XACB3191

$653.27
Special Order-Generally ships in 14 to 21 Business Days
SKU
XACB3191

pendant control station XAC-B - 2 pushbuttons 1 Emergency stop

Main
Range of product
Harmony XAC
Product or component type
Pendant control station
Device short name
XACB
Complementary
Control station type
Double insulated
Enclosure material
Glass reinforced polyester
Electrical circuit type
Power circuit
Enclosure type
Complete ready for use
Control station application
Control of single speed hoist motor
Control station composition
2 push-buttons + 1 emergency stop
Control button type
Stop push-button Ø 40 mm 3 NC latching

First push-button 2-pole raise, slow

Second push-button 2-pole lower, slow
Product compatibility
XESD1191 for reversing operation

XACS499 for emergency stop
Mechanical interlocking
With mechanical interlocking
Control station colour
Yellow
Connections - terminals
Screw clamp terminals 1 x 2.5 mm² with or without cable end

Screw clamp terminals 2 x 1.5 mm² with or without cable end
Standards
EN/IEC 60204-32

EN/IEC 60947-5-1

CSA C22.2 No 14
Product certifications
CSA type 4
Protective treatment
TH
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Vibration resistance
15 gn 10...500 Hz IEC 60068-2-6
Shock resistance
100 gn IEC 60068-2-27
Overvoltage category
Class II IEC 61140
IP degree of protection
IP65 IEC 60529
Mechanical durability
1000000 cycles
Cable entry
Rubber sleeve with stepped entry 10...22 mm
[Ithe] conventional enclosed thermal current
12 A
[Ui] rated insulation voltage
400 V 3 IEC 60947-1 emergency stop contact

600 V CSA
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
Contact operation
Snap action
Operating force
17 N push-button

40 N emergency stop
Short-circuit protection
<= 10 A fuse protection cartridge aM
Rated power in hp
2 hp CSA 240 V

3 hp CSA 600 V

5 hp CSA 400 V
Rated operational power in W
2200 W AC-3 240 V IEC 60947-3 appendix A

2200 W AC-3 400 V IEC 60947-3 appendix A

2200 W AC-4 240 V IEC 60947-3 appendix A

2200 W AC-4 400 V IEC 60947-3 appendix A
Electrical durability
300000 cycles AC-3 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

300000 cycles AC-3 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

300000 cycles AC-4 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

300000 cycles AC-4 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

500000 cycles AC-3 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

500000 cycles AC-4 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

800000 cycles AC-3 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A

800000 cycles AC-4 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
Terminals description ISO n°1
(13-14)NO

(23-24)NO

(33-34)NO

(43-44)NO
Terminals description ISO n°2
(11-12)NC

(21-22)NC

(31-32)NC
Terminal identifier
(11-12)NC

(13-14)NO
Product weight
0.94 kg
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:XACB3191

   Frequently Asked Questions and Answers


  • What is the part number for 6 hole pendant station with emergecy stop?

    There is no single part number for 6 hole pendant station with emergency stop it is made up of : XACA06 + XACA9412 + ZA2BS844 + ZB2BE101 + ZB2BE102 + LABELS to SUIT +++++      XACA06                                               XACA9412   &nbsp...
    Read more

  • What is Difference between zb2be101 and zb2be101c?

    The references with \'C\' at the end are products built in China and these products are dedicated to Chinese market. In fact the material used with suffix \'C\' is degraded compare to part reference without \'C\'. If ZB2BE101C needs to be replaced by ZB2BE101 than it is possible because they are same in size. Functionality wise there is no difference between both.  For further information, Please visit: https://www.schneider-electric.com.au/en/product-range-selector/661-harmony-xac/?p_url=http%3A%2F%2...
    Read more

  • Is the ZB4BP3 harmony pushbutton IP rated?

    Yes the ZB4BP3 is rated to IP69K.
    Read more

  • Video: Resetting a Harmony XB5R Wireless Push Button Receiver

    Issue: Reset the Wireless Receiver on the XB5R Wireless Push Button Product Line:  Push Button and Operator Interface  Environment: XB5R Wireless Push Buttons Resolution: 1. Hold down both buttons simultaneously  2. Wait for all of the lights to start flashing 3. Press both buttons down again until they go solid 4. Remove your fingers 5. Your device is now reset  
    Read more

  • What code is a Harmony flashing LED light block 240vac?

    ZBV18M1 = White ZBV18M3 = Green ZBV18M4 = Red ZBV18M5 = Yellow ZBV18M6 = Blue
    Read more

Instruction sheet
  • file image XACB... / XACM... Pendant control station, mounting with components (pdf) download image`
Certificate
  • file image XACB (Control circuit) Pendant control station (pdf) download image`
  • file image XAC, XAL, XAPS, XAW Control Stations (PDF) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech