LU2B32BL

power base - TeSys U - 32 A - 24 V DC screw clamps control
SKU
LU2B32BL
$730.22
Documents and Downloads
User guide
  • TeSysU Communication Variables (EN) (pdf)
  • TeSys U - Use in explosive atmospheres (pdf)
Instruction sheet
  • LU2B./LU2M./LU6M. - TeSys U reversing power bases (pdf)
  • LUB.+LUCA/LUCB/LUCC/LUCD - TeSys U power base + control units (pdf)
CAD
  • Starter-controlerspower bases for reversing starting (dwf)
  • Starter-controlerspower bases for reversing starting (dwg)
  • Starter-controlerspower bases for reversing starting (dxf)
  • Starter-controlerspower bases for reversing starting (wmf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwg)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dxf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (wmf)
  • Starter-controllerspower bases for reversing starting (dwf)
  • Starter-controllerspower bases for reversing starting (dwg)
  • Starter-controllerspower bases for reversing starting (dxf)
  • Starter-controllerspower bases for reversing starting (wmf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwg)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dxf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (wmf)
  • Starter-controlerspower bases for reversing starting (dwf)
  • Starter-controlerspower bases for reversing starting (dwg)
  • Starter-controlerspower bases for reversing starting (dxf)
  • Starter-controlerspower bases for reversing starting (wmf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwg)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dxf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (wmf)
  • Starter-controlerspower bases for reversing starting (dwf)
  • Starter-controlerspower bases for reversing starting (dwg)
  • Starter-controlerspower bases for reversing starting (dxf)
  • Starter-controlerspower bases for reversing starting (wmf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dwg)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (dxf)
  • Starter-controlerspower bases for reversing startingwith prewired control circuit components (wmf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwg)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dxf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (wmf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dwg)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (dxf)
  • Starter-controlerspower bases for reversing startingwith multifunction control units (wmf)
  • Starter-controllerspower bases for reversing starting (dwf)
  • Starter-controllerspower bases for reversing starting (dwg)
  • Starter-controllerspower bases for reversing starting (dxf)
  • Starter-controllerspower bases for reversing starting (wmf)
  • REVERSER (zip)
  • REVERSER (stp)
Declaration of conformity
  • EU Declaration TeSys U - TeSys U (pdf)
  • EU Declaration TeSys U - TeSys U Atex (pdf)
End of life manual
  • TeSys LC1K09-K16 - EoLi (pdf)
Product environmental
  • TeSys LC1K09-K16 - PEP (pdf)
Description
power base - TeSys U - 32 A - 24 V DC screw clamps control
More Information
More Information
product or component typeReversing power base
Control Circuit Voltage24 V
[Ith] conventional free air thermal current32 A
Reviews
Write Your Own Review
Characterstics
Main
Range
TeSys
Product name
TeSys U
Device short name
LU2B
Product or component type
Reversing power base
Device application
Motor
Poles description
3P
Suitability for isolation
Yes
[Ith] conventional free air thermal current
32 A
Utilisation category
AC-41

AC-43

AC-44
[Uc] control circuit voltage
24 V DC
Complementary
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1

Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
[Ue] rated operational voltage
230 V

440 V

500 V

690 V
Network frequency
40...60 Hz
[Ie] rated operational current
21 A at 690 V

23 A at 500 V

32 A at <= 440 V
[Ics] rated service breaking capacity
10 kA 500 V

4 kA 690 V

50 kA 230 V

50 kA 440 V
Control circuit voltage limits
14.5 V 24 V DC drop-out

20...27 V 24 V DC in operation
Typical current consumption
120 mA at 24 V DC I maximum while closing

120 mA at 24 V DC I rms sealed
Inrush restraint duration
15 ms for DC network
Safety reliability level
B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time
150 ms with change of direction for power circuit

35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit

70 ms closing with LUCA, LUCB, LUCC, LUCD for control circuit

75 ms closing with LUCM for control circuit

75 ms without change of direction for power circuit
Mechanical durability
15000000 cycles
Operating rate
60 cyc/mn
[Ui] rated insulation voltage
600 V conforming to CSA C22.2 No 14

600 V conforming to UL 508

690 V conforming to IEC 60947-1 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N

400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Connections - terminals
Power circuit : screw clamp terminals 2 cable 1.5...6 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 1 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end

Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end

Control circuit : screw clamp terminals 2 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end

Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end

Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end

Power circuit : screw clamp terminals 1 cable 1...10 mm² - cable stiffness: rigid - without cable end

Power circuit : screw clamp terminals 1 cable 1...6 mm² - cable stiffness: flexible - with cable end

Power circuit : screw clamp terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end

Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: flexible - with cable end

Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: rigid - without cable end
Tightening torque
Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm flat

Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm Philips no 1

Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm flat

Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm Philips No 2
Width
45 mm
Height
224 mm
Depth
126 mm
Product weight
1.27 kg
Environment
IP degree of protection
IP20 front panel and wired terminals conforming to IEC 60947-1

IP20 other faces conforming to IEC 60947-1

IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-25...60 °C with LUCM

-25...70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage
-40...85 °C
Fire resistance
650 °C conforming to IEC 60695-2-12

960 °C parts supporting live components conforming to IEC 60695-2-12
Operating altitude
2000 m
Shock resistance
10 gn power poles open conforming to IEC 60068-2-27

15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance
2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27

4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge
8 kV level 3 in open air conforming to IEC 61000-4-2

8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields
10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients
2 kV class 3 serial link conforming to IEC 61000-4-4

4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Non-dissipating shock wave
0 kV 24 V DC

1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2

2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
Immunity to radioelectric fields
10 V conforming to IEC 61000-4-6
Heat dissipation
3 W for control circuit with LUCA, LUCB, LUCC, LUCD

1.8 W for control circuit with LUCM
Immunity to microbreaks
3 ms
Immunity to voltage dips
70 % 500 ms conforming to IEC 61000-4-11
Product certifications
ABS

ASEFA

ATEX

BV

CCC

CSA

DNV

GL

GOST

LROS (Lloyds register of shipping)

UL
Standards
CSA C22.2 No 14 type E

EN 60947-6-2

IEC 60947-6-2

UL 508 type E with phase barrier
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months