VW3A3310D

$858.85
Generally ships in 1 to 2 days
SKU
VW3A3310D

Modbus TCP communication card - 1 RJ45 - 10/100 Mbps

Main
Product or component type
Communication card
Range compatibility
Altivar 61

Altivar 71

Altivar 61Q

Altivar 71Q
Communication port protocol
Modbus TCP
Product specific application
For daisy chain mounting
Connector type
1 RJ45
Transmission rate
10 Mbps

100 Mbps
Physical interface
Ethernet 2
Web services
Altivar chart

Altivar viewer

Data editor

E-mail

Ethernet statistics

FDR Agent

IO Scanner

Security
Complementary
Exchange mode
Half duplex and full duplex
Communication data link
LLC : IEEE 802.2

MAC : IEEE 802.3
Communication network type
IP conforming to RFC791
Communication transport type
8 connections maximum

TCP conforming to RFC793

UDP
Concept
Transparent Ready class C20
Web server
Embedded
Communication service
CiA 402 profile

Communication monitoring can be inhibited, adjustable

Diagnostics (08)

FTP

I/O profile

I/O scanning service can be inhibited

Read device identification (43)

Read holding registers (03)

Read input registers (04)

Read/write multiple registers (23)

SNMP

TFTP

Write multiple registers (16)

Write single register (06)
Display type
1 LED for 10/100 Mbps (speed)

1 LED for FLT (Ethernet fault)

1 LED for RX (reception)

1 LED for STS (IP address)

1 LED for TX (transmission)

Graphic display terminal for control word received

Graphic display terminal for reference received

Web server
Product weight
0.3 kg
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:VW3A3310D

   Frequently Asked Questions and Answers


  • What supplies the power to vw3a3401 encoder interface card fitted on Altivar 71?

    The encoder interface card VW3A3401 uses an internal 5VDC supply from the drive control block. The interface card supplies 5VDC to the encoder RS422 with maximum current available up to 200mA.
    Read more

  • When does the Drive Overheat Fault (OHF) occur in Altivar 71 Drives.

    The Drive Overheat Fault (OHF) indicates that the heat sink temperature has crossed the temperature threshold. This is the information from the temperature sensor located on the heat sink, near the transistor module. When the Thermal Heat Dissipation (THD) is greater than 118% it trips in OHF. 118% is approximately 100 Deg Centigrade temperature on the heat sink. The main causes for the occurrence of this fault are: 1. Excessive ambient temperature. (Provide proper air cooling of the control roo...
    Read more

  • Altivar 61/71 what is the recommended corrective action when the motor runs in reverse with a run forward command?

    Issue: The motor is running backwards with a forward run command on the drive. Product line: Altivar ATV61 and ATV71 Environment: All models, all serial numbers Cause: The phase rotation is inverted coming out of the drive going to the motor.      Resolution: Option 1: To correct the motor rotation swap two motor leads on the drive output terminals. Option 2: Go in the simple start menu 1.1 find output phase rotation change it from ABC to ACB. Refer to the ATV61 and ATV71 programm...
    Read more

  • What does ramp increment mean for the Altivar 61/71?

    Issue:  What does ramp increment mean for the Altivar 61/71?   Product Line: Altivar 61, Altivar 71   Environment: All serial numbers   Cause: N/A   Resolution: Ramp increment is a parameter that will change the resolution of the listed parameters:  see below Inr M [Ramp increment] 0.01 - 0.1 - 1 0.1 0.01   [0.01]: Ramp up to 99.99 seconds 0.1     [0.1]: Ramp up to 999.9 seconds 1        [1]: Ramp up to 9,000 s...
    Read more

  • Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes on VFD?

    Issue:  Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes? Product Line:   Altivar 61 Altivar 71 ATV61  ATV71 Environment: All Cause: Define the No Drive Fault relay relationship with Auto restart function.  Resolution: The relay assigned to No Drive Fault will not change states on a fault, if Auto restart is set to YES, until the max restart time is depleted and the fault still exists.
    Read more

User guide
  • file image ATV IMC Hardware Guide (pdf) download image`
  • file image ATV IMC Drive Controller, Programming Guide (pdf) download image`
Catalogue
  • file image Catalog: Altivar 71/71 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
  • file image Catalog: Altivar 61/61 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech