VW3A3202

$426.78
Special Order-Generally ships in 14 to 21 Business Days
SKU
VW3A3202

extended I/O card - for ATV61/ATV71

Main
Product or component type
Extended I/O card
Range compatibility
Altivar 71Q

Altivar Lift

Altivar 61

Altivar 71

Altivar 61Q
Supply
Internal supply for reference potentiometer, 10.5 V DC (10...11 V) , <= 0.01 A, impedance: 1...10 kOhm for overload and short-circuit protection

Internal supply, 24 V DC (21...27 V) , <= 0.2 A for overload and short-circuit protection
Analogue input number
2
Analogue input type
AI3-/Al3+ differential current programmable : 0...20 mA, impedance: 250 Ohm, sampling time: 4...6 ms, resolution: 11 bits + sign

AI4 software-configurable current : 0...20 mA, impedance: 250 Ohm, sampling time: 4...6 ms, resolution: 11 bits

AI4 software-configurable voltage : 0...10 V DC, 24 V max, impedance: 30000 Ohm, sampling time: 4...6 ms, resolution: 11 bits
Analogue output number
2
Analogue output type
AO2 software-configurable current : 0...20 mA, impedance: 500 Ohm, sampling time: 4...6 ms, resolution: 10 bits

AO3 software-configurable current : 0...20 mA, impedance: 500 Ohm, sampling time: 4...6 ms, resolution: 10 bits

AO2 software-configurable voltage : +/- 10 V DC, impedance: 470 Ohm, sampling time: 4...6 ms, resolution: 10 bits

AO3 software-configurable voltage : +/- 10 V DC, impedance: 470 Ohm, sampling time: 4...6 ms, resolution: 10 bits
Discrete output number
5
Discrete output type
(LO3, LO4) assignable logic, sampling time: 4...6 ms, compatible with level 1 PLC

(R4A, R4B, R4C) configurable relay logic
Discrete output logic
(LO3, LO4) negative

(LO3, LO4) positive
Discrete input number
6
Discrete input type
(RP) frequency control, , sampling time: 4...6 ms

(LI11...LI14) programmable, , compatible with level 1 PLC, impedance: 3.5 kOhm, sampling time: 4...6 ms
Discrete input logic
(LI11...LI14) negative state 0 >= 16 V state 1 <= 10 V

(LI11...LI14) positive state 0 <= 5 V state 1 >= 11 V

(RP) positive state 0 < 1.2 V state 1 >= 3.5 V
Complementary
Electrical durability
100000 cycles for configurable relay logicoutput(s)
Discrete output voltage
24 V DC (voltage limits:<= 30 V) assignable logic
Maximum output current
0.2 A, assignable logic
Minimum switching current
Configurable relay logic 3 mA for 24 V DC
Maximum switching current
Configurable relay logic 5 A at 250 V AC on resistive load, cos phi = 1

Configurable relay logic 5 A at 30 V DC on resistive load, cos phi = 1

Configurable relay logic 1.5 A at 250 V AC on inductive load, cos phi = 0.4 and L/R = 7 ms

Configurable relay logic 1.5 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 7 ms
PTC probe input
TH2+, TH2- trip resistance, impedance: 3 kOhm

TH2+, TH2- reset resistance, impedance: 1.8 Ohm

TH2+, TH2- short circuit protection, impedance: < 0.05 Ohm

TH2+, TH2- for 6 PTC probe, impedance: <= 1.5 Ohm
Discrete input voltage
24 V DC (voltage limits:<= 30 V) for programmable
Discrete input frequency
0...30 kHz frequency control
Electrical connection
Terminal, 1.5 mm² / AWG 16, 0.25 N.m
Product weight
0.3 kg
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:VW3A3202

   Frequently Asked Questions and Answers


  • What supplies the power to vw3a3401 encoder interface card fitted on Altivar 71?

    The encoder interface card VW3A3401 uses an internal 5VDC supply from the drive control block. The interface card supplies 5VDC to the encoder RS422 with maximum current available up to 200mA.
    Read more

  • When does the Drive Overheat Fault (OHF) occur in Altivar 71 Drives.

    The Drive Overheat Fault (OHF) indicates that the heat sink temperature has crossed the temperature threshold. This is the information from the temperature sensor located on the heat sink, near the transistor module. When the Thermal Heat Dissipation (THD) is greater than 118% it trips in OHF. 118% is approximately 100 Deg Centigrade temperature on the heat sink. The main causes for the occurrence of this fault are: 1. Excessive ambient temperature. (Provide proper air cooling of the control roo...
    Read more

  • Altivar 61/71 what is the recommended corrective action when the motor runs in reverse with a run forward command?

    Issue: The motor is running backwards with a forward run command on the drive. Product line: Altivar ATV61 and ATV71 Environment: All models, all serial numbers Cause: The phase rotation is inverted coming out of the drive going to the motor.      Resolution: Option 1: To correct the motor rotation swap two motor leads on the drive output terminals. Option 2: Go in the simple start menu 1.1 find output phase rotation change it from ABC to ACB. Refer to the ATV61 and ATV71 programm...
    Read more

  • What does ramp increment mean for the Altivar 61/71?

    Issue:  What does ramp increment mean for the Altivar 61/71?   Product Line: Altivar 61, Altivar 71   Environment: All serial numbers   Cause: N/A   Resolution: Ramp increment is a parameter that will change the resolution of the listed parameters:  see below Inr M [Ramp increment] 0.01 - 0.1 - 1 0.1 0.01   [0.01]: Ramp up to 99.99 seconds 0.1     [0.1]: Ramp up to 999.9 seconds 1        [1]: Ramp up to 9,000 s...
    Read more

  • Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes on VFD?

    Issue:  Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes? Product Line:   Altivar 61 Altivar 71 ATV61  ATV71 Environment: All Cause: Define the No Drive Fault relay relationship with Auto restart function.  Resolution: The relay assigned to No Drive Fault will not change states on a fault, if Auto restart is set to YES, until the max restart time is depleted and the fault still exists.
    Read more

User guide
  • file image ATV71W/E5 Simplified manual (pdf) download image`
  • file image ATV61W/E5 Simplified manual (pdf) download image`
  • file image ATV IMC Hardware Guide (pdf) download image`
  • file image ATV IMC Drive Controller, Programming Guide (pdf) download image`
Catalogue
  • file image Catalog: Altivar 71/71 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
  • file image Catalog: Altivar 61/61 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
  • file image Altivar IMC Drive controller (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech