TCSESM083F23F0

$3,364.66
Special Order-Generally ships in 14 to 21 Business Days
SKU
TCSESM083F23F0

Ethernet TCP/IP managed switch - ConneXium - 8 ports for copper

Main
Range of product
ConneXium
Product or component type
Ethernet TCP/IP managed switch
Concept
Transparent Ready
Communication port protocol
Ethernet TCP/IP
Port Ethernet
10BASE-T/100BASE-TX - 8 port(s) copper cable
Maximum number of switches in cascade
Unlimited
Complementary
Integrated connection type
Shielded RJ45 copper cable
Transmission support medium
Twisted shielded pairs cable CAT 5E for copper cable
Ethernet service
Configuration via web server

Data stream control

FDR

IGMP Snooping

Multicast filtering

Priority port

Rapid Scanning Tree Protocol (RSTP)

Secure port

SMTP V3

SNTP client

VLAN
Maximum number of switches in a ring
50
Redundancy
Redundant power supplies

Redundant single ring

Ring coupling
[Us] rated supply voltage
24 V
Supply voltage limits
18...30 V AC SELV

9.6...60 V DC SELV
Power consumption in W
5.3 W
Electrical connection
Removable connector 6 ways power supply
Mounting support
35 mm symmetrical DIN rail
Marking
CE
Local signalling
1 LED fault

2 LEDs P1 P2 power supplies

1 LED ring manager

1 LED stand-by

1 LED per channel copper port activity

1 LED per channel copper port status
Alarm output
1 voltfree contact 1 A
Alarm function
Power supply fault

Switch fault

Data link status

Redundancy ring fault
Ethernet cabling system
TF switches
Width
74 mm
Height
131 mm
Depth
111 mm
Product weight
0.41 kg
Environment
Relative humidity
10...95 % without condensation
IP degree of protection
IP20
Standards
EN/IEC 61131-2

UL 1604 Class 1 Division 2

UL 508

CSA C22.2 No 213 Class I Division 2

CSA C22.2 No 214
Product certifications
C-Tick

GL
Ambient air temperature for operation
0...60 °C
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
Need no specific recycling operations
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:TCSESM083F23F0

   Frequently Asked Questions and Answers


  • What are the part numbers for SoMachine version 4.3?

    Issue: Need to know the part numbers for the programming Software SoMachine version 4.3. Product Line: PLC Programming software Resolution: The part numbers for SoMachine version 4.3 are: - SOMNACS43 + trial license for V4.3 (21days) - USB flash drive. The USB flash drive is mandatory and supplied with a trial license. - SOMNACCZXSPAZZ 1 (Single License) - SOMNACCZXTPAZZ 10 (Team License) - SOMNACCZXEPAZZ 100 (Entity License) Supported controllers: - Logic controllers: Modicon M238, Modicon M241, Mod...
    Read more

  • What is the maximum number of analog channels that a Modicon M221 Logic Controller can have?

    The maximum number of analog channels that a Modicon M221 Logic Controllers can have are as follows: For 16 & 24 IO Base Module: 116 analog I/O: 7 modules on the main PLC (each with up to 8 analog I/O) + 7 modules on the Remote I/O (each with up to 8 analog I/O) + One I/O option cartrige (with two analog I/O). + 2 onboard analog input I/O. Modicon M221 Book Logic Controllers do not have an I/O option cartrige slot. For 40 IO Base Module: 118 analog I/O: 7 modules on the main PLC (each...
    Read more

  • What are the functions of a SD card of a M221 logic controller?

    The Modicon M221 Logic Controller allows the following types of file management with an SD card: - Clone management: back up or restore a complete controller (using an empty SD card) - Firmware management: put and get firmware on the controller - User application management: put and get the user application on a controller - Post configuration management: put, change, or remove post configuration information on a controller - Error log management: get or delete an error log file from a controller - Data ...
    Read more

  • Video: Cascading Write_Read_Var Example in SoMachine 4.1

    Tutorial for creating a Cascading Write_Read_Var in SoMachine 4.1 with Modicon M251 logic controller over Modbus TCP.   Cascading_write_read_var.projectarchive
    Read more

  • How do I transfer information between PLC to PLC via Modbus Plus ?

    You can use either Peer Cop from the Configuration screens, or use the MSTR block. The MSTR Block can be used to transfer data through a read or write function, or through transfer of global data. The Peer cop is independant of the MSTR block. The MSTR block is explained in Modfax document #4534 or the Modicon Ladder Logic Block Library Users Guide , 840USE10100. Peer Cop is expalined in the Modbus Plus Planning & Installation Guide 890USE10000. Each of these manuals can be found on our web site at w...
    Read more

User guide
  • file image TCSESM Managed Switch, Installation Manual (pdf) download image`
  • file image TCSESM, TCSESM-E Managed Switch, Redundancy Configuration User Manual (pdf) download image`
  • file image TCSESM, TCSESM-E Managed Switch Command Line Interface, Reference Manual (pdf) download image`
Catalogue
  • file image Ethernet pour les machines (pdf) download image`
Declaration of conformity
  • file image DCE_CONNEXIUM_MAY2018 (pdf) download image`
Product environmental
  • file image PEP Connexium (pdf) download image`
REACh Declaration
  • file image Ethernet TCP/IP managed switch - ConneXium - 8 ports for copper (pdf) download image`
RoHs Declaration
  • file image Ethernet TCP/IP managed switch - ConneXium - 8 ports for copper (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech