BCPMB042S

$7,252.91
Special Order-Generally ships in 14 to 21 Business Days
SKU
BCPMB042S

BCPM power monitoring intermediate - 42 solid core 100 A - 19 mm CT spacing

Main
Range
PowerLogic
Product name
PowerLogic BCPM
Product or component type
Multi-circuit energy meter
Device short name
BCPMB
Variant
Intermediate
Power monitoring
Basic instrumentation
Energy management
Sub billing and cost allocation
Device application
Sub billing
Power quality analysis
Voltage sag and swell detection
Type of measurement
Voltage

Current

Frequency

Active power

Power factor

Active energy
[Us] rated supply voltage
90...277 V, AC, 50/60 Hz +/- 1 %
Network frequency
50 Hz

60 Hz
Complementary
Analogue input type
Solid core CT, 100 A x 42
Update time
1.8 s
Measurement voltage
90...277 V phase to neutral

150...480 V phase to phase
Measurement accuracy
2 % branch current 0.25…2 A

1 % branch current 2…100 A

3 % mains current 1…100 %

3 % mains current 2…100 %

1 % voltage 90…277 V
Sampling rate
256 samples/cycle
Connection pitch
19 mm
Provided equipment
42 x current transformer

2 x cables
Communication port protocol
Modbus RTU
Communication port support
RS485
Communication of data
Over voltage alarm

Under voltage alarm

High-high current alarm

High current alarm

Low current alarm

Low-low current alarm
Environment
Mounting mode
Panel-mounted
Mounting support
Enclosure

Panel
Relative humidity
95 % between 0...60 °C
Ambient air temperature for storage
-40...70 °C
Operating altitude
3000 m
Standards
EN 61010

IEC 61036

UL 508

ANSI C12.1
Product certifications
UL
Width
288 mm
Height
146 mm
Product weight
1.5 kg
Offer Sustainability
RoHS (date code: YYWW)
Will not be compliant
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:BCPMB042S

   Frequently Asked Questions and Answers


  • Where can I find out more information about the Powerlogic Branch Circuit Monitoring?

    Issue General information and guides for the Powerlogic Branch Circuit Power Meter (BCPM) product line are required. Product Line Powerlogic BCPM, BCPME Environment BCPM Documentation Resolution The Branch Circuit Monitoring System consists of a main board and up to 84 branch circuit CTs. The CTs can either be solid-core CTs assembled onto a long PCB Board or individual split-core CTs. For more information about product selection, installation, and function, feel free to explore the attached documents....
    Read more

  • Branch Circuit Power Meter (BCPM) or Branch Circuit Power Meter Split Core (BCPMSC) read zero current for all CTs

    Goals and Symptoms Symptoms The PowerLogic BCPM or BCPMSC shows 0A on every circuit, even though the panel the meter is monitoring has a load. The meter has been installed correctly and all CT connections are made. Causes and Fixes Cause If the ribbon cables are reseated while the BCPM is on, the unit will not register current. The BCPM does a discovery of the ribbon cables only upon bootup. If the ribbon cables are reseated or seated after bootup, the BCPM will not detect the current. Resolutio...
    Read more

  • ION Setup Revision History and Features & Fixes

    Issue The ION Setup revision history may be required. Product Line ION Setup Environment ION Setup Resolution Please see the table below for the revision history.  To obtain the latest version of ION Setup software, refer to article FA212816 - Where can I download the latest version of ION Setup Software?   Release Date Version File Name Bug Fixes New Features 6/21/2013 ION 3.0 Build 13172 IONSETUP30_B13172_01.EXE - CM3/CM4 Alarm log programming to a depth of 0 - PM53xx Meter Reset...
    Read more

  • What device types are natively supported and compatible in ION Setup 3.0?

    Issue A list of devices supported and / or compatible in the most recent version of ION Setup 3.0. Product Line ION Setup version 3.0.17073.01 Environment Supported Device types and compatiblity with ION Setup software Cause The posted ION Setup user manual is not updated as frequently as new software versions are released. The manual states that, “The devices supported by ION Setup are subject to change”. Resolution UPDATED 3/16/2017 The list below indicates devices that ar...
    Read more

  • What are the part numbers for the BCPM (BCPME) with ethernet?

     Issue   Schneider Electric is pleased to announce the newest member of the PowerLogic Branch Circuit Power Meter (BCPM) series, the BCPM”E” with Ethernet communications.  This version offers the widest range of communications options:  SNMP, BACnet IP and Modbus TCP via Ethernet, and Modbus RTU or BACnet MS/TP via the RS-485 serial network port.  It is capable of communicating Modbus protocol simultaneously with SNMP or BACnet for integration flexibility without gate...
    Read more

Catalogue
  • file image PowerLogic Selection Guide - Print Version (pdf) download image`
  • file image PowerLogic Selection Guide - Web Version (pdf) download image`
  • file image PowerLogic Catalogue - 266 pages - Print File (NO PRINTED VERSION AVAILABLE) (pdf) download image`
  • file image PowerLogic Catalog - 266 pages Web (NO PRINTED VERSION AVAILABLE) (pdf) download image`
Firmware - Released
  • file image E30_1.026-180207-120450 Firmware Release for BCPM (fw) download image`
Technical leaflet
  • file image BCPM Technical Dataseet - Print Version (pdf) download image`
  • file image BCPM Technical Dataseet - Web Version (pdf) download image`
Catalogue Page
  • file image TI current transformers (pdf) download image`
RoHs Declaration
  • file image BCPM power monitoring intermediate - 42 solid core 100 A - 19 mm CT spacing (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech