ATS01N103FT

Generally ships in 1 or 2 days
SKU
ATS01N103FT

soft starter for asynchronous motor - ATS01 - 3 A - 110..480V - 0.55..1.1 KW




Main
Range of product
Altistart 01
Product or component type
Soft starter
Product destination
Asynchronous motors
Product specific application
Simple machine
Device short name
ATS01
Network number of phases
1 phase
[Us] rated supply voltage
110...480 V - 10...10 %
Motor power kW
0.37 kW 3 phases 230 V

0.55 kW 3 phases 230 V

1.1 kW 3 phases 400 V

0.37 kW 1 phase 230 V
Motor power hp
0.5 hp 3 phases 230 V

0.5 hp 3 phases 460 V

1.5 hp 3 phases 460 V
IcL starter rating
3 A
Utilisation category
AC-53B EN/IEC 60947-4-2
Current consumption
15 A at nominal load
Type of start
Start with voltage ramp
Power dissipation in W
19 W in transient state

4 W at full load and at end of starting
Complementary
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete output current
2 A DC-13

3 A AC-15
Tightening torque
0.8 N.m
Electrical connection
Cage type connector rigid 1 2.5 mm² AWG 14 control circuit

Cage type connector rigid 1 2.5 mm² AWG 14 power circuit

Cage type connector rigid 2 1 mm² AWG 17 control circuit

Cage type connector rigid 2 1 mm² AWG 17 power circuit

Cage type connector flexible with cable end 1 2.5 mm² AWG 14 control circuit

Cage type connector flexible with cable end 1 2.5 mm² AWG 14 power circuit

Cage type connector flexible without cable end 1 2.5 mm² AWG 14 control circuit

Cage type connector flexible without cable end 1 2.5 mm² AWG 14 power circuit

Cage type connector flexible with cable end 2 0.75 mm² AWG 18 control circuit

Cage type connector flexible with cable end 2 0.75 mm² AWG 18 power circuit

Cage type connector flexible without cable end 2 1 mm² AWG 17 control circuit

Cage type connector flexible without cable end 2 1 mm² AWG 17 power circuit
Marking
CE
Operating position
Vertical +/- 10 degree
Height
100 mm
Width
23 mm
Depth
100 mm
Product weight
0.16 kg
Compatibility code
ATS01N1
Power range
0...0.5 kW at 200...240 V 1 phase

0...0.5 kW at 200...240 V 3 phases

0.55...1 kW at 200...240 V 3 phases

1.1...2 kW at 380...440 V 3 phases
Motor starter type
Soft starter
Assembly style
With heat sink
Function available
Integrated bypass
Supply voltage limits
99...528 V
Supply frequency
50...60 Hz - 5...5 %
Network frequency
47.5...63 Hz
Output voltage
<= power supply voltage
[Uc] control circuit voltage
110 V AC +/- 10 % 30 mA

24 V AC/DC +/- 10 % 25 mA

240 V AC +/- 10 % 65 mA
Starting time
1 s 100

5 s 20

Adjustable from 1 to 5 s
Environment
Electromagnetic compatibility
Damped oscillating waves level 3 IEC 61000-4-12

Electrostatic discharge level 3 IEC 61000-4-2

Immunity to electrical transients level 4 IEC 61000-4-4

Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3

Voltage/current impulse level 3 IEC 61000-4-5

Conducted and radiated emissions level B CISPR 11

Conducted and radiated emissions level B IEC 60947-4-2

EMC immunity EN 50082-2

Harmonics IEC 1000-3-2

Harmonics IEC 1000-3-4

Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6

Micro-cuts and voltage fluctuation IEC 61000-4-11

EMC immunity EN 50082-1
Standards
EN/IEC 60947-4-2
Product certifications
B44.1-96/ASME A17.5 for starter wired to the motor delta terminal

CCC

CSA

C-Tick

GOST

UL
IP degree of protection
IP20
Pollution degree
2 EN/IEC 60947-4-2
Vibration resistance
1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6

1 gn 13...150 Hz EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5...95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient air temperature for operation
-10...40 °C without derating

40...50 °C with current derating of 2 % per °C
Ambient air temperature for storage
-25...70 °C EN/IEC 60947-4-2
Operating altitude
<= 1000 m without derating

> 1000 m with current derating of 2.2 % per additional 100 m
Contractual warranty
Warranty period
18 months
Loading...
  • Does the ats01 come with a shorting contactor?

    Issue:
    Does the ATS01 come with a shorting contactor?

    Product Line:
    Altistat 01

    Environment:
    All

    Cause:
    N/A

    Resolution:
    All of the ALTISTART 01 models, except the ATS01N103FT and ATS01N106FT, have an internal shorting contactor as standard.

  • Which power phases are controlled by Altistart 01 Soft-Starter?

    The power phases that are controlled by Altistart 01 Soft-Starter are as follows:

    In N1 Range of Altistart 01 Soft-Starter only 1 Phase is controlled and that is L1, L2 and L3 are uncontrolled.
     
    In N2 Range of Altistart 01 Soft-Starter only 2 Phases are controlled and that is L2 and L3, L1 is uncontrolled.

  • Do the Altistart 01 soft-starters have any available spare parts?

    Issue:
    Do the Altistart 01 soft-starters have any available spare parts?

    Product Line:
    Altistart 01

    Environment:
    All serial numbers for Altistart 01

    Cause:
    N/A

    Resolution:
    There are no spare parts available for the Altistart 01 soft-starters

  • What are the dimensions for the ats01n230ly and ats01n244ly?

    Issue:
    What are the dimensions for the ATS01N230LY and ATS01N244LY?

    Product Line:
    Altistart 01

    Environment:
    All

    Cause:
    N/A

    Resolution:
    Both units have the same dimensions:
    4.96 (126 mm) inches deep
    5.75 (146 mm) inches tall
    7.09 (180 mm) inches wide

  • Does the ats01 softstart require external thermal overload protection?

    Issue:
    Does the ATS01 softstart require external thermal overload protection? 

    Product Line:
    ATS01, Altistart 01

    Environment:
    All

    Cause:
    N/A

    Resolution:
    The ATS01 softstart does require an external overload thermal protection for the motor.  It also requires a starter or a contactor to be used at the line of the softstart. 

Write Your Own Review
You're reviewing:ATS01N103FT
Catalogue
  • file image Catalog: Soft starters Altistart 01 (pdf) download image`
Instruction sheet
  • file image Instruction Sheet - ATS01N1...FT (pdf) download image`
CAD
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwf) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwg) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dxf) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (wmf) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwf) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dwg) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (dxf) download image`
  • file image Soft starter Power : 0.37 to 0.75 kW - U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V (wmf) download image`
Certificate
  • file image E184727 UL GENERIC CERTIFICATES (pdf) download image`
  • file image ATS01 EU DECLARATION (pdf) download image`
  • file image ATS01 C-TICK certificate of conformity (pdf) download image`
  • file image ATS01 CSA CERTIFICATE (pdf) download image`
End of life manual
  • file image ALTISTART 01, 0.75 – 15 kW, Product End-of-Life Instructions (pdf) download image`

Dimensions Drawings

Dimensions
Mounting on Symetrical (35 mm) Rail or Asymetrical Rail with Adaptor RHZ 66





Connections and Schema

Example of 3-phase Power Supply Connection



(1)
A line contactor must be used in the sequence.
A1 :
Soft starter
Q1 :
Motor circuit-breaker
KM1 :
Contactors
F1, F2 :
Control protection fuses
S1, S2 :
Pushbuttons


Technical Description

Function Diagram



Us :
Power supply voltage
Uc :
Control supply voltage
LED 1 :
Green LED
LED 2 :
Yellow LED
Um :
Motor voltage


© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech