance
95 gn 11 ms IEC 60068-2-27
Vibration resistance
9 gn 10...500 Hz IEC 60068-2-6
IP degree of protection
IP65 IEC 60529

IP65 NF C 20-010
Electrical shock protection class
Class I conforming to IEC 61140

Class I conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Protective treatment
TC
Operating position
Any position
Product certifications
CSA
Standards
EN 60947-5-1

IEC 60337-1

IEC 60947-5-1

VDE 0660-200

CSA C22.2 No 14
Offer Sustainability
RoHS (date code: YYWW)
Will not be compliant
REACh
Reference not containing SVHC above the threshold
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XC1AC116

   Frequently Asked Questions and Answers


  • Osisense XC special_XCRT115 XCRT215 Mechanical stop of the roller arm_How to adjust

    Please find attached a document showing the mechanical stop of the roller arm and how to adjust. Such function is not documented into the catalogue pages. XCRT115 XCRT215_Mechanical stop of the roller arm.pdf
    Read more

  • Osisense XC special - Up-to-date CCC certificate for the XCR limit switches (origin France)

    Find attached the up-to-date CCC certificate for the XCR limit switches produced in France, valid up to January 2020. CCC 2008010305268106_France_XCR valid up to january 2020.pdf
    Read more

  • What is the ZC4CC reference? How to order?

    ZC4CC is not a commercial reference, but the marking on the contact ZC4CC2, sold in spare parts for the obsolete XR2PA* safety screw limit switch for mechanical press. See attached picture. ZC4CC2 is still available to order in 2015. It is a slow break contact type. ZC4CC picture.jpg
    Read more

  • Osisense XC_Obsolete XCKP9279 switch with reset : how to replace it

    The obsolete XCKP9279 switch was a roller lever plunger switch with 2 NC contacts, snap action block, for vertical direction (special model), having reset function, plastic casing in black colour. The equivalent switch in the Osisense XC offer is the XCPR2927G13 commercial reference with 2NC contacts positive opening, snap action. Attached corresponding datasheet downloaded from \'tesensors.com\' site. OsiSense XC_XCPR2927G13 datasheet.pdf
    Read more

  • Osisense XC - Datasheet of the adapted limit switch xcmn2115t1l0

    Please find attached the datasheet of the adapted limit switch XCMN2115T1L0, using a special cable halogen free for railway equipments, complying to EN 50306 and EN 45545 standards. Cable lenght = 1m. This reference is available to order without any restriction. It is not in stock, it is produced at order reception by the assembly plant. A second similar reference exists with 50cm cable lenght only : XCMN2115T05L0. Adapted switch XCMN2115T1L0 datasheet.pdf
    Read more

Catalogue
  • file image Limit switches OsiSense XC Special (pdf) download image`
Instruction sheet
  • file image XC1A... Limit switch for materials handling application (pdf) download image`
Declaration of conformity
  • file image XC... limit switches - EU declaration of conformity (pdf) download image`
Product environmental
  • file image XCKJ10541 Metal Limit Switch, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image limit switch XC1AC - roller lever - 1C/O (pdf) download image`
RoHs Declaration
  • file image limit switch XC1AC - roller lever - 1C/O (pdf) download image`

Dimensions Drawings

Dimensions



(1)
3 tapped entries for Pg 13.5 cable gland


Adaptator Dimensions for IS0 M20 x 1.5





Connections and Schema

Wiring Diagram
Single-pole CO Slow Break





Technical Description

Characteristics of Actuation
Switch Actuation by 30° Cam





Functionnal Diagram



(1)
Closed
(2)
Open


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech