XACA2174

Generally ships in 1 or 2 days
SKU
XACA2174

pendant station XAC-A pistol grip - 2 booted push buttons 1 Emergency stop



Main
Range of product
Harmony XAC
Product or component type
Pendant control station
Device short name
XACA pistol grip
Complementary
Control station type
Double insulated
Enclosure material
Polypropylene
Control type
Intuitive
Electrical circuit type
Control circuit
Enclosure type
Complete ready for use
Control station application
Control of 2-speed hoist motor
Control station composition
2 booted push-buttons + 1 emergency stop
Control button type
First push-button 2 NO raise, slow-fast

Second push-button 2 NO lower, slow-fast

Emergency stop push-button Ø 30 mm 1 NC trigger action
Product compatibility
ZB2BE102 for emergency stop

ZB2BE101 + ZB2BE201 for each direction
Mechanical interlocking
With mechanical interlocking
Control station colour
Yellow
Connections - terminals
Screw clamp terminals 1 x 2.5 mm² with or without cable end

Screw clamp terminals 2 x 1.5 mm² with or without cable end
Standards
EN/IEC 60204-32

EN/IEC 60947-5-1

EN/IEC 60947-5-5

EN/ISO 13850: 2006

UL 508

CSA C22.2 No 14
Product certifications
CSA

UL
Protective treatment
TH
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Vibration resistance
15 gn 10...500 Hz IEC 60068-2-6
Shock resistance
100 gn IEC 60068-2-27
Overvoltage category
Class II IEC 61140
IP degree of protection
IP65 IEC 60529
IK degree of protection
IK08 EN 50102
Mechanical durability
1000000 cycles
Cable entry
Rubber sleeve with stepped entry 7...15 mm
Contact code designation
A600 AC-15 240 V 3 A IEC 60947-5-1 appendix A

A600 AC-15 600 V 1.2 A IEC 60947-5-1 appendix A

Q600 DC-13 250 V 0.27 A IEC 60947-5-1 appendix A

Q600 DC-13 600 V 0.1 A IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
600 V 3 IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
Contact operation
Slow-break

Staggered
Resistance across terminals
<= 25 MOhm
Operating force
13...15 N
Short-circuit protection
10 A fuse protection cartridge gG
Rated operational power in W
40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C

48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C

65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
Terminals description ISO n°1
(13-14)NO

(23-24)NO_CL
Terminals description ISO n°2
(11-12)NC
Terminal identifier
(11-12)NC

(13-14)NO
Product weight
0.36 kg
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Loading...
Write Your Own Review
You're reviewing:XACA2174
Instruction sheet
  • file image XAC A... Pendant control stations (pdf) download image`
  • file image XAC A... Pendant control stations with intuitive operation (Pistol Grip), Instruction Sheet (pdf) download image`
CAD
  • file image Pendant control stations 6, double insulated with intuitive operation For control of 2-speed hoist motors, 2 operators + 1 latching Emergency (dwf) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of 2-speed hoist motors, 2 operators + 1 latching Emergency (dwg) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of 2-speed hoist motors, 2 operators + 1 latching Emergency (dxf) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of 2-speed hoist motors, 2 operators + 1 latching Emergency (wmf) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of speed hoist motors, 2 operators + 1 latching Emergency (dwf) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of speed hoist motors, 2 operators + 1 latching Emergency (dwg) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of speed hoist motors, 2 operators + 1 latching Emergency (dxf) download image`
  • file image Pendant control stations 6, double insulated with intuitive operation For control of speed hoist motors, 2 operators + 1 latching Emergency (wmf) download image`
Certificate
  • file image XAC-A Pendant control stations (Pistol) (pdf) download image`
  • file image XACA Pendant control station (pdf) download image`
Declaration of conformity
  • file image XACA... Pendant control stations Pistol grip (pdf) download image`
REACh Declaration
  • file image pendant station XAC-A pistol grip - 2 booted push buttons 1 Emergency stop (pdf) download image`
RoHs Declaration
  • file image pendant station XAC-A pistol grip - 2 booted push buttons 1 Emergency stop (pdf) download image`

Dimensions Drawings

Dimensions



(1)
With trigger action latching Ø 30 mm / 1.18 in. Emergency stop.
(2)
Internal Ø


Connections and Schema

Control of 2-Speed Reversing Motor





Performance Curves

Rated Operational Power
AC Supply 50/60 Hz Inductive Circuit

Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

Millions of operating cycles, AC-15 utilization category



Ithe
Thermal current
(A)
Current
DC Supply

Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

Power broken in W for 1 million operating cycles, DC-13 utilization category

Voltage

V

24

48

120

Inductive circuit

W

65

48

40



© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech