ETB1EM16EPP0

$1,603.60
Special Order-Generally ships in 14 to 21 Business Days
SKU
ETB1EM16EPP0

Modicon ETB - Block 16 Input Modbus TCP/IP

Main
Range of product
Modicon ETB
Product or component type
I/O distributed module
Number of input channels
16
Module type
Modbus TCP/IP
Complementary
Input type
Contact
Input logic
Positive
Delay response
2.5 ms
Output current
2 A per module

8 A per output
Output protection type
Against short-circuits
Switching frequency
200 Hz
Short-circuit current
6.5 A
[Us] rated supply voltage
24 V DC
Connector type
M12
Standards
IEC 60529

IEC 60068-2-8
Environment
IP degree of protection
IP67
Ambient air temperature for operation
> -25...70 °C
Ambient air temperature for storage
> -40...85 °C
Vibration resistance
10 gn
Offer Sustainability
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
Product environmental profile
Available
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:ETB1EM16EPP0

   Frequently Asked Questions and Answers


  • Reverse PID mode in Modicon M241/M251

    There is no input to select between direct/inverse direction at the PID function block from the Util library. The FB_PID function block (Toolbox library) is from Schneider and has additional features. With FB_PID function block from the Toolbox library in SoMachine to change the regulation direction user can use negative P-factor (i_rKp) The basic PID function must remain the same.
    Read more

  • Can we use 800 IOs with Modicon m580 Safety System without impact TUV certification

    There is no issue to use 800 series IOs without any impact on TÜV certificate on a M580 Safety configuration. As a general rule, all of Remote Distributed equipments on Ethernet allowed in M580 system could be considered as “non-interfering” for Safety M580 modules. However, of course, 800 series IOs data are not supposed to be used to perform safety functions.
    Read more

  • Video: Setting Persistent Variables with the Modicon M221 in SoMachine Basic

    The video demonstrates how to set up persistent variables and save them in the memory words of SoMachine Basic.  
    Read more

  • Video: Creating IODDTs for Modicon m340 I/O Modules via Unity Pro

     The attached video will illustrate creating 3 IODDTs for an M340 IO module: One for the Module health itself. One for Channel 0 using T_DIS_OUT_GEN which has two components. One for Channel 1 using T_DIS_OUT_STD which has 22 components.  
    Read more

  • Can I tell what the Modbus Plus address of my Modicon PLC is via 984 ladder logic?

    Yes, the contents of the address configured in node 2 of the MSTR Instruction Function Code #3 (Get Local Statistics) will give you the Modbus Plus Network address of the PLC. Below is a example of a MSTR Instruction using Function Code #3 (Get Local Statistics) to get the Modbus Plus address of the PLC 400001 = 3 (Operation Type) 400003 = 1 (length) 400004 = 2 (Offset) 400010 = 2 (Network address of this station)
    Read more

User guide
  • file image Advantys ETB - IP67 Ethernet Block I/O Modules for Modbus TCP/IP, User Guide (pdf) download image`
Catalogue Page
  • file image Advantys ETB IP67 I/O modules (pdf) download image`
Certificate
  • file image UL_E327764_NMTR_NMTR7_FEB2017 (pdf) download image`
  • file image UL_E327764_NMTR_NMTR7_FEB2017 (pdf) download image`

Dimensions Drawings

Dimensions





Connections and Schema

I/O Assignments

Select the number of inputs/outputs according to the product characteristics in order to get the I/O assignment.





Power Connectors



1
output power (24V)
2
module/input power (24V)
3
module/input power (0V)
4
output power (0V)


2-Input Port
IEC Wiring Diagram with 2 Sensors





© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech