HMIG3U

$1,924.78
Generally ships in 1 to 2 days
SKU
HMIG3U

Premium BOX for Universal Panel

Main
Range of product
Magelis GTU
Product or component type
Base unit
Device short name
Premium Box
Processor name
CPU RISC 600 MHz
Operating system
Magelis
Software package
Vijeo Designer run time
Complementary
Range compatibility
Magelis GTU
Data storage equipment
1 GB SD card
Port Ethernet
10BASE-T/100BASE-TX/1000BASE-T
Memory description
Backup memory 512 kB NVRAM

Internal 256 MB RAM 2 x 13 mm board
Type of cooling
Natural convection
Integrated connection type
USB 2.0 port mini B USB

Auxiliary port terminal block

Expansion unit fieldbus card

Ethernet TCP/IP with 2 RJ45

COM1 serial link RJ45 RS485, transmission rate: 110...115200 bit/s

COM1 serial link RJ45 RS485, transmission rate: 187.5 kbit/s

COM2 serial link SUB-D 9 RS232C/RS422/RS485, transmission rate: 110...115200 bit/s

COM2 serial link SUB-D 9 RS232C/RS422/RS485, transmission rate: 187.5 kbit/s

USB 2.0 port with 2 USB type A
Communication port protocol
Modbus TCP/IP

Modbus

Uni-Telway
[Us] rated supply voltage
12...24 V DC power supply
Depth
45 mm
Height
131 mm
Width
188 mm
Product weight
0.9 kg
Number of slots available for expansion
2 SD card
Environment
Standards
CSA C22.2 No 142

ANSI/ISA 12-12-01

CSA C22.2 No 213 class I division 2

IEC 61132-2

UL 508
Product certifications
CCS

EAC

KC

ATEX

RCM

CUL

IEC-Ex

GL

ABS

BV

DNV

LR

RINA

CULus

CE
Pollution degree
2 conforming to EN 61131-2 Ed.3
Electromagnetic compatibility
Electrostatic discharge immunity test EN/IEC 61000-4-2 level 3
Ambient air temperature for storage
-20...60 °C
Relative humidity
10...90 % non-condensing
Ambient air temperature for operation
0...60 °C
Operating altitude
2000 m
Vibration resistance
3.5 mm constant amplitude 5...9 Hz conforming to EN/IEC 61131-2

9.8 m/s² 9...150 Hz conforming to EN/IEC 61131-2
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months 18 months
Write Your Own Review
You're reviewing:HMIG3U

   Frequently Asked Questions and Answers


  • Can the Magelis HMIGTU series be configured with SoMachine v4.1?

    Currently, the new HMIGTU terminals cannot be configured with SoMachine v4.1. The new terminals Magelis GTU will be available in future SoMachine software with Vijeo Designer V6.2 SP3 scheduled Q2 2015.
    Read more

  • Can the HMIG3U play a sound file?

    Issue: Is it possible to play a sound file when an alarm occurs with the Magelis HMIG3U? Product Line HMIG3U Environment: Vijeo Designer V6.2 SP8 Resolution: The HMIG3U can play sounds through the AUX port.  You will need to get this Schneider Electric connector HMIZGAUX.  The Speaker output on the AUX is rated for 300 mW (Rated Load: 8 Ω, Frequency: 1 kHz) It supports sounds files that are 16-bit mono PCM or IMA ADPCM with 8, 12, or 16 kHz sampling rate. If you use a 11....
    Read more

  • Is there a HMI touchsceen with Wi-Fi capabilities

    Yes.  The Magelis HMIGTU 12\' Display includes Wireless Lan capabilities. The Innovative Access Point embedded in HMI to provide easy, robust and secure wireless connection to Industrial architecture. This Display is available only with the last version of Magelis GTU Open Box PV02/SV2.0 or later AND VijeoDesigner software version V6.2 SP3. This unit will be available in June 2015.  The part number is HMIDT643.
    Read more

  • Video: How to recover the system on the HMIGTU Series?

    Recovering the System on the HMIG3U   Goals and Symptoms        Currently, our HMIG3U is provided only with the SD Card system. The goal of this resolution is to provide the system recovery resource that can be used to backup and recover HMIGTU Series.   Causes and Fixes        The Backup Recovery Tool has been validated. Attached, please find the BackupRecovery.exe and Backup Recovery User Manual You can also find an pre-m...
    Read more

  • How to fix the Assertion Failed error for Magelis HMIGTO/GTU series?

    This is a known issue and the PCR PEP0299618R has been created for that. This issue should be fixed in VJD V6.2 SP4.1   Pending the fix, please restore system operating system to the SD card with the backup/Restore tool and the OS image. After that, insert the SD card back to the HMI unit when it is turned off. Then power the unit back on, the operating system should be restored automatically from the SD card. Please refer the attached file for an example.          Ba...
    Read more

User guide
  • file image Magelis GTU - HMIDT... Display Module, Quick Reference Guide (pdf) download image`
  • file image Magelis GTU, User Manual (pdf) download image`
  • file image HRB78718 - HMIG.U. Box Module, Quick Reference Guide (pdf) download image`
Catalogue
  • file image Magelisâ„¢ GTU Universal Panels (pdf) download image`
Brochure
  • file image Innovative energy-efficient solutions to power containerships owned by Hamburg Sud (pdf) download image`
  • file image Innovative energy-efficient solutions to power containerships owned by Hamburg Sud (pdf) download image`
Instruction sheet
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
  • file image HMIZDCOV. Plastic Covers for Harsh Environments, Instruction Sheet (pdf) download image`
Certificate
  • file image HazLoc_cUL_NRAG7.E486185 _ALL_JUL2018 (pdf) download image`
  • file image HazLoc_UL_NRAG.E486185 _ALL_JUL2018 (pdf) download image`
  • file image ATEX_IECEx_HMIGTU_DID (pdf) download image`
  • file image ATEX_IECEx_HMIGTU_DID (pdf) download image`
Declaration of conformity
  • file image DCC_HMIGTU_DID_SEP2017 (pdf) download image`
End of life manual
  • file image HMIG3U,5U Open box for universal Panel, Product End-of-Life Instructions (pdf) download image`
Marine certificate
  • file image CCS_Marine Certificate_HMIGTU_DID (pdf) download image`
  • file image DNVGL_TAA00001A3_HMIGTU_IDISP (pdf) download image`
Product environmental
  • file image HMIG3U,5U Open box for universal Panel, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image Premium BOX for Universal Panel (pdf) download image`
RoHs Declaration
  • file image Premium BOX for Universal Panel (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech