170ADM39010

$2,371.07
Special Order-Generally ships in 14 to 21 Business Days
SKU
170ADM39010

discrete I/O module Modicon Momentum - 16I / 12O solid state

Main
Range of product
Modicon Momentum automation platform
Product or component type
Discrete solid state I/O base DC
Group of channels
1 group of 16 inputs

1 group of 4 outputs

1 group of 8 outputs
Discrete input number
16 IEC 1131-2 Type 1
Discrete input logic
Positive
Discrete input voltage
24 V DC
Discrete output number
12
Discrete output type
Solid state switch
Discrete output voltage
<= 30 V DC

24 V DC
Discrete output logic
Positive
Protective treatment
TC
Complementary
[Us] rated supply voltage
24 V DC
Input voltage limits
- 3...30 V
Voltage state 0 guaranteed
-3...5 V
Voltage state 1 guaranteed
11...30 V
Current state 0 guaranteed
<= 1.2 mA
Current state 1 guaranteed
>= 2.5 mA

6 mA 24 V
Input resistance
4 kOhm
Discrete output current
4 A per group of 8 outputs

2 A per group of 4 outputs

8 A per module

0.5 A per point
Leakage current
< 1 mA 24 V output circuit
Fault type
Broken wire on input circuit

Overload on output
Response time
< 0.1 ms from state 0 to state 1 on output

< 0.1 ms from state 1 to state 0 on output

2.2 ms from state 0 to state 1 on input

3.3 ms from state 1 to state 0 on input
Isolation between channels and bus
500 V AC
Power dissipation
<= 10 W

6.5 W
Marking
CE
Terminals description PLC n°1
(1)IN_DIS#1

(10)IN_DIS#10

(11)IN_DIS#11

(12)IN_DIS#12

(13)IN_DIS#13

(14)IN_DIS#14

(15)IN_DIS#15

(16)IN_DIS#16

(2)IN_DIS#2

(3)IN_DIS#3

(4)IN_DIS#4

(5)IN_DIS#5

(6)IN_DIS#6

(7)IN_DIS#7

(8)IN_DIS#8

(9)IN_DIS#9

(L+)PW_POS

(M-)PW_NEG

TB
Terminals description PLC n°2
(1)OUT_DIS#1

(10)OUT_DIS#10

(11)OUT_DIS#11

(12)OUT_DIS#12

(1L+)PW_POS

(2)OUT_DIS#2

(2L+)PW_POS

(3)OUT_DIS#3

(4)OUT_DIS#4

(5)OUT_DIS#5

(6)OUT_DIS#6

(7)OUT_DIS#7

(8)OUT_DIS#8

(9)OUT_DIS#9

TB_1
Current consumption
180 mA 24 V DC
Depth
47.5 mm
Height
141.5 mm
Width
125 mm
Product weight
0.26 kg
Environment
Product certifications
CSA

FM Class 1 Division 2

UL
Resistance to electrostatic discharge
4 kV contact IEC 801-2

8 kV on air IEC 801-2
Resistance to electromagnetic fields
10 V/m 80...1000 MHz IEC 801-3
Ambient air temperature for operation
0...60 °C
Ambient air temperature for storage
-40...85 °C
Relative humidity
95 % without condensation
Operating altitude
<= 5000 m
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Product Environmental Profile
Product end of life instructions
End of Life Information
Contractual warranty
Warranty period
18 months
Write Your Own Review
You're reviewing:170ADM39010

   Frequently Asked Questions and Answers


  • Which networks are supported on the Modicon Momentum by Communication adapters

    The following networks are supported by Modicon Momentum Communication adapters Communication adapters for Ethernet TCP/IP 170 ENT 110 02 Transparent Ready Class A10 170 ENT 110 01 Transparent Ready Class B20   INTERBUS SUPI 3 170 INT 110 03 Twisted Pair 170 INT 120 00 Fibre optic   INTERBUS I/O bus SUPI 2 170 INT 110 00 Twisted Pair   Profi bus DP 170 DNT 110 00 DeviceNet 170 LNT 710 00   Modbus Plus 170 PNT 110 20 170 PNT 160 20 170 NEF 110 21 170 NEF 160 21   Fipio 170 FNT 110...
    Read more

  • Where can I obtain technical support and information for Modicon Momentum PLCs?

    Documentation for Modicon Momentum PLCs can be found at the link below: Momentum PLC For technical support on Modicon Momentum PLCs please call 800-468-5342 option 1. Legacy KB System (APS) Data: RESL210194 V1.0, Originally authored by MaTh on 01/03/2013, Last Edited by MaTh on 01/03/2013 Related ranges: Other protocols
    Read more

  • dia6ed1040904en 3/2005 - Momentum Catalog Contains Incorrect M1E Processor Adapter Descriptions

    Goals and Symptoms The purpose of this resolution is to inform users of Momentum PRODUCTS that an error exists in the processor specifications of the Distributed I/O and Control Modicon Momentum flexible system for distributed I/O and control catalog, part number DIA6ED1040904EN, published 3/2005. Causes and Fixes In the 'Selection Guide' on page 8, the description for the M1E Processor Adapters, as shown in the following, is incorrect: The following table is the correct description of t...
    Read more

  • What is the transmission speed of data on a Momentum IObus network?

    Title Momentum IO bus network speed Issue   Product Line Modicon Momentum Environment IO Bus network Cause   Resolution Data is transmitted at 500 kbits/s on an IObus network.
    Read more

  • Can the Modbus port on the terminals of the 170adm54080 be used to program the Momentum CPU?

    Title 170ADM54080 Modbus port programming Issue   Product Line Modicon Momentum Environment   Cause   Resolution No, this port is a Modbus Master RS485 port designed to communicate to MCC (motor control center) devices which only have a small amount of data available.
    Read more

Instruction sheet
  • file image Momentum Communication Adapter Ground Screw Installation (pdf) download image`
Certificate
  • file image Hazloc_cCSAus_225844_70159012_Momentum_feb2018 (pdf) download image`
  • file image EAC_RUCFRME83B00168_MOMENTUM_DEC2014 (pdf) download image`
  • file image CSA_225844_2591646_MOMENTUM_AUG2017 (PDF) download image`
Declaration of conformity
  • file image DCC_MOMENTUM_JUL2016 (pdf) download image`
  • file image ACMA_RCM_MOMENTUM_AUG2013 (pdf) download image`
End of life manual
  • file image Modicon Momentum I/O base, Product End-of-Life Instructions (pdf) download image`
Product environmental
  • file image Modicon Momentum I/O base, Product Environmental Profile (pdf) download image`
REACh Declaration
  • file image discrete I/O module Modicon Momentum - 16I / 12O solid state (pdf) download image`
RoHs Declaration
  • file image discrete I/O module Modicon Momentum - 16I / 12O solid state (pdf) download image`

Dimensions Drawings

Standard Adapter on a Typical Base
Dimensions





Mounting and Clearance

Mounting on a Wall





Connections and Schema

External Wiring Diagrams
2-Wire Devices



3- and 4-Wire Devices





Internal Pin Connections

Rows 1 through 3 show the internal connections between terminals on the I/O base. Rows 4 through 5 show the internal connections on the optional busbar.





© 2018 Switchboard in a Box. All Rights Reserved. Design & Developed by Shaligram Infotech