soft starter for asynchronous motor - ATS01 - 9 A - 110..480V - 1.1..4 KW

Main
Range of product
Altistart 01
Product or component type
Soft starter
Product destination
Asynchronous motors
Product specific application
Simple machine
Device short name
ATS01
Network number of phases
1 phase
[Us] rated supply voltage
110...480 V - 10...10 %
Motor power kW
4 kW 3 phases 400 V

1.5 kW 3 phases 230 V

1.1 kW 1 phase 230 V
Motor power hp
1 hp 3 phases 210 V

2 hp 3 phases 230 V

5 hp 3 phases 460 V
IcL starter rating
9 A
Utilisation category
AC-53B EN/IEC 60947-4-2
Current consumption
45 A at nominal load
Type of start
Start with voltage ramp
Power dissipation in W
1 W at full load and at end of starting

46 W in transient state
Complementary
Assembly style
With heat sink
Function available
Integrated bypass
Supply voltage limits
99...528 V
Supply frequency
50...60 Hz - 5...5 %
Network frequency
47.5...63 Hz
Output voltage
<= power supply voltage
[Uc] control circuit voltage
24 V AC/DC +/- 10 % 30 mA

110 V AC +/- 10 % 35 mA

240 V AC +/- 10 % 80 mA
Starting time
1 s 100

5 s 20

Adjustable from 1 to 5 s
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete output current
2 A DC-13

3 A AC-15
Tightening torque
0.5 N.m

1.9...2.5 N.m
Electrical connection
4 mm screw clamp terminal rigid 1 1...10 mm² AWG 8 power circuit

Screw connector rigid 1 0.5...2.5 mm² AWG 14 control circuit

4 mm screw clamp terminal rigid 2 1...6 mm² AWG 10 power circuit

Screw connector rigid 2 0.5...1 mm² AWG 17 control circuit

Screw connector flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit

4 mm screw clamp terminal flexible without cable end 1 1.5...10 mm² AWG 8 power circuit

Screw connector flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit

4 mm screw clamp terminal flexible with cable end 2 1...6 mm² AWG 10 power circuit

4 mm screw clamp terminal flexible without cable end 2 1.5...6 mm² AWG 10 power circuit

Screw connector flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
Marking
CE
Operating position
Vertical +/- 10 degree
Height
124 mm
Width
45 mm
Depth
131 mm
Product weight
0.28 kg
Compatibility code
ATS01N1
Power range
2.2...3 kW at 200...240 V 3 phases

4...6 kW at 380...440 V 3 phases

1.1...2 kW at 200...240 V 1 phase
Motor starter type
Soft starter
Environment
Electromagnetic compatibility
Damped oscillating waves level 3 IEC 61000-4-12

Electrostatic discharge level 3 IEC 61000-4-2

Immunity to electrical transients level 4 IEC 61000-4-4

Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3

Voltage/current impulse level 3 IEC 61000-4-5

Conducted and radiated emissions level B CISPR 11

Conducted and radiated emissions level B IEC 60947-4-2

EMC immunity EN 50082-2

Harmonics IEC 1000-3-2

Harmonics IEC 1000-3-4

Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6

Micro-cuts and voltage fluctuation IEC 61000-4-11

EMC immunity EN 50082-1
Standards
EN/IEC 60947-4-2
Product certifications
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal

CCC

CSA

C-Tick

GOST

UL
IP degree of protection
IP20
Pollution degree
2 EN/IEC 60947-4-2
Vibration resistance
1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6

1 gn 13...150 Hz EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5...95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient air temperature for operation
-10...40 °C without derating

40...50 °C with current derating of 2 % per °C
Ambient air temperature for storage
-25...70 °C EN/IEC 60947-4-2
Operating altitude
<= 1000 m without derating

> 1000 m with current derating of 2.2 % per additional 100 m
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:ATS01N109FT

   Frequently Asked Questions and Answers


  • Which power phases are controlled by Altistart 01 Soft-Starter?

    The power phases that are controlled by Altistart 01 Soft-Starter are as follows: In N1 Range of Altistart 01 Soft-Starter only 1 Phase is controlled and that is L1, L2 and L3 are uncontrolled.   In N2 Range of Altistart 01 Soft-Starter only 2 Phases are controlled and that is L2 and L3, L1 is uncontrolled.
    Read more

  • Do the Altistart 01 soft-starters have any available spare parts?

    Issue: Do the Altistart 01 soft-starters have any available spare parts? Product Line: Altistart 01 Environment: All serial numbers for Altistart 01 Cause: N/A Resolution: There are no spare parts available for the Altistart 01 soft-starters
    Read more

  • What are the dimensions for the ats01n230ly and ats01n244ly?

    Issue: What are the dimensions for the ATS01N230LY and ATS01N244LY? Product Line: Altistart 01 Environment: All Cause: N/A Resolution: Both units have the same dimensions: 4.96 (126 mm) inches deep 5.75 (146 mm) inches tall 7.09 (180 mm) inches wide
    Read more

  • Does the ats01 softstart require external thermal overload protection?

    Issue: Does the ATS01 softstart require external thermal overload protection?  Product Line: ATS01, Altistart 01 Environment: All Cause: N/A Resolution: The ATS01 softstart does require an external overload thermal protection for the motor.  It also requires a starter or a contactor to be used at the line of the softstart. 
    Read more

  • What is the replacement for the High HP ats01n softstarters?

    Issue: Wants to order the ATS01N230LY, ATS01N244LY, ATS01N272LY or ATS01N285LY Product line: ATS01, Altistart 01, High HP Environment: All models Cause: The launch of the ATS22 in 2011 caused the High HP units to become redundant. Resolution: The ATS01 High HP units were replaced with the ATS22 units.  These are functional replacements only.  The ATS01 had no overload protection, an internal power supply and simple dial adjustments.  The ATS22 will require external 120V or 230V po...
    Read more

Catalogue
  • file image Catalog: Soft starters Altistart 01 (pdf) download image`
Instruction sheet
  • file image Instruction Sheet - ATS01N1...FT (pdf) download image`
CAD
  • file image Soft starter Power : 1.1 to 1.5 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwf) download image`
  • file image Soft starter Power : 1.1 to 1.5 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwg) download image`
  • file image Soft starter Power : 1.1 to 1.5 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dxf) download image`
  • file image Soft starter Power : 1.1 to 1.5 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (wmf) download image`
Certificate
  • file image E184727 UL GENERIC CERTIFICATES (pdf) download image`
  • file image ATS01 EU DECLARATION (pdf) download image`
  • file image ATS01 C-TICK certificate of conformity (pdf) download image`
  • file image ATS01 CSA CERTIFICATE (pdf) download image`
End of life manual
  • file image ALTISTART 01, 0.75 – 15 kW, Product End-of-Life Instructions (pdf) download image`

Dimensions Drawings

Dimensions
Mounting on Symetrical (35 mm) Rail



Screw Fixing



(1)
Retractable fixings


Connections and Schema

Example of 3-phase Power Supply Connection



(1)
A line contactor must be used in the sequence.
A1 :
Soft starter
Q1 :
Motor circuit-breaker
KM1 :
Contactors
F1, F2 :
Control protection fuses
S1, S2 :
Pushbuttons


Technical Description

Function Diagram



Us :
Power supply voltage
Uc :
Control supply voltage
LED 1 :
Green LED
LED 2 :
Yellow LED
Um :
Motor voltage


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech