XACS413

$73.55
Special Order-Generally ships in 14 to 21 Business Days
SKU
XACS413

spring return contact block - 2 NO - front mounting, 30 or 40 mm centres

Main
Range of product
Harmony XAC
Product or component type
Contact block
Component name
XACS
Electrical circuit type
Control circuit
Contact block type
Single
Type of operator
Spring return
Product compatibility
XACA

ZA2B... head
Mechanical interlocking
Without mechanical interlock
Contacts type and composition
2 NO
Mounting of block
Front mounting
Contact operation
Slow-break
Complementary
Connections - terminals
Screw clamp terminals, connection capacity: 1 x 2.5 mm² with or without cable end

Screw clamp terminals, connection capacity: 2 x 1.5 mm² with or without cable end
Horizontal fixing centres
40 mm
Vertical fixing centres
30 mm
Mechanical durability
1000000 cycles
Contact code designation
A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A

Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V (degree of pollution: 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Resistance across terminals
<= 25 MOhm
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Rated operational power in W
42 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

45 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

60 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA
140 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)

385 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)

455 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)

525 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1
(13-14)NO

(23-24)NO
Terminal identifier
(11-12)NC

(13-14)NO
Product weight
0.07 kg
Environment
Standards
EN 60947-5-1

IEC 60947-5-1

CSA C22.2 No 14
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Vibration resistance
15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn conforming to IEC 60068-2-27
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XACS413

   Frequently Asked Questions and Answers


  • What is the part number for 6 hole pendant station with emergecy stop?

    There is no single part number for 6 hole pendant station with emergency stop it is made up of : XACA06 + XACA9412 + ZA2BS844 + ZB2BE101 + ZB2BE102 + LABELS to SUIT +++++      XACA06                                               XACA9412   &nbsp...
    Read more

  • What is Difference between zb2be101 and zb2be101c?

    The references with \'C\' at the end are products built in China and these products are dedicated to Chinese market. In fact the material used with suffix \'C\' is degraded compare to part reference without \'C\'. If ZB2BE101C needs to be replaced by ZB2BE101 than it is possible because they are same in size. Functionality wise there is no difference between both.  For further information, Please visit: https://www.schneider-electric.com.au/en/product-range-selector/661-harmony-xac/?p_url=http%3A%2F%2...
    Read more

  • Is the ZB4BP3 harmony pushbutton IP rated?

    Yes the ZB4BP3 is rated to IP69K.
    Read more

  • Video: Resetting a Harmony XB5R Wireless Push Button Receiver

    Issue: Reset the Wireless Receiver on the XB5R Wireless Push Button Product Line:  Push Button and Operator Interface  Environment: XB5R Wireless Push Buttons Resolution: 1. Hold down both buttons simultaneously  2. Wait for all of the lights to start flashing 3. Press both buttons down again until they go solid 4. Remove your fingers 5. Your device is now reset  
    Read more

  • What code is a Harmony flashing LED light block 240vac?

    ZBV18M1 = White ZBV18M3 = Green ZBV18M4 = Red ZBV18M5 = Yellow ZBV18M6 = Blue
    Read more

Certificate
  • file image XACB (Control circuit) Pendant control station (pdf) download image`
  • file image XAC, XAL, XAPS, XAW Control Stations (PDF) download image`
Declaration of conformity
  • file image XACB, XACF, XACM Pendant control station (pdf) download image`

Dimensions Drawings

Dimensions





Mounting and Clearance

Mounting





Performance Curves

Rated Operational Power
AC Supply 50/60 Hz

Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

Power broken in VA for 1 million operating cycles, AC-15 utilization category

Voltage

V

24

48

127

230

Inductive circuit

W

140

385

525

455

DC Supply

Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

Power broken in W for 1 million operating cycles, DC-13 utilization category

Voltage

V

24

48

120

Inductive circuit

W

60

45

42