power base - TeSys U - 32 A - 24 V DC screw clamps control
SKU
LU2B32BL
$730.22
User guide
Instruction sheet
CAD
Declaration of conformity
End of life manual
Product environmental
power base - TeSys U - 32 A - 24 V DC screw clamps control
product or component type | Reversing power base |
---|---|
Control Circuit Voltage | 24 V |
[Ith] conventional free air thermal current | 32 A |
Write Your Own Review
Main
- Range
- TeSys
- Product name
- TeSys U
- Device short name
- LU2B
- Product or component type
- Reversing power base
- Device application
- Motor
- Poles description
- 3P
- Suitability for isolation
- Yes
- [Ith] conventional free air thermal current
- 32 A
- Utilisation category
- AC-41
AC-43
AC-44 - [Uc] control circuit voltage
- 24 V DC
Complementary
- Auxiliary contact composition
- 1 NO + 1 NC
- Auxiliary contacts type
- Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1 - [Ue] rated operational voltage
- 230 V
440 V
500 V
690 V - Network frequency
- 40...60 Hz
- [Ie] rated operational current
- 21 A at 690 V
23 A at 500 V
32 A at <= 440 V - [Ics] rated service breaking capacity
- 10 kA 500 V
4 kA 690 V
50 kA 230 V
50 kA 440 V - Control circuit voltage limits
- 14.5 V 24 V DC drop-out
20...27 V 24 V DC in operation - Typical current consumption
- 120 mA at 24 V DC I maximum while closing
120 mA at 24 V DC I rms sealed - Inrush restraint duration
- 15 ms for DC network
- Safety reliability level
- B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Operating time
- 150 ms with change of direction for power circuit
35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
70 ms closing with LUCA, LUCB, LUCC, LUCD for control circuit
75 ms closing with LUCM for control circuit
75 ms without change of direction for power circuit - Mechanical durability
- 15000000 cycles
- Operating rate
- 60 cyc/mn
- [Ui] rated insulation voltage
- 600 V conforming to CSA C22.2 No 14
600 V conforming to UL 508
690 V conforming to IEC 60947-1 3 - [Uimp] rated impulse withstand voltage
- 6 kV conforming to IEC 60947-6-2
- Safe separation of circuit
- 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N - Connections - terminals
- Power circuit : screw clamp terminals 2 cable 1.5...6 mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminals 1 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end
Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end
Control circuit : screw clamp terminals 2 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end
Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end
Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end
Power circuit : screw clamp terminals 1 cable 1...10 mm² - cable stiffness: rigid - without cable end
Power circuit : screw clamp terminals 1 cable 1...6 mm² - cable stiffness: flexible - with cable end
Power circuit : screw clamp terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end
Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: flexible - with cable end
Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: rigid - without cable end - Tightening torque
- Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm flat
Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm Philips no 1
Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm flat
Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm Philips No 2 - Width
- 45 mm
- Height
- 224 mm
- Depth
- 126 mm
- Product weight
- 1.27 kg
Environment
- IP degree of protection
- IP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1 - Protective treatment
- TH conforming to IEC 60068
- Ambient air temperature for operation
- -25...60 °C with LUCM
-25...70 °C with LUCA, LUCB, LUCC, LUCD - Ambient air temperature for storage
- -40...85 °C
- Fire resistance
- 650 °C conforming to IEC 60695-2-12
960 °C parts supporting live components conforming to IEC 60695-2-12 - Operating altitude
- 2000 m
- Shock resistance
- 10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27 - Vibration resistance
- 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27
4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27 - Resistance to electrostatic discharge
- 8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2 - Resistance to radiated fields
- 10 V/m 3 conforming to IEC 61000-4-3
- Resistance to fast transients
- 2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 - Non-dissipating shock wave
- 0 kV 24 V DC
1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
2 kV common mode 24...240 V AC conforming to IEC 60947-6-2 - Immunity to radioelectric fields
- 10 V conforming to IEC 61000-4-6
- Heat dissipation
- 3 W for control circuit with LUCA, LUCB, LUCC, LUCD
1.8 W for control circuit with LUCM - Immunity to microbreaks
- 3 ms
- Immunity to voltage dips
- 70 % 500 ms conforming to IEC 61000-4-11
- Product certifications
- ABS
ASEFA
ATEX
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
UL - Standards
- CSA C22.2 No 14 type E
EN 60947-6-2
IEC 60947-6-2
UL 508 type E with phase barrier
Offer Sustainability
- Sustainable offer status
- Green Premium product
- RoHS (date code: YYWW)
- Schneider Electric declaration of conformity
- REACh
- Reference not containing SVHC above the threshold
- Product environmental profile
- Product Environmental Profile
- Product end of life instructions
- End of Life Information
Contractual warranty
- Warranty period
- 18 months