28102

$984.94
Special Order-Generally ships in 14 to 21 Business Days
SKU
28102

CIRCUIT BREAKER IEC 25A NEH MAG TRIP

Main
Range of product
NS80H-MA
Product or component type
Circuit breaker
Device short name
Compact NS80H
Circuit breaker name
Compact NS80H
Device application
Motor
Poles description
3P
Protected poles description
3t
Network type
AC
Network frequency
50/60 Hz
[In] rated current
80 A ( 65 °C )
[Ui] rated insulation voltage
750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code
H
Breaking capacity
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

25 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2

6 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2

10 kA at 600 V AC 50/60 Hz conforming to NEMA AB1

100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1

65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1
[Ics] rated service breaking capacity
Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2

Ics 25 kA 500 V AC 50/60 Hz conforming to IEC 60947-2

Ics 25 kA 525 V AC 50/60 Hz conforming to IEC 60947-2

Ics 6 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2

Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2

Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation
Yes conforming to IEC 60947-2
Utilisation category
Category A
Trip unit name
MA
Trip unit technology
Magnetic
Trip unit rating
25 A
Protection type
Short-circuit protection (magnetic)
Pollution degree
3 conforming to IEC 60947
Complementary
Control type
Toggle
Mounting mode
Fixed
Mounting support
Backplate
Upside connection
Tunnel terminal
Downside connection
Tunnel terminal
Mechanical durability
20000 cycles
Electrical durability
10000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2

7000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2
Local signalling
Positive contact indication
Instantaneous pick-up adjustment type Ii
Adjustable
Instantaneous pick-up adjustment range
6...14 x In
Zone selective interlocking ZSI
Without
Earth-leakage protection
Without
Height
120 mm
Width
90 mm
Depth
80 mm
Environment
Standards
IEC 60947-2
Product certifications
ASEFA

ASTA

KEMA

LCIE
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to EN 50102
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-50...85 °C
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:28102

   Frequently Asked Questions and Answers


  • ETSNZ - What control voltages are available for Compact/Masterpact automatic source changeovers?

    In New Zealand we only offer 400V control for our automatic source changeovers.
    Read more

  • What is the Modbus port pinout for the Compact PC-E984-241 PLC?

    Please see attached Modbus port pinout. ASW952012.bmp  
    Read more

  • How do I add support to Concept for the Compact BVIC and BVRC I/O modules?

    A Modconnect .MDC file must be loaded through Concept's ModConnect Tool to add support for these modules. Go to IANET or the Schneider Services (Eclipse) websites and choose Software - Concept - Resolutions to download the necessary files. Follow the installation instructions. Legacy KB System (APS) Data: RESL163988 V1.0, Originally authored by on , Last Edited by on Related ranges: Concept
    Read more

  • How can I lock the direct rotary handle on a Compact ns400 / ns630 circuit-breaker?.

    The direct rotary handle can either be locked with padlocks or a keylock. Locking with Padlocks: Up to three padlocks can be fitted. The shackle diameter must be between 5 to 8mm. Locking with a keylock: Install: a keylock adaptor (without lock), part number 32604, and either a Ronis lock, part number 41940 or a Profalux lock 42888 The locks have random key numbers and come complete with two keys.
    Read more

  • Why does the display light of Micrologic 6.2 trip unit of Compact NSX not glow even when the load reading is displayed.

    Unlike other range of Micrologic the backlighting or display light of Micrologic 6.2 is not self powered by the primary current.   A separate external 24VDC power supply is required for the working of the backlight of Micrologic 6.2. For this, 24VDC power supply connector (LV434210) has to be used.   1.jpg
    Read more

Instruction sheet
  • file image Compact NS80H-MA - Circuit Breaker (pdf) download image`
CAD
  • file image CIRCUIT BREAKER IEC 25A NEH MAG TRODA_IP (pdf) download image`
  • file image CIRCUIT BREAKER IEC 25A NEH MAG TRODA_IP (stp) download image`
Certificate
  • file image CB-Certificate-Compact NS80H MA (pdf) download image`
End of life manual
  • file image End-of-Life Instructions Compact NS80H MA (pdf) download image`
Product environmental
  • file image PEP COMPACT NS80H-MA (pdf) download image`
© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech