TSXCANKCDF180T

$179.49
Special Order-Generally ships in 14 to 21 Business Days
SKU
TSXCANKCDF180T

CANopen SUB-D9 female connector - straight - IP20

Main
Range of product
CANopen
Bus type
CANopen
Accessory / separate part category
Connection accessories
Accessory / separate part type
Connector with line terminator
IP degree of protection
IP20
Accessory / separate part destination
CANopen bus
Complementary
Electrical connection
1 female connector 9 straight
Product weight
0.049 kg
Offer Sustainability
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:TSXCANKCDF180T

   Frequently Asked Questions and Answers


  • What supplies the power to vw3a3401 encoder interface card fitted on Altivar 71?

    The encoder interface card VW3A3401 uses an internal 5VDC supply from the drive control block. The interface card supplies 5VDC to the encoder RS422 with maximum current available up to 200mA.
    Read more

  • When does the Drive Overheat Fault (OHF) occur in Altivar 71 Drives.

    The Drive Overheat Fault (OHF) indicates that the heat sink temperature has crossed the temperature threshold. This is the information from the temperature sensor located on the heat sink, near the transistor module. When the Thermal Heat Dissipation (THD) is greater than 118% it trips in OHF. 118% is approximately 100 Deg Centigrade temperature on the heat sink. The main causes for the occurrence of this fault are: 1. Excessive ambient temperature. (Provide proper air cooling of the control roo...
    Read more

  • Altivar 61/71 what is the recommended corrective action when the motor runs in reverse with a run forward command?

    Issue: The motor is running backwards with a forward run command on the drive. Product line: Altivar ATV61 and ATV71 Environment: All models, all serial numbers Cause: The phase rotation is inverted coming out of the drive going to the motor.      Resolution: Option 1: To correct the motor rotation swap two motor leads on the drive output terminals. Option 2: Go in the simple start menu 1.1 find output phase rotation change it from ABC to ACB. Refer to the ATV61 and ATV71 programm...
    Read more

  • What does ramp increment mean for the Altivar 61/71?

    Issue:  What does ramp increment mean for the Altivar 61/71?   Product Line: Altivar 61, Altivar 71   Environment: All serial numbers   Cause: N/A   Resolution: Ramp increment is a parameter that will change the resolution of the listed parameters:  see below Inr M [Ramp increment] 0.01 - 0.1 - 1 0.1 0.01   [0.01]: Ramp up to 99.99 seconds 0.1     [0.1]: Ramp up to 999.9 seconds 1        [1]: Ramp up to 9,000 s...
    Read more

  • Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes on VFD?

    Issue:  Will the relay output, assigned to No Drive Fault, change states on a fault if Auto restart is set to yes? Product Line:   Altivar 61 Altivar 71 ATV61  ATV71 Environment: All Cause: Define the No Drive Fault relay relationship with Auto restart function.  Resolution: The relay assigned to No Drive Fault will not change states on a fault, if Auto restart is set to YES, until the max restart time is depleted and the fault still exists.
    Read more

User guide
  • file image TeSys U CANopen - Quick Start Guide (pdf) download image`
Catalogue
  • file image Catalog: Altivar 71/71 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
  • file image Catalog: Altivar 61/61 Plus variable speed drives - English version 2014/04 (web pdf format) (pdf) download image`
  • file image Catalogue Modicon M340 automation platform - English version 2014/09 (web pdf format) (pdf) download image`
  • file image Catalog: Altivar 32 variable speed drives (pdf) download image`
  • file image CANopen for Machines (pdf) download image`
  • file image Altivar Machine ATV320 variable speed drives - Catalog (pdf) download image`
  • file image Modicon M251 logic controllers (pdf) download image`
  • file image Catalog: Altivar Process ATV600 variable speed drives - English version 2018/05 (pdf) (pdf) download image`
RoHs Declaration
  • file image CANopen SUB-D9 female connector - straight - IP20 (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech